-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Key Features:; 12 zonal fire and fault indications Activate controls via keyswitch or code entry 1.25 Amp switch mode power supply Nom 27V DC Class change I/P Alert I/P 6 programmable switched -ve outputs Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays
-
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
-
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
-
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
-
"Sturdy 1.5mm mild steel enclosure with textured, off white, paint finish (RAL 7035 as standard) Top knockouts for 20mm cable glands, rear oval cable knockouts and one knockout provided at bottom of panel Quality fibreglass circuit boards, surface mount components Display mounted controls access keyswitch Generous internal clearances for cabling and glanding 2,4,8 & 16 Zone models house up to 12Ah SLA battery set. 32 zone houses up to 18Ah set Motherboard & power supply/transformer mounted on easily removable chassis for ease of installation Text inserts used for zone descriptions Insertable text option for controls & panel indications allowing easier multilingual support"
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
"Precept DC EN 16 Zone Repeater Panel with no Power Supply - 2605116 The 2605116 is a 16 Zone Precept Repeater Panel. The Precept Repeater Panel range can be 8, 16 or 32 Zone. The Precept AC range comes with a power supply whereas the Precept DC range doesn’t come with a power supply. The Precept Repeater Panel can range from 8, 16 or 32 Zone. As this Repeater Panel doesn't come with a power supply, it is powered from the Main Control Panel."
-
"Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface"
-
"Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs"
-
"Fike Ocelus Conventional 8 Zone Fire Panel “ 500-0008; Access via password “ removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies"
-
"Fike Ocelus Conventional 4 Zone Fire Panel “ 500-0004; Access via password “ removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Eight detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry Manufactured by C-TEC in the UK Two detector zone circuits Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU Wide range of test and fault-finding facilities Four open-collector outputs (Fire, Fault, Remote and Reset) 'Class change' and alert inputs Installer-friendly design Attractive flush or surface mountable plastic lid and enclosure - no bezel required Low 25mA quiescent current Multiple indicators No system expansion connections Fully compatible with C-TEC's ActiV range of conventional fire detectors"
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"
-
"Two-wire and standard versions in two, four or eight zones Compatible for use on BS5839: Part 1: 2017 installations Two-wire repeaters and ancillary boards Simple, single board construction Compatible with wide range of detection devices Two monitored sounder outputs Three Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
"2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)"
-
"2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)"
-
"Key Features:; 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)"
-
"Key Features:; 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)"
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
"Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
-
"Ampac ZoneFinder 2 Zone Conventional Control Panel - 2183-0201 The ZoneFinder range of conventional fire detection and alarm panels is a highly cost effective option for small building premises requiring coverage for up to twelve detection zones. Certified to EN54 parts 2 & 4, the ZoneFinder panels incorporate an integral power supply with space for standby batteries. Two versions are available, the ZoneFinder offering 2 or 4 detection zones and the ZoneFinder PLUS, offering 2 through to 12 detection zones. Both versions offer individual zone selection for conventional or Twin Wire operation along with one-man walk test mode facility and false alarm management options. Activation of controls is available via key switch or pass-code entry. In addition, the ZoneFinder Plus can be fitted with High Spec Expansion cards to provide additional sounder, relay and switched –ve outputs. A fully functional repeater panel is available which communicates using a 2 core data cable with the main ZoneFinder PLUS panel via a plug in comms card. The comms card also incorporates 6 programmable switched –ve outputs. Key Features: 2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode"
-
UL864 approved Two, four or eight initiating circuits Initiating circuits individually configurable as Fire, Water flow or Supervisory Two 2A notification appliance circuits Selectable NAC sync protocols Two 2.0A notification appliance circuits 6.5A power supply Alarm verification selectable by zone Resettable Aux power output rated at 0.3A Aux power configurable to power off on Fire condition Fire, Trouble and Supervisory relays Single person walk test function Optional DACT Many advanced configuration options 72 hour standby with 7Ah batteries Compact enclosure Fire Drill capability
-
Key Features:; From 2 to 32 zones (up to 32 detectors per zone). EN54-2 / CPD approval (BSI). Comprehensive end-user facilities (access level 2). Designed & built using the latest technology for optimum performance and consistently high quality. Extensive configurable facilities for the engineer via DIP switches. 4 alarm circuits as standard (4 zone panel and above). Up to 5 fully-functional repeaters - 2-wire RS485. Range of EN54 compliant power supply modules, designed to meet the specific load requirements of each size panel. Zonal one-man test feature and sounder one-man test facility. Short circuit to fire setting for use with older type detectors. Panel inputs for class change, evacuate, silence alarms, system reset. 3 open-collector outputs for evacuate, buzzer active, disablement active. Auxiliary supply output - monitored fuse. Optional timer clock/counter module. Optional foreign languages text insertable versions available. Optional semi-flush and fully flush mounting bezels available.
-
Competitive system Choice of 2 or 4 zone panels Simple "one-shot" auto-reset user test facility Complies with EN54 Programmable fire/fault output relay Zone/sounder circuit disabling for easy maintenance Supplied complete with battery and end of line devices