Choice of tones on standard device: Apollo, Slow Whoop, and DIN IP66 rated Two Volume settings 92dB(A) and 100dB(A) Synchronisation of 'alert' and 'evacuate' tones Individual and group addressing Built in isolator -
Key Features: For use on an XP95 / Discovery system Sound output of 85dB(A) at 1 metre Current consumption of only 3mA Loop-powered Responds to signals from the associated detector ? does not have an address of its own Adjustable volume control IP23D rated -
For use on an XP95 / Discovery system Sound output of 85dB(A) at 1 metre Current consumption of only 3mA Loop-powered Responds to signals from the associated detector – does not have an address of its own Adjustable volume control IP23D rated -
Key Features: Visual indicator flash rate of once per second Synchronisation of visual indicator flash Individual and group addressing Unique visual indicator self-test Loop-powered Built-in Isolator -
Device Addressing:; Visual indicator flash rate of once per second Synchronisation of visual indicator flash Individual and group addressing Unique visual indicator self-test Loop-powered Built-in Isolator -
-
Key Features: Loop-powered Polarity sensitive Up to 20 detectors can be installed between isolators Allows fully isolated spurs -
Key Features: It can report fault, switch open and switch closed levels Three visible LEDs Capable of switching up to 8A at 250V AC Fits a standard 35mm DIN-Rail -
Key Features: Allows sounders to be operated continuously or be pulsed, 1 second on, 1 second off May be synchronised with loop sounders An opto-coupled input is provided to monitor the state of the external power supply Features group addressing Will accept a load of up to 5A -
Key Features: Loop-powered Visible short-circuit and alarm LEDs Built-in Isolator -
Key Features: Ideal in environments that are dirty or smoky under natural conditions Well suited for warehouses, loading bays and car-parks Unaffected by wind or atmospheric pressure -
Ideal in environments that are dirty or smoky under natural conditions Well suited for warehouses, loading bays and car-parks Unaffected by wind or atmospheric pressure -
Key Features: Ideal in environments that are dirty or smoky under normal conditions Well-suited to warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Other part codes include: AD-2002 -
Ideal in environments that are dirty or smoky under normal conditions Well-suited to warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure -
Robust design Waterproof Reports an alarm in under 0.2 seconds -
Key Features: Robust design Waterproof Reports an alarm in under 0.2 seconds -
Key Features: Rate of rise and fixed temperature alarm point. Single thermistor technology. Transient voltage protection. Resettable operation. Lockable security fitting. Please Note: Must be connected to a suitable safety barrier and protocol translator -
Rate of rise and fixed temperature alarm point. Single thermistor technology. Transient voltage protection. Resettable operation. Lockable security fitting. -
‘Plug and Play’ terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element -
Key Features: Plug and Play terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element -
Detects super heating and flaming combustibles. Dual chamber technology. Wind resistant smoke inlets. Transient voltage protection. Fine gauze insect protection. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator.; -20°C to +70°C (T5) -20°C to +45°C (T4) -20°C to +60°C -
Key Features: Detects super heating and flaming combustibles. Dual chamber technology. Wind resistant smoke inlets. Transient voltage protection. Fine gauze insect protection. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator. -
Reports an alarm in under 0.2 seconds Waterproof / weatherproof IP67 Designed for ‘explosive mixture’ atmosphere -
Key Features: Reports an alarm in under 0.2 seconds Waterproof / weatherproof IP67 Designed for ?explosive mixture atmosphere -
Key Features: Detects a wide range of fires. Insensitive to wind. Transient voltage protection. Fine gauze insect protection. Simple construction allows detection chamber to be cleaned. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator. Responds well to slowburning, smouldering fires Well-suited to escape routes Unaffected by wind or atmospheric pressure -
Detects a wide range of fires. Insensitive to wind. Transient voltage protection. Fine gauze insect protection. Simple construction allows detection chamber to be cleaned. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator. Responds well to slowburning, smouldering fires Well-suited to escape routes Unaffected by wind or atmospheric pressure -
Two tones Two volume ranges 55-75dB(A) and 75-91dB(A) Individual and group addressing Unique acoustic self-test Built-in isolator -
Operates in air speeds of 0.5m/s to 20m/s Transparent cover to view detector head LED Integral smoke test port -
Key Features: Operates in air speeds of 0.5m/s to 20m/s Transparent cover to view detector head LED Integral smoke test port -
Robust design Waterproof Reports an alarm in under 0.2 seconds -
Key Features: Robust design Waterproof Reports an alarm in under 0.2 seconds -
Ionisation technology - responds quickly to fast flaming fires LPCB and VdS approved CE marked Designed for use with the Firewatch single and two loop fire alarm panels Red LED alarm indicator Supply voltage: 17 to 28 Volts dc Operating temperature: -20°C to +70°C IP23D rating Please note: The Apollo XP95 detectors require an XPERT card mounting base or an XP95 Isolating base to operate with the Firewatch single and two loop addressable fire alarm panels -
Ionisation technology - responds quickly to fast flaming fires LPCB and VdS approved CE marked Designed for use with the Firewatch single and two loop fire alarm panels Red LED alarm indicator Supply voltage: 17 to 28 Volts dc Operating temperature: -20°C to +70°C IP23D rating Please note: The Apollo XP95 detectors require an XPERT card mounting base or an XP95 Isolating base to operate with the Firewatch single and two loop addressable fire alarm panels -
Key Features: High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle of visibility Enables DDA compliance Synchronised flash Can be used with Discovery or XP95 -
Key Features:; High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle of visibility Enables DDA compliance Synchronised flash Can be used with Discovery or XP95 -
Key Features: Provides a set of voltage free contacts controlled by the remote output of a detector. Draws negligible current Capable of switching up to 30V at 1A