/Addressable Detection
  • Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S)
    Details
  • Continuous detection despite extremely large monitoring area Easy and rapid installation of the maintenance-free sensor cable Very high resistance to extremely contrary ambient influences(immune against heat, cold, humidity, corrosion, strong winds and draft) Undiminished precision under electromagnetic interference Unprecedented security against false alarms Very high sensor cable service life of up to 30 years Temperature profile over the complete measurement range delivers exact information of location, size and spreading of the fire Very low maintenance costs as the maintenance and the trouble shouting can be done from the control unit VdS certified to EN 54/5-A1 One controller unit will drive up two 8km spurs or one 8km loop Easy integration into existing installations Each sensor cable divided into up to 256 zones Individual configuration of 5 alarm criteria per zone Good network connection through Modbus, TCP/IP, FTP and SCPI interfaces
    Details
  • ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
    Details
  • Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
    Details
  • Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Triple IR solar blind sensing technology Multiple Field Interfaces Detection range: Up to 65m for 0.1m2 n-heptane pan fire Automatic optical path monitoring, Integral flame simulation and remote walk test help reduce the on-going life time cost of the flame detector installation Video verification via the integrated optional flameproof camera
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Key Features:; Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine mounting bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Operation with control equipment using XP95 or Discovery protocol Quick and easy stainless steel 2 axis adjustable mounting bracket Ability to detect 0.1m2 flames at a distance of 25m as required by EN54 10
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion. Compact flame detector which fits into Discovery Marine bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin fire LED's allow 360° viewing Pulsing/non-pulsing controlled from panel*1 Electronically Addressed Approved by LPCB, LR & GL
    Details
  • Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine base Loop-powered
    Details
  • Removable, High Performance chamber Twin fire LED's allow 360° viewing Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel*1 Approved by LPCB, LR & GL Available in ivory, white or black
    Details
  • Ideal for a wide range of applications High immunity to false alarms Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature Rejection of transient signals
    Details
  • Responds well to slow-burning, smouldering fires Suitable for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54
    Details
  • Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Advanced multi-sensor designs Built-in line isolator (851PH Only) Quick and easy to install Extended drift compensation Two way infra-red communication to the 850EMT Engineering Management Tool Fire, isolate and fault LED indications Any Pantone colour available with CPD approval Comprehensive range of bases and base accessories
    Details
  • Approved to MED by GL Removable, High Performance chamber Twin LEDs allow 360° viewing – green when polling, red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & VdS
    Details
  • Key Features:; Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces Reduces cabling, no interface required No additional power source required Easy installation uses a common plug in base for smoke and heat detectors Can be used on all vessels as fully marine approved
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL Available in ivory
    Details
  • Removable, High Performance chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB EN54: Part 7, LR & GL SIL Level 2 approved variant available
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available Available in ivory
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC
    Details
  • Key Features:; User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree ° viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • Key Features:; Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Ideal in environments that are dirty or smoky Unaffected by wind or atmospheric pressure Remote test feature
    Details