Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output
-
Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode Disablement of detector circuits Disablement of alarm circuits; Fire Detection Zones Fully Compliant with EN54 Parts 2 & 4 Manual Device Activation Indication Coincidence Detection Non-latching Zones Zone Disablements Alarm Disablements User Walk Test
-
The following functions can be performed by the user when entering the user access code:; Silencing an alarm condition Sounding the alarms Resetting the panel after an alarm activation Testing the front panel indications and buzzer Programming a zone into test mode (only one zone at once in user mode) Disablement of detector circuits Disablement of alarm circuits Disablement of any programmed delays Disablement of the optional fire link interface
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement User Walk Test
-
Fully Compliant with EN54 Parts 2 & 4 Manual or Automatic Device Indication Zone Delays Coincidence Detection Fire Link Delay Non-latching Zones Zone Disablements Alarm Disablements Fire Link Disablement
-
Available in 2, 4 and 8 zone models Attractive surface or recessed mounting Comprehensive range of engineering functions Zone disablements Ability to differentiate between Manual Call Point and automatic detector alarm Programmable sounders for automatic and/or manual activation 72 Hour stand-by as standard Third party approved to latest EN54 Parts 2 and 4. Meets the requirements of BS5839 Part 1: 2013
-
-
Key Features:; Modern, elegant design Easy removable parts for quick and clean installation Default regional setup modes Normal, head-out & intrinsically safe zone support Supervised alarm notification outputs EN54 compliant potential free fire & fault relays Class change, day/night & remote reset facilities Auxiliary 24VDC supply output with reset support Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test Auxiliary standard & supervised relay output boards Networkable up to 64 zones
-
Key Features:; Modern, elegant design Easy removable parts for quick and clean installation Default regional setup modes Normal, head-out & intrinsically safe zone support Supervised alarm notification outputs EN54 compliant potential free fire & fault relays Class change, day/night & remote reset facilities Auxiliary 24VDC supply output with reset support Default support for special functions such as: - EN54 compliant user access levels - mixed zones - full front panel diagnostics - one-man walk test Auxiliary standard & supervised relay output boards Networkable up to 64 zones