Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface
-
"Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface"
-
UL864 approved Two, four or eight initiating circuits Initiating circuits individually configurable as Fire, Water flow or Supervisory Two 2A notification appliance circuits Selectable NAC sync protocols Two 2.0A notification appliance circuits 6.5A power supply Alarm verification selectable by zone Resettable Aux power output rated at 0.3A Aux power configurable to power off on Fire condition Fire, Trouble and Supervisory relays Single person walk test function Optional DACT Many advanced configuration options 72 hour standby with 7Ah batteries Compact enclosure Fire Drill capability
-
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output
-
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output
-
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
"Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output; Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
"Two-wire and standard versions in two, four or eight zones Compatible for use on BS5839: Part 1: 2017 installations Two-wire repeaters and ancillary boards Simple, single board construction Compatible with wide range of detection devices Two monitored sounder outputs Three Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay detectors only Zonal sounder delay call points only Coincidence input selection I.S Barrier selection by zone Short circuit fire by zone Non latching zones Silent zones Zone input delay General panel configuration"
-
2 wire systems, reduces installation cabling 2-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non latching selection by zone Silent zones (common sounder outputs) Zone input delay for sprinkler system connection AlarmSense® local alarm feature supported Simple, single board construction Installer friendly Compatible with all AlarmSense® devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Allows systems to be installed in accordance with BS5839: Part 6
-
"Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs"
-
Sigma CP-R Two wire serial connection Up to 7 panels per system 230V AC or 24V DC powered versions Full control over main panel Volt free fire and fault contact outputs Ancillary PCB Two wire serial connection Up to 7 boards per system 230V AC or 24V DC powered versions Open collector zonal fault outputs Volt free fire, coincidence and common fault contact outputs
-
Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls Same look and feel as Sigma range Sigma Matrix can easily be upgraded on site with minimal cost and effort
-
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
-
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
-
-
Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
"Precept DC EN 16 Zone Repeater Panel with no Power Supply - 2605116 The 2605116 is a 16 Zone Precept Repeater Panel. The Precept Repeater Panel range can be 8, 16 or 32 Zone. The Precept AC range comes with a power supply whereas the Precept DC range doesn’t come with a power supply. The Precept Repeater Panel can range from 8, 16 or 32 Zone. As this Repeater Panel doesn't come with a power supply, it is powered from the Main Control Panel."
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode Disablement of detector circuits Disablement of alarm circuits; Fire Detection Zones Fully Compliant with EN54 Parts 2 & 4 Manual Device Activation Indication Coincidence Detection Non-latching Zones Zone Disablements Alarm Disablements User Walk Test
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode (only one zone at once in user mode) Disablement of detector circuits Disablement of alarm circuits Disablement of any programmed delays Disablement of the optional fire link interface
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement User Walk Test
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement
-
Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"
-
"Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013"