  • Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Multiple fully approved sensitivity settings Utilises fully digital Hyfire protocol Dual alarm LEDs providing 360deg cone of visibility Dust Restrict Chamber (DRC) technology offering advanced immunity to airborne contaminants Open style mounting base offers easy wiring and low pressure locking Programmable using the Device Programming Tool 5-year product warranty
    Details
  • Key Features:; Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Highly reliable digital protocol Built in bi directional loop isolation in all devices Extended temperature range (-30°c to +70°c) Magnet test facility Compliant with EN54 - 5 & 7:2001 (ppropriate to device type) Improved system capacity of up to 240 deivces per loop Full integration with the Hyfire wireless system and devices Bi colour 360°LED provide device status information from any view Temperature sensor switchable between class AIR and class B
    Details
  • Built in short circuit isolation New advanced Opal protocol allows mapping of the loop for precise fault location using isolators Tri colour LED offering red, green and amber colours Rotary decade address switches Pure white colour to complement modern buildings 100% mechanical and electrical backwards compatibility Base designed to ease installation and wiring
    Details
  • Key Features:; Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Ideal in environments that are dirty or smoky Unaffected by wind or atmospheric pressure Remote test feature
    Details
  • The mode of detector may be:; Optical smoke only detector (sensitivity High, Normal or Low) HPO smoke detector (sensitivity High, Normal or Low) Heat only rate-of-rise (A1R) detector (no sensitivity selection) Heat only fixed temperature 60oC (A2S) (no sensitivity selection) Optical (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) HPO (sensitivity High, Normal or Low) combined with heat fixed temperature 60oC (A2S) These detectors are designed to comply with EN/IEC 60079-0:2006, EN/IEC 60079-11:2007 and EN/IEC 61241-11:2006 for intrinsically safe apparatus; ATEX Code: Ex II 1GD Cenelec Code: Ex ia IIC T5/Ex iaD 20 T100oC
    Details
  • Key Features:; User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree ° viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate of Rise Heat elements Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Electronically addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available Available in ivory
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL SIL Level 2 approved variants available
    Details
  • Key Features:; User selectable modes Incorporates Optical & Heat elements Removable, High Performance Chamber Twin LEDs allow 360 degree viewing – green when polling, turn red in fire Pulsing/non-pulsing controlled from panel Variable sensitivity Electronically Addressed LPCB EN54: Part 7, LR & GL Available in ivory
    Details
  • Removable, High Performance chamber Twin LEDs allow 360 degree viewing green when polling, turning red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB EN54: Part 7, LR & GL SIL Level 2 approved variant available
    Details
  • Approved to MED by GL Removable, High Performance chamber Twin LEDs allow 360° viewing – green when polling, red in fire Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel Approved by LPCB & VdS
    Details
  • Key Features:; Unlike UV and UV/IR detection, not blinded by oil mist in machinery spaces Reduces cabling, no interface required No additional power source required Easy installation uses a common plug in base for smoke and heat detectors Can be used on all vessels as fully marine approved
    Details
  • Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Advanced multi-sensor designs Built-in line isolator (851PH Only) Quick and easy to install Extended drift compensation Two way infra-red communication to the 850EMT Engineering Management Tool Fire, isolate and fault LED indications Any Pantone colour available with CPD approval Comprehensive range of bases and base accessories
    Details
  • Intelligent Universal Smoke Detector Low profile, discreet and unobtrusive Superior performance and reliability Attractive new design Smart Card Addressing Technology Designed for fast easy installation Optional Locking Kit May be used in systems that meet BS5839 Pt1 Integral and remote alarm LED Wiring polarity independent LPCB approved to EN54
    Details
  • Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security Responds well to fast-burning, flaming fires Designed to operate in a variety of environments Remote test feature Rejection of transient signals
    Details
  • Responds well to slow-burning, smouldering fires Suitable for bedrooms and escape routes Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Ideal for a wide range of applications High immunity to false alarms Unaffected by wind or atmospheric pressure Remote test feature Rejection of transient signals
    Details
  • Removable, High Performance chamber Twin fire LED's allow 360° viewing Locking mechanism (sensor to base) Variable sensitivity Electronically addressed Pulsing/non-pulsing controlled from panel*1 Approved by LPCB, LR & GL Available in ivory, white or black
    Details
  • User selectable modes Incorporates Fixed Temperature and Rate Of Rise Heat elements Twin fire LED's allow 360° viewing Pulsing/non-pulsing controlled from panel*1 Electronically Addressed Approved by LPCB, LR & GL
    Details
  • Responds to stationary flames with no flicker Sensitive to UV radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine base Loop-powered
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion. Compact flame detector which fits into Discovery Marine bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Responds to stationary flames with no flicker Sensitive to low-frequency flickering IR radiation emitted by flames during combustion Compact flame detector which fits into Discovery Marine mounting bases Loop-powered False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques
    Details
  • Operation with control equipment using XP95 or Discovery protocol Quick and easy stainless steel 2 axis adjustable mounting bracket Ability to detect 0.1m2 flames at a distance of 25m as required by EN54 10
    Details
  • Key Features:; Over 20 fire detection modes Tyco MX FASTLOGIC Expert algorithms MX HPO detection Algorithms Up to 250 detectors per loop Remote detector verification & temperature read out Programmable alarm LED with 360o viewing angle Optional detector locking pin Variety of sounder and relay detector bases Address flag stays with the base Approved by all major classification societies for use on vessels Lower cost system design and installation as one detection type can be used throughout the vessel Lower cost of ownership as no radioactive source disposal costs together with less spares holding Enhanced safety in accommodation areas by using the unique Carbon Monoxide (CO) detectors Major Cable saving options using loop powered ancillaries Allows easier decision making by operator because of remote temperature and smoke density read-out
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details
  • Advanced array based detector Powerful signal processing on DSP with algorithms to give reliable flame detection Detection range: Over 50m for 0.1m2 n-heptane pan fire Field of view: 90° horizontal, 85° vertical with full range maintained High immunity to false alarms Solar blind Masking of areas in field of view Automatic optical path monitoring Advanced self-test and service features Built-in video camera (option): View protected area with alarm location and status overlay IEC 61508 Approved (SIL2)
    Details