//C-Tec CFP 4 Zone Conventional Fire Panel (LPCB Approved) – CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel (LPCB Approved) – CFP704-4

“Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.

Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

Manufactured by C-TEC in the UK.

Two detector zone circuits.

Four conventional sounder circuits

Integral 1.5A EN54-4/A2 compliant switch mode PSU.

Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

Two on-board relays (Fire and Fault).

Two open-collector outputs (Remote and Reset).

‘Class change’ and alert inputs.

Installer-friendly design.

Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

Low 25mA quiescent current.

Multiple indicators.

System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.

Space for two x 12V 3.3Ah VRLA batteries.

Fully compatible with C-TEC’s ActiV range of conventional fire detectors.”

SKU: Conventional Panel12 Category: Tag:

Description

“C-Tec CFP 4 Zone Conventional Fire Panel (LPCB Approved) – CFP704-4

LPCB certified to EN54-2/4, C-TEC’s CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, it includes two detector zones, four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/key switch entry.

A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters, relay expansion boards and EN54-13 system compliance devices are also available.

Key Features:

Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.

Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.

Manufactured by C-TEC in the UK.

Two detector zone circuits.

Four conventional sounder circuits

Integral 1.5A EN54-4/A2 compliant switch mode PSU.

Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.

Two on-board relays (Fire and Fault).

Two open-collector outputs (Remote and Reset).

‘Class change’ and alert inputs.

Installer-friendly design.

Attractive flush or surface mountable plastic lid and enclosure – no bezel required.

Low 25mA quiescent current.

Multiple indicators.

System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.

Space for two x 12V 3.3Ah VRLA batteries.

Fully compatible with C-TEC’s ActiV range of conventional fire detectors.”