Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54
-
-
Long term service and support Supports 1 MXDigital loop with 250 addresses 2 KM loop length 32 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 32 Zone Fully Functional Mains powered repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839
-
Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool.
-
Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
-
Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
-
PSB800 5A 24Vd.c. battery backed power supply and loop booster FIM801CV field interface PCB incorporating one MX DIGITAL loop CPU800 32 bit processor and memory Card XLM800 loop expansion card containing two MX Digital loops Optional remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
-
PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating two MX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card(s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists firefighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
-
The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC
-
-
Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S)
-
ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
-
Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Features; Manufactured to EN54 part 3 Integral sounder and detector base Volume and tone adjustable after installation Low Power Synchronisation Do not require use of a standard base (maybe installed directly onto a standard besa box)
-
Key Features:; Solar Blind for false alarm free operation Marine approved Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra-low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
-
Features:; Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Discrete ultra low profile design Fits a standard detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors; Infa-Red Flame Detector - Data Sheet
-
-
-
-
Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; High Performance Optical Smoke Detector - Data Sheet
-
-
-
-
-
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; CO & Rate Of Rise Heat Detector - Data Sheet
-
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22; Rate Of Rise Heat Detector - Data Sheet
-
-
-
-
Please Note: These units are only available as a Refusbished unit, please Contact Us for more Price & Availability.
-
-
Tyco MD611EX - Data Sheet
-
Communication and control interface to MZX-Technology Fire Controllers Approved to EN54-13 ensuring system compatibility Integrated short-circuit isolator removes the need of installing a separate short-circuit isolator Reduced installation costs Meets the requirements of EN54 Pt. 11 and EN54 Pt. 17. IP67 rating for outdoor installations Marine Approved