-
Clear back-lit 40 character 8 line LCD display Programming options via the front panel or laptop computer Remote system interrogation and diagnostics Extensive Alarm Management resources Self-Auto Learn capabilities Day Night sensitivity settings Versatile multi-processor architecture Event log and printer options Flexible modular expansion and panel Add Ons Optional 32, 64, 96 & 128 zone indicators SmartTerminal repeater options Complies to EN54-2 and 4
-
4 x 40 character backlit LCD display Simple, colour coded buttons for controls Programmable display text Remote key switch input Full system control Test mode & disablement functions Fully functional or passive Up to 8 units supported on a system PC programming software
-
2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
-
2 or 4 zone False alarm management mode Twin Wire selection by DIL switch Approved to EN54-2 & 4 Smart design, easy to install, commission & service Class change inputs & pulsing inputs Fire & fault relays 2 monitored sounder circuits One man walk test Key-switch or code entry for activation of controls Non latching zone for interfacing Fault diagnostics mode
-
Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
-
Complies with BS5839: Part 4: 1988 Can be used on pre BS5839 type systems 12 - 48 zones as standard more available on request Class change input Common fire and fault contacts Line continuity upon detector removal Remote signal contact and isolate Shop interface input Zonal one man test Zonal selection for operation with intrinsically safe barriers Zonal volt free contacts Zone isolate facility Compatible with most popular detectors Option for plug-in two stage sounder cards Flush or Surface
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
-
1, 2, 4 or 8 zones panels Flexible, high specification system Simple “one-shot” auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Custom configured versions available to meet specific project requirements Third party approved
-
From 2 to 32 zones (up to 32 detectors per zone) EN54-2 approval by LPCB Comprehensive end user facilities (access level 2) Designed and built using the latest technology for optimum performance and consistently high quality Extensive configuarable facilities for the engineer via DIL switches 4 alarm circuits as standard (4 zone panel and above) Up to 5 fully functional repeaters - 2 wire RS485 Zonal one man test feature and sounder one man test facility Short circuit to fire setting for use with older type detectors Panel inputs for class change, evacuate, silence alarms, system reset 3 open collector outputs for evacuate, buzzer active, disablement active Auxiliary supply output - monitored fuse Panel expansions boards for open collector, relay and alarm outputs Optional timer clock/counter module
-
Built in detector removal indication facility From 1 to 8 zones 4 Alarm circuits on 4-8 zone panels Conforms to the requirements of EN54-2 User friendly access code one-man test facillity Non-latching zone feature Class change input Earth fault monitoring Fully functional repeater available (4 & 8 zone panels only) Removable cable entry grommets User friendly controls Surface or semi-flush mounting as standard Ample termination space Flame restant polycarbonate enclosure Log book and manual supplied Complies with SMC and LVD directives
-
Up to 5 repeater panels can be driven by the C1631 repeater panel driver which is required to be installed in the main control panel.