/All Products
  • Low profile design Utilises digital CoreProtocol communications Compatible with Discovery and XP95 systems Integrated switchable isolator as standard 8-way DIL switch addressing Drift compensation FasTest for quicker testing Tricoloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 and EN 54-17 standards Locking mechanism (grub screw)
    Details
  • Dual heat sensors Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • Dual heat sensors Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • Dual heat sensors PureLight® optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • Dual heat sensors PureLight® optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • PureLight® optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • PureLight® optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol® communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest® for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw)
    Details
  • Ideal in environments that are dirty or smoky under natural conditions Well suited for warehouses, loading bays and car-parks Unaffected by wind or atmospheric pressure
    Details
  • Ideal in environments that are dirty or smoky under normal conditions Well-suited to warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure
    Details
  • Sensitive to a wide range of fires Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure
    Details
  • Ionisation technology - responds quickly to fast flaming fires LPCB and VdS approved CE marked Designed for use with the Firewatch single and two loop fire alarm panels Red LED alarm indicator Supply voltage: 17 to 28 Volts dc Operating temperature: -20°C to +70°C IP23D rating Please note: The Apollo XP95 detectors require an XPERT card mounting base or an XP95 Isolating base to operate with the Firewatch single and two loop addressable fire alarm panels
    Details
  • Ionisation technology - responds quickly to fast flaming fires LPCB and VdS approved CE marked Designed for use with the Firewatch single and two loop fire alarm panels Red LED alarm indicator Supply voltage: 17 to 28 Volts dc Operating temperature: -20°C to +70°C IP23D rating Please note: The Apollo XP95 detectors require an XPERT card mounting base or an XP95 Isolating base to operate with the Firewatch single and two loop addressable fire alarm panels
    Details
  • Alarm flag for fast alarm reporting Alarm address for fast location of alarm XPERT 7 Card addressing Electronics-free base Easy installation Elegant design; XP95, Discovery and CoreProtocol compatible Responds well to slowburning, smouldering fires Well-suited to bedrooms and escape routes Unaffected by wind or atmospheric pressure
    Details
  • Key Features:; Optical technology - responds quickly to slow smouldering fires LPCB and VdS approved CE marked Designed for use with the Firewatch singe and two loop fire alarm panels Self- extinguishing white polycarbonate case Unaffected by wind or atmospheric pressure Supply voltage: 17 to 28 Volts dc Operating temperature: -20°C to +60°C IP23D rating
    Details
  • 7-Segment display Remote test capabilities Remote signalling capabilities Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Polarity insensitive Full range including optical and multi sensors Full range of I/O units and accessories Isolator base EN54 and CPD certified VdS approved
    Details
  • Key Features:; Remote test capabilities Remote signalling capabilities Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Polarity insensitive Full range including optical and multi sensors Full range of I/O units and accessories Isolator base EN54, VdS and CPD approved
    Details
  • Optical smoke and heat detection Five modes of operation Independent control of detector modes Optical sensor with field exchangeable optical chamber Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Remote test capabilities Remote signalling capabilities Full range of sensors: optical and heat Full range of I/O units, MCPs and accessories
    Details
  • Remote test capabilities Remote signalling capabilities Field exchangeable optical chamber Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Full range of detectors available Full range of I/O units and accessories Isolator base EN54:7 and CPD certified
    Details
  • Soft addressed Integral short circuit isolator Single address Wide range of sensor types 360° visibility LED using lightpipe technology Drift compensation Removable detector chamber Aesthetically pleasing; Quick and simple to install Single "multi-mode" heat sensor Wide viewing angle for increased LED visibility Common mounting base Positive "lock" indication Discreet design for incorporation into any decor Easy to maintain/service
    Details
  • Soft addressed Integral short circuit isolator Single address Wide range of sensor types 360° visibility LED using lightpipe technology Drift compensation Removable detector chamber Aesthetically pleasing; Quick and simple to install Single "multi-mode" heat sensor Wide viewing angle for increased LED visibility Common mounting base Positive "lock" indication Discreet design for incorporation into any decor Easy to maintain/service
    Details
  • Soft addressed Integral short circuit isolator Single address Wide range of sensor types 360° visibility LED using lightpipe technology Drift compensation Removable detector chamber Aesthetically pleasing; Quick and simple to install Single "multi-mode" heat sensor Wide viewing angle for increased LED visibility Common mounting base Positive "lock" indication Discreet design for incorporation into any decor Easy to maintain/service
    Details
  • Up to 250 detectors per loop Protective optical chamber screen Robust coated electronics Extended service life Fire, isolate and fault LED indications
    Details
  • Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Multi stage alarms - pre alarm feature 7 sound patterns - plus off, 3 different volume settings - if using Sita Multipoint with integral sounder Auxiliary digital inputs and outputs are available at any Addressable Multipoint device Automatic continuous self calibration Addressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicing Maintenance is made easy with the unique disposable optical chamber, designed as a cost effective solution to cleaning and re-calibration
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Multiple fire detection modes FireClass digital detection algorithms CO fire detection technology Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Attention tones can be programmed either as a bell (on speech variants) or a choice of 12 standard tones Soft’ start option Uniform sound distribution Low current consumption Fully synchronised sound patterns via the panel Selectable speech messages available to suit most requirements – switched on/off by the Vigilon panel Rich harmonic sound output using patented technique Options for sound output: Standard mode = 90 dBA@1m (typical) Up to 98 dBA possible if required
    Details
  • Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • The multi-sensor combines heat (H), carbon monoxide (CO), optical forward scatter (OFS) and optical backward scatter (OBS) The patented dual angle optical scatter technology allows identification of the particle source filtering potential false alarms due to steam and dust The gas sensing element (CO) within the chamber monitors the concentration of carbon monoxide, a product of incomplete combustion in some fire types, and potentially life threatening. The CO sensor allows rapid fire detection, with smouldering fires, in areas where smoke detectors could register false alarms Combined CO gas sensing with dual angle optical and heat allows a higher level of false alarm immunity whilst still improving the detection speed of certain types of fire Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • Attention tones can be programmed either as a bell (on speech variants) or a choice of 12 standard tones Soft’ start option Uniform sound distribution Low current consumption Fully synchronised sound patterns via the panel Selectable speech messages available to suit most requirements – switched on/off by the Vigilon panel Rich harmonic sound output using patented technique Options for sound output Standard mode = 90 dBA@1m (typical) Up to 98 dBA possible if required
    Details
  • Black Dual optical and heat sensor LPCB Approved Programmable sensor 'states' for different time frames Built in short circuit isolator Fully programmable speech facility Up to 20 seconds of messages can be stored Adjustable sound level Monitored line input/output Base supplied separately
    Details