Key Features; Dual LEDs for 360º visibility Advanced detection and communication protocols Easy installation and maintenance Sleek low-profile housing Durable sensor head, no need for replacement SMD circuit board design. High quality and reliability guaranteed
-
-
-
Low profile - only 2” high Simple and reliable device addressing Supports 16 operational modes Automatic compensation for sensor contamination Built-in fire test feature Uses the noise-immune Digital Communication Protocol (DCP), which utilizes interrupts for fast response to fires Two built-in power/alarm LEDs Programmable non-polling LEDs Non-directional smoke chamber Vandal resistant security locking feature 10 years CO sensor life span*
-
-
-
User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin fire LEDs allow 360-degree viewing Pulsing/non-pulsing controlled from panel Electronically addressed LPCB & VdS approved to Classes A, B & C
-
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
-
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
-
-
Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
-
-
-
-
Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
-
Key Features:; Tri colour LED offering red, green and amber colour Rotary decade address switches 0 - 159 Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility New base design to complement the detector
-
Optical Detector with built in Sounder Sounder ~ 88dB(A) @ ~ 3.5mA Drive Output for dedicated EV-PSBCN Evolution FSK protocol EEPROM Addressed (Programmer)
-
Key Features:; Dual Optical Technology Plus Heat Sensor Reduces False Alarms Evolution FSK Protocol EEPROM Addressed (Programmer) RIL and Base Control Outputs
-
-
Key Features:; Compatible with the Notifier Range of Analogue Addressable Fire Alarm Control Panels. Including the Notifier ID3000, Notifier ID2000, Notifier ID50 and Notifier ID60 Panels. Part of the New Notifier Opal Range of Analogue Addressable Detectors. Colour : Ivory (To Match Colour of Previous Notifier Detectors and Bases) New Replacement for the Notifier SDX-751EM Detector Backwards Compatible with Existing Notifier Systems LPCB Approved Tri Colour LEDs
-
-
How the SMART4 works; Unique, true four sensor Multi-criteria detector Fully integrated Infra-Red sensor to support the fire alarm decision CO gas sensing for fastest response to slow developing and smouldering fires Highest possible immunity to unwanted alarms Automatic drift compensation of smoke sensor and CO cell Twin LED indicators providing 360° visibility Wide temperature range Built in test switch Stable communication with high noise immunity
-
Extremely high sensitivity, high power output IR LED and high gain IR receiver amplifier based smoke sensor Improved signal stability using the latest LED technology for professional applications Redesigned smoke chamber to further reduce the risk of false alarms 3-colour LED’s to locate alarms and speed up diagnostics and fault finding Integrated and controlled isolators Support for the latest OPAL protocol which offers superior performance and diagnostics capabilities Full backward compatibility with existing systems Rotary decade address switches
-
Advanced laser light source and patented optical design. Notifier Analogue Addressable communications protocol provides extremely reliable operation proven in millions of worldwide detector installations. Sensitivity: 9 levels from 0.07% to 6.56% obs/m. Rotary DECADE address switches. Dual bi-colour (red/green) LEDs flash green when Normal and are steady red in Alarm. Dual LED design provides 360° viewing angle. Built-in magnetic test switch, or automatic test commanded from panel.
-
Dual Technology Sensor Combined Smoke and Heat Sensors Ideal Multi-application Sensor Independent Channel Control Day/Night Operation Protec Algo-Tec™ 6000 Protocol Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms
-
Key Features:; Protec Algo-Tec™ 6000 Protocol Ideal where Smoke Detection is Unsuitable Fast Response Thermistor Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms
-
Key Features:; Ideal where Smoke Detection is Unsuitable Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing
-
Ideal Where Smoke Detection is Unsuitable Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Electronic Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing Reducing False Alarm VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Sensor VAD; -; Dual Technology Sensor Combined Smoke and Heat Sensor Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Integral Short Circuit Isolator Devices Display Address Number VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Attention tones can be programmed to match system sounders Volume control for individual devices including ’Soft’ start option Uniform sound distribution at all angles Low current consumption with capacity for up to 125 units per loop Fully synchronised sound patterns via the control panel Voiced Enhanced option with selectable speech messages available to suit most requirements Rich harmonic sound output using patented technique Unique monitoring of sounder element to ensure operation in an emergency Output typically 90dB(A) @1m Self-monitoring to prevent overload of loop in event of cable fault; S-Quad Benefits:; Comprehensive range of analogue addressable fire sensors all within ONE device Supported and powered on the Vigilon Loop – only one set of terminations and one cable required for multisensor, sounder, speech and visual alarm functionality Increased loop alarm load capable of powering 200 sensor-sounders or 100 sensor-sounder VADs Built-in short circuit isolators in every device Monitored input facility – fire, fault, non-fire – reduces the installed cost of the system and reduces the need for separate interfaces Monitored repeat LED output Loop powered installation incorporating S-Quad requires no additional interfaces or extra monitored sounder circuits S-Quad’s intelligent design ensures quick and simple installation with more wiring space within the base
-
IP Rating: IP30 Approximate Weight: 0.11 Kg Operating Temperature: -10°C to +50°C Compliant to EN54 Part 7