Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
-
2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
-
4 x 40 character backlit LCD display Simple, colour coded buttons for controls Programmable display text Remote key switch input Full system control Test mode & disablement functions Fully functional or passive Up to 8 units supported on a system PC programming software
-
Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
-
16, 24 or 32 Zones 3 Modes to manage false alarms One man walk test Key-switch or code entry for access Three year warranty as standard Space for two 18AHr batteries Integral 5 Amp switch mode PSU Programmable relays & outputs Approved to EN54-2 & 4 Network up to 8 control panels Four monitored sounder circuits Class change & alert, programmable inputs Fire alarm routing output Test mode with or without sounders Integral detector removal monitoring Spacious enclosure for easy installation and cabling Three year warranty as standard
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
12, zonal, fire & fault indications 3 year warranty as standard Simple, colour coded buttons for controls Integral 1 amp switch mode PSU Class change & alert inputs Programmable outputs Test mode & disablement functions Fully functional or passive Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
-
16, 24 or 32 Zones 3 Modes to manage false alarms One man walk test Key-switch or code entry for access Three year warranty as standard Space for two 18AHr batteries Integral 5 Amp switch mode PSU Programmable relays & outputs Approved to EN54-2 & 4 Network up to 8 control panels Four monitored sounder circuits Class change & alert, programmable inputs Fire alarm routing output Test mode with or without sounders Integral detector removal monitoring Spacious enclosure for easy installation and cabling Three year warranty as standard
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
16, 24 or 32 Zones 3 Modes to manage false alarms One man walk test Key-switch or code entry for access Three year warranty as standard Space for two 18AHr batteries Integral 5 Amp switch mode PSU Programmable relays & outputs Approved to EN54-2 & 4 Network up to 8 control panels Four monitored sounder circuits Class change & alert, programmable inputs Fire alarm routing output Test mode with or without sounders Integral detector removal monitoring Spacious enclosure for easy installation and cabling Three year warranty as standard
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
4 to 12 Zones Twin Wire selection by DIL switch Fully approved to EN54-2 & 4 Three year warranty as standard Integral 3 Amp switch mode PSU Class Change & Alert programmable inputs Programmable relays and outputs Test Mode (with or without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available 2 Additional sounder circuits with high spec expansion card Fully functional repeater panels Can support up to 8 repeater panels Key-switch or code entry for activation of controls Space for up to 7.0Ah batteries Two monitored sounder circuits fitted as standard Integral detector removal monitoring
-
12 Zonal, Fire & Fault indications 3 Year warranty as standard Simple colour coded buttons for control Integral 1 Amp switch mode PSU Class change and Alert inputs Programmable Outputs Test Mode & Disablement functions Fully functional or passive Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
Haes 8 Zone Excel-EN Conventional / Twin Wire Control Panel with Standard Zone Card XLEN-8L; 2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode
-
4 to 12 Zones Twin Wire selection by DIL switch Fully approved to EN54-2 & 4 Three year warranty as standard Integral 3 Amp switch mode PSU Class Change & Alert programmable inputs Programmable relays and outputs Test Mode (with or without sounders) Alarm load of 2.4A shared across all sounder outputs Modular expansion zone cards available 2 Additional sounder circuits with high spec expansion card Fully functional repeater panels Can support up to 8 repeater panels Key-switch or code entry for activation of controls Space for up to 7.0Ah batteries Two monitored sounder circuits fitted as standard Integral detector removal monitoring
-
Sigma CP-R Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs Ancillary PCB Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire, coincidence and common fault contact outputs
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode