Optical Detector Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs
-
Key Features:; Dual Optical Technology reduces false alarms Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs
-
54°C Heat Detector Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs
-
Optical Smoke and 54°C (A1R) Heat Sensors in-one housing Evolution FSK protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs
-
Optical Detector with built in Sounder Sounder ~ 85dB(A) @ ~ 3.1mA Drive Output for dedicated EV-PSBCN Evolution FSK protocol EEPROM Addressed (Programmer)
-
Latest Generation Nittan Optical Chamber Omniview 360° LED Robust fully modulated AS Communications Protocol EEPROM addressed (Address stored in on-board EEPROM, programmed by handheld programmer) WILL REPLACE ST-P-AS
-
Thermistor Heat Sensor Robust Fully Modulated AS Communications Protocol DIL Switch Addressed
-
Thermistor Heat Sensor Omniview 360° Direct replacement for ST-H-AS Robust Fully Modulated AS Communications Protocol EEPROM addressed (Address stored in on-board EEPROM, programmed by handheld programmer)
-
Key Features:; Removable, High Performance chamber Twin LEDs allow 360 viewing – green when polling, turn red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & VdS SIL Level 2 approved variants available Available in white; Enhanced Performance Chamber New Outer Cover Design Software Advances Increase Noise Immunity Fully backwards compatible
-
-
Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Protec Algo-Tec 6000PLUS Protocol Ideal for detecting shouldering fires Devices display address numbers Easy to address FAST addressing Reduce false alarms
-
Universal Mode - EN54 pt.7 - CEA4021 - IS07240.7 Resilient Mode - EN54 pt.7 - CEA4021- IS07240.7 High Performance Optical - EN54 pt.7 - IS07240.7 Compensated CO Fire Sensing - LPS1265 - IS07240.6 Heat Detection - EN54 pt.5 A1R - IS07240.5 CO Toxic Gas Detection- EN50291
-
-
-
-
Senses products of combustion from fast burning fires Complies to EN 54 Pt7 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Alarm verification, self test, auto contamination adjustment
-
Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Automatic self test EN54 Part 5 approved
-
Responds to slow burning fires Complies to EN 54 Pt7 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor Alarm verification, self test, auto contamination adjustment
-
Senses both smoke and heat Heat only facility Smoke element complies with EN54 Part 7 and CEA4021 Heat element complies with EN54 Part 5 Class A1 and A2 Analogue sensing - reduces false and unwanted alarms Addressable - system knows the status and location of every sensor
-
Multi-criteria fire sensing Enhanced detection certainty False alarm discrimination Fuzzy logic algorithms Selectable algorithms Microprocessor based Smoke element complies with EN54 Pt7 Heat element complies with EN54 Pt5 certification A1
-
-
-