Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
2, 4 and 8 Zone non-expandable control panels Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Programmable non-latching Zones Delay timer programmable on/off per Zone Coincidence programmable for adjacent Zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset 2 Relay outputs fire and fault Fully EN54 part 2 and 4 compliant Repeater output Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL) Multiplexed output for sounders per zone (GFE-MPX-SNDR) Addressable Loop Interface card (GFE-ADLI)
-
2, 4 and 8 Zone non-expandable control panels Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Programmable non-latching Zones Delay timer programmable on/off per Zone Coincidence programmable for adjacent Zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset 2 Relay outputs fire and fault Fully EN54 part 2 and 4 compliant Repeater output Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL) Multiplexed output for sounders per zone (GFE-MPX-SNDR) Addressable Loop Interface card (GFE-ADLI)
-
2, 4 and 8 Zone non-expandable control panels Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Programmable non-latching Zones Delay timer programmable on/off per Zone Coincidence programmable for adjacent Zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset 2 Relay outputs fire and fault Fully EN54 part 2 and 4 compliant Repeater output Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL) Multiplexed output for sounders per zone (GFE-MPX-SNDR) Addressable Loop Interface card (GFE-ADLI)
-
RS232 RS485 Fibre Optics TCP/IP (specific for ORION Conventional Systems)
-
Key Features:; Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Delay timer programmable ON/OFF and Day/Night mode One man test 1 Supervised/ monitored sounder circuit Fully EN54 -2 and EN54-4 compliant
-
Key Features:; Up to 32 conventional smoke and/or heat detectors per Zone Active End of Line monitoring Delay timer programmable ON/OFF and Day/Night mode One man test 1 Supervised/ monitored sounder circuit Fully EN54 -2 and EN54-4 compliant
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
12, zonal, fire & fault indications 3 year warranty as standard Simple, colour coded buttons for controls Integral 1 amp switch mode PSU Class change & alert inputs Programmable outputs Test mode & disablement functions Fully functional or passive Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
Haes 8 Zone Excel-EN Conventional / Twin Wire Control Panel with Standard Zone Card XLEN-8L; 2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
-
2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 2 or 4 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 1.25 Amp switch mode power supply Nom 27V DC 2 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert I/P Fire & fault switched -ve outputs False alarm mode Muster alarm feature Test mode, with or without sounders Disable zones, sounder O/Ps & aux O/Ps Alarm load, 800mA shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Essento Marine Overview:; 8 - 12 zones Activate controls via keyswitch or code entry Compatible with Apollo Orbis Marine detectors Integral detector removal monitoring Earth fault monitoring 3 Amp switch mode power supply Nom 27V DC 4 monitored sounder outputs 2 Aux C/O relays (1 x Fire) (1 x Fault). voltage free Class change I/P Alert (pulsing) I/P Fire & fault switched -ve outputs Program delays to ouputs False alarm modes A, B & C Muster alarm Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays Alarm load, 2.4A shared between all sounder outputs All sounder circuits are fused @ 500mA with resettable fuses.
-
Key Features:; 12 zonal fire and fault indications Activate controls via keyswitch or code entry 1.25 Amp switch mode power supply Nom 27V DC Class change I/P Alert I/P 6 programmable switched -ve outputs Test mode, with or without sounders Disable zones, sounder O/Ps, aux O/Ps & delays
-
4 x 40 character backlit LCD display Simple, colour coded buttons for controls Programmable display text Remote key switch input Full system control Test mode & disablement functions Fully functional or passive Up to 8 units supported on a system PC programming software
-
1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
-
1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
-
Competitive system Choice of 2 or 4 zone panels Simple "one-shot" auto-reset user test facility Complies with EN54 Programmable fire/fault output relay Zone/sounder circuit disabling for easy maintenance Supplied complete with battery and end of line devices
-
Facility for signalling to repeater panel provided as standard on 8 zone panel Charger with built in temperature compensation Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode