/Edwards Fire Alarm
  • Product Description The Edwards EST SIGA-MCR Control Relay Module is an addressable Signature Series component. A Form C dry contact relay in the SIGA-MCR may control equipment shutdown or external appliances like door closers, fans, and dampers. Edwards EST's SIGA-MCR plugs into any available module space on a SIGA-UIO(R) series motherboard, and captive screws secure it to the board. All wiring connections are made to terminals on the motherboard.
    Details
  • Product Description The Edwards EST SIGA-MCRR Polarity Reversal Relay Module is an addressable Signature Series component used to power and activate the audible sounder in Signature Audible Detector Bases. UIO Mount.
    Details
  • Product Description The Edwards EST SIGA-MCC2 is a Dual Input (Riser) Signal Module compatible for use with XLS100 and XLS1000 Loop Controllers.
    Details
  • Product Description The Edwards EST SIGA-MCC1 is a Single Input Riser I/O Control Module intended for use with the Signature Loop Controller. See also SIGA-CC1 for equivalent product.
    Details
  • Product Description Edwards EST SIGA-MCC1S Synchronization Output Module
    Details
  • Product Description The Edwards EST SIGA-MAB is a Plug-in (UIO) Universal A/B Module. Plugs into UIO2R, UIO6R or UIO6 Motherboards. Uses Two Module Addresses. Module function is determined by the personality code selected by the installer. Features 14 programmable personality codes. For use exclusively with the Signature Loop Controller.
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. Replace with: SIGA-IPHS. The Edwards EST SIGA-IS is a plug-in Ionization Smoke Detector. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool
    Details
  • Product Description The Edwards EST model SIGA-LED Remote Alarm Indicator connects to the SIGA-SB or SIGA-SB4 Standard Base only. It features a North American single-gang plastic faceplate with a white finish and red alarm LED.
    Details
  • Product Description Edwards EST SIGA-IM Isolator Module (IM) is an addressable device that protects a signaling line circuit (SLC) from a to wire-to-wire short. The SIGA-IM module monitors line voltages and opens the data line when a short is detected, isolating the short between the two modules located electrically closest to the short. The loop controller assigns an address to the SIGA-IM module. The module uses one detector address on the SLC.
    Details
  • Product Description The Edwards EST SIGA-IO is an Input Output Module. The actual operation of the SIGA-IO and MIO is determined by the “personality code” selected by the installer, which is downloaded to the module from the loop controller during system configuration. Input/Output Modules are compatible with GE Security’s Signature Loop Controller operating under EST3 version 3.0 or higher, and QuickStart Signature Loop Intelligent Controller. Mounts to a standard North American one-gang electrical box, making it ideal for locations where only one module is required. Separate I/O and data loop connections are made to each module.
    Details
  • Product Description Edwards EST SIGA-IB4 4-inch Isolator Detector Base is intended for use with Signature Series Sensors. Features a built-in line fault isolator for use on Class A circuits. A detector must be installed for it to operate. The isolator base does not support the SIGA-LED Remote LED. Includes SIGA-TS4 Trim Skirt.
    Details
  • Product Description Edwards EST SIGA-HRD Fixed Temp / RoR Heat Detector is designed for use with the Signature Loop Controller. COMPATIBLE BASES and ACCESSORIES: — SIGA-SB Detector Mounting Base - Standard — SIGA-SB4 4-inch Detector Mounting Base w/ SIGA-TS4 Trim Skirt — SIGA-RB Detector Mounting Base w/Relay — SIGA-RB4 4-inch Detector Mounting Base w/Relay w/ SIGA-TS4 Trim Skirt — SIGA-IB Detector Mounting Base w/Fault Isolator — SIGA-IB4 4-inch Detector Mounting Base w/ Fault Isolator and SIGA-TS4 Trim Skirt — SIGA-LED Remote Alarm LED. (Connects to the SIGA-SB or SIGA-SB4 Standard Base only.) — SIGA-AB4G Audible (Sounder) Base for Fire Detectors — SIGA-AB4GT Audible (Sounder) Base for CO and Fire Detectors — SIGA-TCDR Temporal Pattern Generator — SIGA-CRR Polarity Reversal Relay can be used for sounding to other audible bases on the same 24 Vdc circuit. — SIGA-TS4 Trim Skirt (supplied with 4-inch bases) — SIGA-DMP Detector Mounting Plate — SIGA-RTA Detector Removal Tool — SIGA-VA Detector Cleaning Tool NOTE: Replaces SIGA-HFS & SIGA-HRS
    Details