Protec 6000PLUS/OPHTCO/SL Optical Smoke, Heat and Carbon Monoxide Multi-Sensor with Sounder and LED Beacon

The Protec 6000PLUS/OPHTCO/SL is an interactive addressable high performance optical smoke, heat and carbon monoxide multi-sensor. The detector’s multi-sensor technology will provide a formidable weapon in the pursuit of reliable fire detection and the avoidance of unwanted or false alarms. The sensor provides total confidence that when initiated, there really is a fire threat. The sensor incorporates infra-red light scattering for smoke detection, with thermal enhancement of the optical sensitivity, temperature detection equivalent to grade A2, and a third channel incorporating carbon monoxide (CO) sensing element.

The combination of optical smoke, heat and carbon monoxide gas sensing technology within one fire detector heat provides the ideal solution. The sensor can now detect free burning chemical fires, fires producing smoke and low levels of CO and heat, to deep seated smoldering fires, which produce little heat and smoke but large amounts of CO. Combining the results from all sensing channels, enables rapid fire detection with rejection of false alarms and increased sensor reliability.

The Protec Algo-Tec 6000PLUS/OPHTCO/SL sensor is equipped with an integrated loop powered electronic sounder with tree programmable sounder tone options: constant, pulse or warble selectable by the control panel along with adjustable volume control. A loop short circuit isolator is also incorporated within the head. The sensor sounder tones are compatible with the full range of Protec 6000 electronic sounders. Compliance with DDA legislation is assisted by the addition of Protec high intensity LED beacon to warn those with hearing impairments or in noisy environments. The beacon utilizes a high intensity LED with lower power consumption and increased reliability when compared to alternative indicators. The beacon is located in the center of the sensor so it can be viewed from all angles.

Key Features:

Multiple technology sensor

Combined smoke, heat and carbon monoxide sensors

Ideal multi-application sensor

Integrated electronic sounder

Integrated high intensity LED beacon

Loop powered / low current

Programmable volume control

Integral short circuit isolator

Unprecedented false rejection