Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
-
-
Multiple fully approved sensitivity settings Utilises fully digital Hyfire protocol Dual alarm LEDs providing 360deg cone of visibility Dust Restrict Chamber (DRC) technology offering advanced immunity to airborne contaminants Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool 5-year product warranty
-
Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Highly reliable digital protocol Built in bi directional loop isolation in all devices Extended temperature range (-30°c to +70°c) Magnet test facility Compliant with EN54 - 5 & 7:2001 (ppropriate to device type) Improved system capacity of up to 240 deivces per loop Full integration with the Hyfire wireless system and devices Bi colour 360°LED provide device status information from any view Temperature sensor switchable between class AIR and class B
-
Multiple modes of operation Auto addressing capability on compatible fire control panels Bi-directional isolator to protect against cable faults Utilises fully digital Hyfire protocol with high noise rejection Dual bi-colour LEDs providing 360deg cone of visibility Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool Magnet test capability 5 year product warranty
-
Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Multiple fully approved sensitivity settings Auto addressing capability on compatible fire control panels Bi-directional isolator to protect against cable faults Utilises fully digital Hyfire protocol with high noise rejection Dual bi-colour LEDs providing 360deg cone of visibility Dust Restrict Chamber (DRC) technology offering advanced immunity to airborne contaminants Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool Self-test magnet option 5 year product warranty
-
Incorporates Optical & Heat elements Removable, High Performance Chamber Twin fire LED's allow 360° viewing Polling LED's controlled from Panel Variable sensitivity Electronically Addressed Approved to EN54 Part 5 & 7
-
User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin fire LED's allow 360° viewing Pulsing/non-pulsing controlled from panel Electronically Addressed IP Rated to IP67
-
Nine modes of operation Utilises fully digital Hyfire protocol with high noise rejection Dual alarm LEDs providing 360deg cone of visibility Dust Restrict Chamber (DRC) technology offering good immunity to airborne contaminants Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool 5 year product warranty
-
features; Low standby current Highly linear thermistor circuit Twin fire LED's allow 360° viewing Electronics free mounting base Variable sensitivity Electronically Addressed Approved to EN54 Part 5
-
Key Features; Nine modes of operation Utilises fully digital Hyfire protocol with high noise rejection Dual bi-colour LEDs providing 360deg cone of visibility Dust Restrict Chamber (DRC) technology offering good immunity to airborne contaminants Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool Magnet test capability 5 year product warranty
-
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Protec Algo-Tec 6000PLUS Protocol Unprecedented false alarm rejection
-
Removable, High Performance Chamber Twin fire LED's allow 360° viewing Electronics-free mounting base Variable sensitivity Electronically Addressed Approved to EN54 Part 7
-
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated electronic sounder Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Unprecedented false rejection
-
Multiple technology sensor Combined smoke, heat and CO sensors Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator
-
Key Features:; Multiple technology sensors Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Day / night operation Protec Algo-Tec 6000PLUS protocol Devices display address number FAST addressing Unprecedented false alarm rejection
-
User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing - green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB & VdS approved to Classes A1 & C SIL Level 2 approved variants available
-
Multiple technology sensor Combined smoke, heat and carbon monoxide sensors Ideal multi-application sensor Integrated high intensity LED beacon Loop powered / low current Integral short circuit isolator Devices display address number FAST addressing Unprecedented false alarm rejection
-
Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB & VdS approved to classes A1 & C SIL Level 2 approved variants available Available in white; Enhanced Performance Chamber New Outer Cover Design featuring indicative sensor type markings Software Advanced Increase Noise Immunity Fully backwards compatible
-
User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree viewing - green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB & VdS approved to Classes A, B & C SIL Level 2 approved variants available
-
Removable, High Performance chamber Twin LEDs allow 360 viewing - green when polling, turn red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & Vds SIL Level 2 approved varients available
-
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number
-
Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated voice enhanced sounder Integrated high intensity LED beacon Seven selectable voice messages Loop powered / low current Programmable volume control Integral short circuit isolator
-
Dual technology sensor Combined smoke and heat sensor Ideal multi-application sensor Integrated electronic sounder Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number FAST addressing and reduced false alarms
-
Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Dual technology sensor Combines smoke and heat sensor Ideal multi-application sensor Integrated electronic sensor Integrated high intensity LED beacon Loop powered / low current Programmable volume control Integral short circuit isolator Devices display address number
-
Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
-
Key Features:; Dual technology sensor Combined smoke and heat sensors Ideal for multi-purposes Independent channel controls Day / night operation Protec Algo-Tec 6000PLUS Protocol Devices display address number Fast addressing Reduce false alarms