-
Low current consumption - only 11mA Quickly and easily installed Excellent sonorous tone up to 100dB(A) at 1m Slim profile Fully suppressed and polarised Simple installation with multi-fixing base plate 24V bells certified by LPCB to EN54-3:2001 24V bells compliant with Construction Products Directive
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) Suitable for use in Zone 0,1 & 2 Robust GRP Body Suitable for offshore and petrochem Certificated Intrinsically Safe; Certification: CENELEC EN50014, 20 & 39 BAS02ATEX1258X EExia IIB T4 Zones 0,1 & 2 Material: UV stable glass reinforced polyester body. Clear polycarbonate cover/lens. Retained stainless steel cover screws. Finish: Painted Red Tube Type: Xenon discharge Lens Colour: Clear Terminals: 8 x 2.5mm2 Flash Rate: 1 flash per second Cable Entries: Up to 3 x M20 via knockouts Tube Energy: 0.5 Joules Weight: 1.4kg Certified Temperature: -55°C to + 60°C Ingress Protection: IP66 & IP67 Tube Life: >1 x 106 Flashes Voltage: 24V via suitable barrier Current Consumption: 71mA max nominal
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 Robust Corrosion Resistant GRP body High Power (5 Joule) Certificated Flameproof; Voltage: 24Vdc Tube Energy: 5 Joules Peak Current Consumption (mA): 320 Effective Intensity (Cd): 29 Peak Intensity (Cd): 22213 Power Consumption (Watts): 8 Note: The Cd figures are for a clear lens @ 1Hz flash rate. For red lens multiple by 0.15 Weight: 2.5Kg Certified Temperature: EExd -55°C to + 70°C (T4) -55°C to + 55°C (T5) -55°C to + 40°C (T6) Ingress Protection: IP66 & IP67 Terminals: 6 x 2.5mm2 Entries: 2 x 20mm ISO EExd. Certification: BASEEFA EExd IIB 135°C (-55 to AMB +70°C)T4 100°C (-55 to AMB + 55°C)T5 85°C (-55 to AMB + 40°C)T6 Cert. No. 99 ATEX 2195X. CENELEC EN50014 and EN50018 Material Body: Glass reinforced polyester Lens: Glass Cover Screws + Backstrap: Stainless steel 316 Finish: Red
-
Features; Conventional I.S. system Suitable for worst case (EEx ia IIC T5) High Performance Optical (HPO) smoke detector Compatible with S231i+ flame detector Compatible I.S. callpoint Suitable for use in Zone 0,1,2,20,21& 22 For use in hazardous areas Robust GRP construction Powerful Output, up to 118dBA; Terminals: 6 x 2.5mm2 Mounting: Stainless steel bracket with ratchet facility Cable Entries: 2 x 20mm EExd. Tone Selection: 27 user selectable tones. Certification: CENELEC EN50014,18,19 BASEEFA Cert. No. BAS00ATEX2097X, EExd IIC. Zones 1 and 2. Material: Body & horn in anti-static, UV stable, glass reinforced polyester. Swivel bracket & captive cover screws in stainless steel. Nominal Output (dBA) Input Current (mA)* 93 50 105 100 108 150 111 200 112 250 114 300 115 350 118 380 Product Code 576.501.049 Flameproof Horn Sounder (DB3D048N2BNR) Output measured with 24VDC input voltage. Tone set to 970Hz continuous. Weight: 6.0kg approx Ingress Protection: IP66 / IP67 Voltage: 12VDC to 48VDC Certified Temperature: -20o C to +70o C
-
-
Operating Voltage 18 to 32Vdc Alarm State Current 1.2mA @ 68dBA (low vol) 6.8mA @ 90dBA (max vol) Operating Temp. -25°C to +70°C Relative Humidity 10% to 95% (non cond.) Dimensions 108 dia x 38 mm Weight 195g
-
Key Features:; Exceeds the illumination requirements of EN54-23 Patented electronic design maximises system efficiency by minimising power consumption Reduces the number of devices required most rooms can be protected with a single device Installation is quick and simple with mounting and wiring made only to the base the head clicks on to the base during commissioning Sonos Pulse VADs share the same base mounting and wiring as previous versions make the transition to Pulse versions as simple as possible Pulse Alert Technology enables the coverage pattern to be fixed at the optimum performance level Sonos Pulse VADs protect everyone including people prone to photosensitivity epilepsy Eliminates power surges during system start up Surpasses the ingress protection requirements of EN54-23 making them suitable for a wide variety of environmental conditions
-
Key Features:; Different Gong Sizes High Sound Output Low Current Consumption Simple Installation Multi-fixing Baseplate
-
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 7.5 metres (m) Room Coverage Volume 2.4 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23
-
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 7.5m Room Coverage Volume 2.4 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23
-
Key Features:; LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets Adjustable from 3 to 7.5m Room Coverage Volume Up to 3 metres (m) Mounting Height Adjustable Flash Rate Approved to EN54 Part 23
-
LED Technology for Long Service Life Cost Effective Installation Solution Ideal for Bedrooms, Bathrooms and Toilets 3 metres (m) Mounting Height 7.5m Room Coverage Volume Adjustable Flash Rate Approved to EN54 Part 23