/Conventional Panel
  • Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
    Details
  • 16, 24 or 32 Zones 3 Modes to manage false alarms One man walk test Key-switch or code entry for access Three year warranty as standard Space for two 18AHr batteries Integral 5 Amp switch mode PSU Programmable relays & outputs Approved to EN54-2 & 4 Network up to 8 control panels Four monitored sounder circuits Class change & alert, programmable inputs Fire alarm routing output Test mode with or without sounders Integral detector removal monitoring Spacious enclosure for easy installation and cabling Three year warranty as standard
    Details
  • Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
    Details
  • 2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
    Details
  • 2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
    Details
  • From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
    Details
  • Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
    Details
  • From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
    Details
  • 1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
    Details
  • Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
    Details
  • From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
    Details
  • Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.
    Details
  • Up to 320 LED’s can be controlled Full colour printing Available in a range of standard enclosures to suit any application Bespoke sized units can be made upon request Choice of Red, Green or Yellow LED’s Available with or without controls Same look and feel as Sigma range Sigma Matrix can easily be upgraded on site with minimal cost and effort
    Details
  • From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
    Details
  • Competitive system Choice of 2 or 4 zone panels Simple "one-shot" auto-reset user test facility Complies with EN54 Programmable fire/fault output relay Zone/sounder circuit disabling for easy maintenance Supplied complete with battery and end of line devices
    Details
  • UL864 approved Two, four or eight initiating circuits Initiating circuits individually configurable as Fire, Water flow or Supervisory Two 2A notification appliance circuits Selectable NAC sync protocols Two 2.0A notification appliance circuits 6.5A power supply Alarm verification selectable by zone Resettable Aux power output rated at 0.3A Aux power configurable to power off on Fire condition Fire, Trouble and Supervisory relays Single person walk test function Optional DACT Many advanced configuration options 72 hour standby with 7Ah batteries Compact enclosure Fire Drill capability
    Details
  • Key Features:; From 2 to 32 zones (up to 32 detectors per zone). EN54-2 / CPD approval (BSI). Comprehensive end-user facilities (access level 2). Designed & built using the latest technology for optimum performance and consistently high quality. Extensive configurable facilities for the engineer via DIP switches. 4 alarm circuits as standard (4 zone panel and above). Up to 5 fully-functional repeaters - 2-wire RS485. Range of EN54 compliant power supply modules, designed to meet the specific load requirements of each size panel. Zonal one-man test feature and sounder one-man test facility. Short circuit to fire setting for use with older type detectors. Panel inputs for class change, evacuate, silence alarms, system reset. 3 open-collector outputs for evacuate, buzzer active, disablement active. Auxiliary supply output - monitored fuse. Optional timer clock/counter module. Optional foreign languages text insertable versions available. Optional semi-flush and fully flush mounting bezels available.
    Details
  • "Ampac ZoneFinder 2 Zone Conventional Control Panel - 2183-0201 The ZoneFinder range of conventional fire detection and alarm panels is a highly cost effective option for small building premises requiring coverage for up to twelve detection zones. Certified to EN54 parts 2 & 4, the ZoneFinder panels incorporate an integral power supply with space for standby batteries. Two versions are available, the ZoneFinder offering 2 or 4 detection zones and the ZoneFinder PLUS, offering 2 through to 12 detection zones. Both versions offer individual zone selection for conventional or Twin Wire operation along with one-man walk test mode facility and false alarm management options. Activation of controls is available via key switch or pass-code entry. In addition, the ZoneFinder Plus can be fitted with High Spec Expansion cards to provide additional sounder, relay and switched –ve outputs. A fully functional repeater panel is available which communicates using a 2 core data cable with the main ZoneFinder PLUS panel via a plug in comms card. The comms card also incorporates 6 programmable switched –ve outputs. Key Features: 2 to 12 Zone versions available Fully Approved by LPCB to EN54-2 & 4 Twin-Wire option selected via integral switches False alarm management Integral detector removal monitoring Integral Switch Mode PSU and battery space 2 Monitored sounder circuits 2 Auxiliary VFCO (1x Fire) (1x Fault) Class Change and Alert input Test Mode including One Man Walk Test Control Enable via key switch or passcode"
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI. Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry. Manufactured by C-TEC in the UK. Two detector zone circuits. Four conventional sounder circuits Integral 1.5A EN54-4/A2 compliant switch mode PSU. Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones. Two on-board relays (Fire and Fault). Two open-collector outputs (Remote and Reset). 'Class change' and alert inputs. Installer-friendly design. Attractive flush or surface mountable plastic lid and enclosure - no bezel required. Low 25mA quiescent current. Multiple indicators. System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards. Space for two x 12V 3.3Ah VRLA batteries. Fully compatible with C-TEC's ActiV range of conventional fire detectors."
    Details
  • "Key Features:; 2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)"
    Details