/Edwards Fire Alarm
  • Product Description The EST BPS-10A Booster Power Supply (10 amp) is designed to extend the signaling capacity of a fire alarm, security, or access control system. The BPSs can be connected to existing Class A or Class B notification appliance circuits (NACs) or activated via option modules. The BPSs can either pass or generate synchronization signals for Genesis sync strobes. The BPSs have four independent NAC / AUX circuits that are supervised when configured for NAC, plus a trouble relay. The input circuits of the booster power supply can be connected to 12 VDC or 24 VDC systems.
    Details
  • Product Description The EST BPS-10A Booster Power Supply (10 amp) is designed to extend the signaling capacity of a fire alarm, security, or access control system. The BPSs can be connected to existing Class A or Class B notification appliance circuits (NACs) or activated via option modules. The BPSs can either pass or generate synchronization signals for Genesis sync strobes. The BPSs have four independent NAC / AUX circuits that are supervised when configured for NAC, plus a trouble relay. The input circuits of the booster power supply can be connected to 12 VDC or 24 VDC systems.
    Details
  • Product Description This is the Replacement Board for the Edwards EST BPS6A Booster Power Supply (6.5 amp) is designed to extend the signaling capacity of a fire alarm, security, or access control system. The BPSs can be connected to existing Class A or Class B notification appliance circuits (NACs) or activated via option modules. The BPSs can either pass or generate synchronization signals for Genesis sync strobes. The BPSs have four independent NAC/AUX circuits that are supervised when configured for NAC, plus a trouble relay. The input circuits of the booster power supply can be connected to 12 VDC or 24 VDC systems.
    Details
  • Product Description The Edwards EST C-DTS is a Detector Test Station, single-gang, flush mount.
    Details
  • Product Description The Edwards CF200-EWT is an Explosion-Proof Fixed Temperature Heat Detector. Model CF-200-EWT is rated for 200F (93C) Contacts: Single Pole Normally Open - Rated at: 3.0 amps at 6 to 125VAC; 1.0 amps at 6 to 28VDC; 0.3 amps at 125VDC; 0.1 amp at 250VDC.
    Details
  • Product Description The Edwards EST CRB4U-1 is a 4" relay detector base (1.25A @ 30 Vdc) for use with Edwards EST EC Series of Smoke and Heat Detectors.
    Details
  • Product Description Edwards CS2002-11 Manual Yellow Pull Station
    Details
  • Product Description NOTE: This part is discontinued by the manufacturer. There is no designated replacement. The Edwards DLD Dual Line Dialer provides two telephone line connections for transmitting system status changes to one or two compatible digital alarm communicator receivers (DACRs) over the public switched telephone network. For use with QS FACPs.
    Details
  • Product Description Edwards E-IDC1A Analog Class A Single Input Module is an analog addressable device used to connect a normally open, alarm, supervisory, or monitor type dry contact initiating device circuit (IDC) to a control panel. This module is designed for Class A circuit operation. The device address is set using the two rotary switches located on the front of the module. One device address is required. The device can be preset for alarm or supervisory operation using the slide switch located on the front of the module. The module can also be configured for other device types through front panel programming or the configuration utility.
    Details
  • Product Description The Edwards E-IDC1B Analog Single Input Mini Module connects a normally open, alarm, supervisory, or monitor type dry contact initiating device circuit (IDC) to the Edwards Signaling control panel. For Class B circuit operation.
    Details
  • Product Description The Edwards E-PD Intelligent Analog Optical Smoke Detector uses rotary switches to set address. COMPATIBLE BASES and ACCESSORIES: — B4U Standard Base — RB4U Relay Detector Base — IB4U Isolator Detector Base — SB4U Audible (Sounder) Detector Base — AB4G-SB Surface Box for Audible Base — RLED Remote alarm LED, use with standard base only — 211-10PKG Replacement optical chambers