/Addressable Detection
  • Brand Information; Responds to smouldering and flaming fires Less susceptible to false alarms caused by steam and dust Five response modes Remote test feature
    Details
  • Brand Information; Ideal in environments that are dirty or smoky under normal conditions Well suited for warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Five response modes Remote test feature
    Details
  • Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Resilient to dust Five response modes Remote test feature
    Details
  • Key Features:; Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Ideal in environments that are dirty or smoky Unaffected by wind or atmospheric pressure Remote test feature
    Details
  • Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature Rejection of transient signals
    Details
  • Ideal for a wide range of applications High immunity to false alarms Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Responds well to slow-burning, smouldering fires Suitable for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Mode 1 – has very high smoke sensitivity combined with high heat sensitivity. This gives a high overall sensitivity to both smouldering and flaming fires. Mode 2 – has a smoke sensitivity similar to that of a normal optical smoke detector. This mode is therefore equivalent to a standard optical detector. It is suitable for applications in which wide temperature changes occur under normal conditions. Mode 3 – has moderate smoke sensitivity combined with a moderate sensitivity to heat. This combination is considered the optimum for most general applications since it offers good response to both flaming and smouldering fires. Mode 4 – has lower than normal smoke sensitivity combined with high heat sensitivity. This makes it suitable for applications in which a certain amount of fumes or smoke is considered normal. Mode 5 – has no smoke sensitivity at all but gives a pure heat detector response meeting the response time requirements for a Class A1R detector in the European Standard EN 54- 5. In this mode the detector will respond to slowly changing temperatures and has a ‘fixed temperature’ alarm threshold at 58OC. The analogue value in this mode will give the approximate air temperature over the range 15OC to 55ºC. In Mode 5 the smoke sensor is still active though it does not contribute to the analogue signal. As a consequence, if the detector is used in a dirty or smoky environment the optical sensor drift flag may be activated in the heat only mode.; Ideal for a wide range of applications Enhanced false alarm management Recommended, in specific modes, for hotel bedrooms and hospital wards Unaffected by wind or atmospheric pressure Well-suited to sensitive environments Five EN 54 approved response modes Heat only and optical only options Remote test feature
    Details
  • Responds well to slowburning, smouldering fires Well-suited to bedrooms and escape routes Unaffected by wind or atmospheric pressure Five response modes Remote test feature
    Details
  • Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Responds to stationary flames with no flicker Sensitive to UV and low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised
    Details
  • Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Discovery or XP95 bases Loop-powered
    Details
  • Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye Compatible with Discovery and XP95 protocols Remote optical self-test function 90° field of view Up to 40m coverage
    Details
  • Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols
    Details
  • Loop-powered Sensitive to flickering IR radiation Detects through films of oil, dust, water and ice Responds to flickering flames, including those invisible to the naked eye False alarms due to lighting or flickering sunlight are minimised Compatible with Discovery and XP95 protocols
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine mounting bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine base Loop-powered
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion. Compact flame detector which fits into Discovery Marine bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Operation with control equipment using XP95 or Discovery protocol Quick and easy stainless steel 2 axis adjustable mounting bracket Ability to detect 0.1m2 flames at a distance of 25m as required by EN54 10
    Details