1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode Disablement of detector circuits Disablement of alarm circuits; Fire Detection Zones Fully Compliant with EN54 Parts 2 & 4 Manual Device Activation Indication Coincidence Detection Non-latching Zones Zone Disablements Alarm Disablements User Walk Test
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement User Walk Test
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode (only one zone at once in user mode) Disablement of detector circuits Disablement of alarm circuits Disablement of any programmed delays Disablement of the optional fire link interface
-
-
Key Features:; Modern, elegant design Easy removable parts for quick and clean installation Default regional setup modes Normal, head-out & intrinsically safe zone support Supervised alarm notification outputs EN54 compliant potential free fire & fault relays Class change, day/night & remote reset facilities Auxiliary 24VDC supply output with reset support Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test Auxiliary standard & supervised relay output boards Networkable up to 64 zones
-
Key Features:; Modern, elegant design Easy removable parts for quick and clean installation Default regional setup modes Normal, head-out & intrinsically safe zone support Supervised alarm notification outputs EN54 compliant potential free fire & fault relays Class change, day/night & remote reset facilities Auxiliary 24VDC supply output with reset support Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test Auxiliary standard & supervised relay output boards Networkable up to 64 zones
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
4 to 12 Zones Twin Wire selection by DIL switch Fully approved to EN54-2 & 4 Three year warranty as standard Integral 3 Amp switch mode PSU Class Change & Alert programmable inputs Programmable relays and outputs Test Mode (with or without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available 2 Additional sounder circuits with high spec expansion card Fully functional repeater panels Can support up to 8 repeater panels Key-switch or code entry for activation of controls Space for up to 7.0Ah batteries Two monitored sounder circuits fitted as standard Integral detector removal monitoring
-
Key Features:; Modern, elegant design Easy removable parts for quick and clean installation Default regional setup modes Normal, head-out & intrinsically safe zone support Supervised alarm notification outputs EN54 compliant potential free fire & fault relays Class change, day/night & remote reset facilities Auxiliary 24VDC supply output with reset support Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test Auxiliary standard & supervised relay output boards Networkable up to 64 zones
-
Zones switchable between standard conventional and intrinsically safe zones (using isolator barrier) One man test facility Class change input Interlink relay functionality for connecting 2 panels together Supports an expansion card for Fire Routing Equipment, Fire Protection Equipment and fire relays per zone. Modern and discreet enclosure Batteries not supplied; Flexibility to configure zones to work in ATEX areas using an isolator barrier Simple system testing by a single fire alarm technician Capability to sound class change bell in schools Interlink relay allows for greater system flexibility Comprehensive protection for safety of building occupants Panel not out of place in public areas
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
-
Key Features:; Up to 8 repeaters per CFP master Includes its own Mains power supply that requires its own standby battery supply Provides the user with access to all AL1 and AL2 functions Master/Repeater communication achieved using CFP761 network driver cards (one CFP761 is supplied with the Repeater, an additional CF761 card is required at the master CFP) Communicates over screened two-wire fire resistant cable Total repeater network cable length should not exceed 1KM Attractive flush or surface mountable plastic lid and enclosure - no bezel required
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
4 to 12 Zones Twin Wire selection by DIL switch Fully approved to EN54-2 & 4 Three year warranty as standard Integral 3 Amp switch mode PSU Class Change & Alert programmable inputs Programmable relays and outputs Test Mode (with or without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available 2 Additional sounder circuits with high spec expansion card Fully functional repeater panels Can support up to 8 repeater panels Key-switch or code entry for activation of controls Space for up to 7.0Ah batteries Two monitored sounder circuits fitted as standard Integral detector removal monitoring
-
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives