Dual Technology Sensor Combined Smoke and Heat Sensors Ideal Multi-application Sensor Independent Channel Control Day/Night Operation Protec Algo-Tec™ 6000 Protocol Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms
-
Key Features:; Protec Algo-Tec™ 6000 Protocol Ideal where Smoke Detection is Unsuitable Fast Response Thermistor Devices Display Address Number Easy To Address FAST™ Addressing Reduced False Alarms
-
Key Features:; Ideal where Smoke Detection is Unsuitable Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing
-
Ideal Where Smoke Detection is Unsuitable Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Electronic Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Programmable Volume Control Integral Short Circuit Isolator Protec Algo-Tec™ 6000PLUS Protocol Devices Display Address Number FAST™ Addressing Reducing False Alarm VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Sensor VAD; -; Dual Technology Sensor Combined Smoke and Heat Sensor Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered Low Current Integral Short Circuit Isolator Devices Display Address Number VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Dual Technology Sensor Combined Smoke and Heat Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Ideal Multi-Application Sensor Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensors Integrated Electronic Sounder Integrated EN54-23 Visual Alarm Device Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Multiple Technology Sensor Combined Smoke, Heat and Carbon Monoxide Sensor Integrated Voice Enhanced Sounder Integrated EN54-23 Visual Alarm Device Seven Selectable Voice Messages Loop Powered & Low Current Programmable Volume Control Integral Short Circuit Isolator Unprecedented False Alarm Rejection VAD Classification Adjustable from 3m to 7.5m Room Coverage Volume
-
Attention tones can be programmed to match system sounders Volume control for individual devices including ’Soft’ start option Uniform sound distribution at all angles Low current consumption with capacity for up to 125 units per loop Fully synchronised sound patterns via the control panel Voiced Enhanced option with selectable speech messages available to suit most requirements Rich harmonic sound output using patented technique Unique monitoring of sounder element to ensure operation in an emergency Output typically 90dB(A) @1m Self-monitoring to prevent overload of loop in event of cable fault; S-Quad Benefits:; Comprehensive range of analogue addressable fire sensors all within ONE device Supported and powered on the Vigilon Loop – only one set of terminations and one cable required for multisensor, sounder, speech and visual alarm functionality Increased loop alarm load capable of powering 200 sensor-sounders or 100 sensor-sounder VADs Built-in short circuit isolators in every device Monitored input facility – fire, fault, non-fire – reduces the installed cost of the system and reduces the need for separate interfaces Monitored repeat LED output Loop powered installation incorporating S-Quad requires no additional interfaces or extra monitored sounder circuits S-Quad’s intelligent design ensures quick and simple installation with more wiring space within the base
-
IP Rating: IP30 Approximate Weight: 0.11 Kg Operating Temperature: -10°C to +50°C Compliant to EN54 Part 7