Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54
-
The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC
-
Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S)
-
ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
Solar Blind for false alarm free operation Intrinsically safe or standard versions Fast response to flame Detect a 0.1m2 fire at a range of 20m Automatic health check feature Discrete ultra low profile design Fits a standard MX detector base or functional base Integral alarm LED with 360 degree angle of view Use T110 infrared test source (With separate adaptor) Complies to EN54-10 for Flame Detectors
-
Heat only detector (A1R or A2S) (no sensitivity selection) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low) Compensated Carbon Monoxide detector (sensitivity: High, Normal or Low)combined with heat (A1R) Carbon Monoxide Detector (sensitivity: High, Normal or Low); ATEX/IECEX certified intrinsically safe Ex II1GD Higher reliability through the use of galvanic barriers Lower cost system design and installation as one type of detector can be used throughout,coupled with a full range of devices Enhanced safety in Accommodation areas Provides the designer with greater flexibility in protecting hazardous areas Suitable for use in Zone 0, Zone 1, Zone 2, Zone 20, Zone 21 and Zone 22 Complies to EN54-7 for Smoke Detectors, EN54-5 for Heat Detectors, EN54-11 for Call Points and EN54-18 for I/O Devices
-
-
-
-
-
-