/Addressable Detection
  • Fast short circuit isolator in every device 15 combinations of smoke & heat detection modes Multi stage alarms - pre alarm feature 7 sound patterns - plus off, 3 different volume settings - if using Sita Multipoint with integral sounder Auxiliary digital inputs and outputs are available at any Addressable Multipoint device Automatic continuous self calibration Addressable Multipoint detector is monitored for all failures of sensor chamber - warning is indicated when a smoke detector head requires servicing Maintenance is made easy with the unique disposable optical chamber, designed as a cost effective solution to cleaning and re-calibration
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Multiple fire detection modes FireClass digital detection algorithms CO fire detection technology Up to 250 detectors per loop (dependant on panel choice) Optional bi-directional line isolation Remote detector verification & temperature read out Highly featured service tool Programmable alarm LED with 360o viewing angle Fire, isolated and fault LED indication Optional detector locking pin Variety of sounder bases Protected optical chamber screen Robust coated electronics Extended Service Life EN54 and CPD approved
    Details
  • Attention tones can be programmed either as a bell (on speech variants) or a choice of 12 standard tones Soft’ start option Uniform sound distribution Low current consumption Fully synchronised sound patterns via the panel Selectable speech messages available to suit most requirements – switched on/off by the Vigilon panel Rich harmonic sound output using patented technique Options for sound output: Standard mode = 90 dBA@1m (typical) Up to 98 dBA possible if required
    Details
  • Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • The multi-sensor combines heat (H), carbon monoxide (CO), optical forward scatter (OFS) and optical backward scatter (OBS) The patented dual angle optical scatter technology allows identification of the particle source filtering potential false alarms due to steam and dust The gas sensing element (CO) within the chamber monitors the concentration of carbon monoxide, a product of incomplete combustion in some fire types, and potentially life threatening. The CO sensor allows rapid fire detection, with smouldering fires, in areas where smoke detectors could register false alarms Combined CO gas sensing with dual angle optical and heat allows a higher level of false alarm immunity whilst still improving the detection speed of certain types of fire Each sensor element has sensitivity settings which can be adjusted to suit the environment / application and can be programmed for different time periods during the day or night Repeat fire LED output as standard (if monitored input not used) Operational LED blink ‘On/Off’ option Monitored Input - which can be Fire, Fault or Supervisory
    Details
  • Black Dual optical and heat sensor LPCB Approved Programmable sensor 'states' for different time frames Built in short circuit isolator Fully programmable speech facility Up to 20 seconds of messages can be stored Adjustable sound level Monitored line input/output Base supplied separately
    Details
  • Attention tones can be programmed either as a bell (on speech variants) or a choice of 12 standard tones Soft’ start option Uniform sound distribution Low current consumption Fully synchronised sound patterns via the panel Selectable speech messages available to suit most requirements – switched on/off by the Vigilon panel Rich harmonic sound output using patented technique Options for sound output Standard mode = 90 dBA@1m (typical) Up to 98 dBA possible if required
    Details