/All Products
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4 - Data Sheet Spectrex 40/40L4 - User Guide Spectrex 40/40L4 - Accessories
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4B - Data Sheet Spectrex 40/40L4B - User Guide Spectrex 40/40L4B - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40LB - Data Sheet Spectrex 40/40LB - User Guide Spectrex 40/40LB - Accessories
    Details
  • Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories
    Details
  • Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories
    Details
  • Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Spectrex 40/40 Series - Accessories
    Details
  • Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) Non-sounder Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D
    Details
  • Protective cover helps prevent malicious or accidental false fire alarms. Surface mount (32mm spacer) 96 dB sounder (at 1 metre) Prevents false alarms, without hindering legitimate operation of a manual call point in the event of an emergency. Glows in the dark. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Polycarbonate tested -40°C (-40°F) to 49°C (120°F). 104 mm H x 96 mm W x 58 mm D
    Details
  • Protective cover helps prevent malicious or accidental damage to electrical switches and call points. Prevents unwanted or accidental use, without hindering legitimate operation of a manual call point in the event of an emergency. Spring loaded hinge mechanism. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Can accommodate flush or surface mounted applications. Polycarbonate tested -40°C (-40°F) to 49°C (120°F).
    Details
  • Protective cover helps prevent malicious or accidental damage to electrical switches and call points. Prevents unwanted or accidental use, without hindering legitimate operation of a manual call point in the event of an emergency. Spring loaded hinge mechanism. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Can accommodate flush or surface mounted applications. Polycarbonate tested -40°C (-40°F) to 49°C (120°F).
    Details
  • Protective cover helps prevent malicious or accidental damage to electrical switches and call points. Prevents unwanted or accidental use, without hindering legitimate operation of a manual call point in the event of an emergency. Spring loaded hinge mechanism. Tough polycarbonate housing can withstand the severest of knocks. A simple 4 fixing installation can retrofit over existing device. Can accommodate flush or surface mounted applications. Polycarbonate tested -40°C (-40°F) to 49°C (120°F).
    Details
  • Helps protect smoke detectors from vandalism and accidental damage. Models to fit virtually all smoke detectors available today. May be spray painted once prior to installation to match decor. Three-year guarantee against breakage in normal use. Steel Web Stoppers have corrosion resistant polyester coating Fast and easy installation. Simple removal for servicing detector. 175 mm H x 175 mm W x 75 mm D
    Details
  • Helps protect smoke detectors from vandalism and accidental damage. Models to fit virtually all smoke detectors available today. May be spray painted once prior to installation to match decor. Three-year guarantee against breakage in normal use. Steel Web Stoppers have corrosion resistant polyester coating Fast and easy installation. Simple removal for servicing detector. 180 mm H x 180 mm W x 115 mm D
    Details
  • Help to protect the operation of beacons and sounders from theft and vandalism. These steel cages are designed to protect beacons and sounders from vandalism and misuse. Constructed from plastic coated, heavy-duty galvanised steel rod. A simple 4 fixing point installation can retrofit over existing devices. Fast and easy installation. Simple removal for servicing of devices. 125d x 150dia
    Details
  • Key Features:; Supplied in packs of 10
    Details
  • Key Features:; Moulded from tough, clear UV-stabilised polycarbonate 87.8 mm H x 89.9 mm W x 36.8 mm D
    Details
  • Unique manual call point that mimics the feel of breaking glass whilst offering the user the benefits and environmental advantages of a resettable operating element. An indicator drops into view at the top of the window on activation. The unit is then simply reset with a key and is ready for re-use straight away. Extremely attractive, high value look and feel: glass appearance maintains operator deterrence, whilst a visible warning flag confirms activation. Easy installation due to no glass elements that could be broken or incorrectly fitted. Surface mounted, 20mm conduit entry points are provided for ease of installation. Operating temperature -20°C (-4°F) to 65°C (149°F). Fitted with a single pole changeover switch both the normally open and normally closed contacts are easily accessed through the installer terminals Comes with ‘Emergency’ label
    Details
  • Unique manual call point that mimics the feel of breaking glass whilst offering the user the benefits and environmental advantages of a resettable operating element. An indicator drops into view at the top of the window on activation. The unit is then simply reset with a key and is ready for re-use straight away. Extremely attractive, high value look and feel: glass appearance maintains operator deterrence, whilst a visible warning flag confirms activation. Easy installation due to no glass elements that could be broken or incorrectly fitted. Surface mounted, 20mm conduit entry points are provided for ease of installation. Operating temperature -20°C (-4°F) to 65°C (149°F). Fitted with a single pole changeover switch both the normally open and normally closed contacts are easily accessed through the installer terminals Comes with Smoke Vent label
    Details
  • Unique manual call point that mimics the feel of breaking glass whilst offering the user the benefits and environmental advantages of a resettable operating element. An indicator drops into view at the top of the window on activation. The unit is then simply reset with a key and is ready for re-use straight away. Extremely attractive, high value look and feel: glass appearance maintains operator deterrence, whilst a visible warning flag confirms activation. Easy installation due to no glass elements that could be broken or incorrectly fitted. Surface mounted, 20mm conduit entry points are provided for ease of installation. Operating temperature -20°C (-4°F) to 65°C (149°F). Fitted with a single pole changeover switch both the normally open and normally closed contacts are easily accessed through the installer terminals Comes with running man logo
    Details
  • Unique manual call point that mimics the feel of breaking glass whilst offering the user the benefits and environmental advantages of a resettable operating element. An indicator drops into view at the top of the window on activation. The unit is then simply reset with a key and is ready for re-use straight away. Extremely attractive, high value look and feel: glass appearance maintains operator deterrence, whilst a visible warning flag confirms activation. Easy installation due to no glass elements that could be broken or incorrectly fitted. Surface mounted, 20mm conduit entry points are provided for ease of installation. Operating temperature -20°C (-4°F) to 65°C (149°F). Call point that incorporates two independent single pole changeover switches providing double pole changeover contacts Comes with running man logo
    Details