/All Products
  • a stand-alone base device using a separately available locking white cap (BF330CTLIDW) / red cap (BF330CTLIDR), or a combined base device and detector (detectors are separately available and wired on a separate detection circuit). The base devices are compatible with C-TEC’s range of ActiV conventional detectors and other compatible third-party suppliers.; Third-party certified to EN54-3 (Sounders) and EN54-23 (VADs). Provides 'C-3-8.5' light distribution (min 0.4 lux over a 3 x 8.5m cylindrical area). Impressive 96dB(A) sound output @ 1m. 31 selectable primary and secondary tone pairs and two volume levels (high and low) Three selectable VAD flash rates (0.5Hz, 1Hz, OFF) Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz) Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz) Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. Supplied with a BF431QCP quick connect plate and detector spur wires. IP21C rated.
    Details
  • Key Features:; Includes three selectable voice message pairs. Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area) using the same lenses and electronics as our EN54-23, 3 & 17 certified base sounder VAD. Onboard short-circuit loop isolator. 550µA quiescent current. 19.5mA alarm current @24V DC (VAD lit, voice sounder on max). Group addressing facility allows multiple devices to be operated simultaneously. 7 selectable volume levels. Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. IP21C rated. Detector spur wires included.
    Details
  • Key Features:; Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. IP21C rated.
    Details
  • Key Features:; Third-party certified to EN54-23 (VADs) and 17 (Isolators) by Intertek. Provides 'C-3-8' light distribution when ceiling mounted (min 0.4 lux over a 3 x 8m cylindrical area). Can also provide 'W-3-3.1' light distribution when wall mounted (min. 0.4 lux over a 2.4 x 3.5m cuboid area). Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. IP21C rated.
    Details
  • Key Features:; Provides 'C-3-8' light distribution (min 0.4 lux over a 3 x 8m cylindrical area). Supplied with a BF431QCP quick connect plate and detector spur wires. Onboard short-circuit loop isolator. 550µA quiescent current. 10mA alarm current @24V DC. Group addressing facility allows multiple devices to be operated simultaneously. Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use. IP21C rated.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF560-12/E Caged & BF560-12/C PCB-only versions available.
    Details
  • Key Features:; Metal base plate facilitates straightforward mounting inside third-party OEM enclosures. Includes a single-pole voltfree changeover relay that switches for any fault condition. Includes a fault type & hazardous voltages present LED. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF560-24/E caged & BF560-24/C PCB-only versions available.
    Details
  • Key Features:; Multiple indicators - supply present, general fault, fault type & aux. equipment fault. Two selectable battery charge currents. Battery fault impedance limits can be optimised to suit load current (helps extend battery life). Mains fail simulation mode. Improved on-board temperature sensor with optional remote sensor. Electronic functions comply with EN50131-6 grades 1-4 for security applications. BF562-1/E caged & BF562-1/C PCB-only versions available.
    Details
  • Key Features:; Allows the connection of up to eight CFP760 Repeaters (one CFP761 required per Main, all CFP760 repeaters include a CFP761 as standard) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • Key Features:; Up to 8 repeaters per CFP master Includes its own Mains power supply that requires its own standby battery supply Provides the user with access to all AL1 and AL2 functions Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM Attractive flush or surface mountable plastic lid and enclosure - no bezel required
    Details
  • Key Features:; BSI certified to EN54-13 (Fire detection and fire alarm systems, compatibility assessment of system components). Detects resistances down to 10 ohms. One required per BF354 interface board sounder circuit Measures 50mm x 26mm x 5mm with 100mm tail (can be be fitted inside or alongside the last device on the sounder circuit).
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • PCB mounts inside the CFP fire panel. Outputs are NOT designed to switch mains voltages.
    Details
  • Key Features:; Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote) and eight output per zone relays. PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal. Aux. fire relay is active in an alarm condition provided all relevant delays have expired. Remote relay is active during any Alarm Condition provided all relevant delays have expired. Output per zone relays will changeover when the corresponding zone is in alarm (subject to certain conditions - for full details refer to the instructions, downloadable below). Outputs are NOT designed to switch mains voltages.
    Details
  • Key Features:; Provides four panel-controlled volt free relay outputs (reset, fault, aux. fire and remote). PCB mounts inside the CFP fire panel. Reset relay is active during the panel’s reset cycle. Fault relay is active in any fault condition. This relay is failsafe and normally energised - if power is removed from the panel the relay will changeover to produce a fault signal. Aux. fire relay is active in an alarm condition provided all relevant delays have expired. Remote relay is active during any Alarm Condition provided all relevant delays have expired. Outputs are NOT designed to switch mains voltages.
    Details
  • Key Features; A bespoke alternative to standard metal conduit boxes. Simplifies the installation of C-TEC manufactured fire detector bases and base sounder/VADs on ceiling tiles, solid ceilings, wooden beams, etc. Can be mounted directly onto a surface or in recesses behind ceiling tiles and plasterboard. Multiple access wiring points and lots of working space. Features two anti-rotation spikes. Easy termination of 16mm or 20mm cable glands ivia side and rear drill-out cable entry points.
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Eight detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
    Details
  • Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction
    Details
  • Key Features:; Allows for 2 Detectors per System Controller Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire/Fault delay Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Transmitter can be powered from Controller
    Details
  • Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Approved to EN54:12 and UL268
    Details