-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Advanced Features Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
Product Benefits; CPD approved to EN54-2&4 Simple to install Robust fire resistant ABS moulded enclosure Battery space for up to 72 hour stand-by 2, 4 or 8 zone versions available; Zones configurable for delay, coincidence, short-circuit alarm, capacitor or resistive end of line. Fire and fault outputs - volt-free relay or monitored Auxiliary power output for ancillary equipment 2 configurable inputs for ancillary equipment (e.g. class change, alert, etc.) Space for two option modules Optional 8-way relay module, common or zonal switching Optional 1.5A 4-way sounder module, common or zonal switching
-
Sigma K11 range in which detectors and call points are wired on separate circuits to sounders (two sounder circuits are provided). Sigma T11 range in which detectors call points and sounders are wired to the same pair of cables. Commonly referred to as a two-wire system.; Fully certified to BS EN54-2 and BS EN54-4 2-wire and standard versions in 2, 4 or 8 zones Compatible for use on BS5839: Part 1: 2002 installations 2-wire repeaters and ancillary boards Fully programmable using simple menu options:; Simple, single board construction Installer friendly Compatible with wide range of detection devices Two monitored sounder outputs 3 Amp power supply Auxiliary power output
-
Facility for signalling to repeater panel provided as standard on 8 zone panel Charger with built in temperature compensation Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode
-
1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP