  • Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB and GL SIL2 Approved variant available; Hochiki - IS Technology Guide Hochiki - Rate of Rise Detector - Specification Hochiki - Smoke Detector - Installation Guide Hochiki - Heat Detector - Datasheet Hochiki - IS Technology - Application Notes
    Details
  • Key Features:; Twin fire LEDs allow 360 degree viewing Electronics free mounting base Remote indicator output ATEX Classification to II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in ivory Approved by LPCB and GL SIL2 Approved variant available; Hochiki - Heat Detector - Datasheet Hochiki - Heat Detector - Installation Guide
    Details
  • Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist ATEX certified to EEx d IIC T6 (85 C) (zones 1, 21, 2 and 22) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Flame Detector - Datasheet Hochiki - Flame Detector - Leaflet Hochiki - Flame Detector - Installation Instructions
    Details
  • Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours dust and mist ATEX certification to: EEx ia IIC T4 (135 C) (zones 0, 1 and 2) Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - IS Detector - Brochure Hochiki - IS Detector - Installation Instructions Hochiki - IS Detector - Datasheet
    Details
  • Unaffected by convection currents, draughts or wind and solar-blind Tolerant of fumes, vapours, dust and mist Responsive to a flame more than 25 m away Selectable response speed Class 1 performance as defined in BS EN54-10:2002 (on the high sensitivity setting) Optical self-test SIL capable; Hochiki - Datasheet Hochiki - User Manual Hochiki - Certificate of Conformity
    Details
  • Removable, High Performance chamber Twin fire LEDs allow 360 degree viewing Supported by a range of barriers Remote indicator output ATEX Classification to: II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in white Approved by LPCB & VdS; Hochiki - Smoke Detector - Installation Instructions Hochiki - Smoke Detector - Datasheet Hochiki - Smoke Detector - Datasheet (2)
    Details
  • Removable, High Performance chamber Twin fire LEDs allow 360 degree viewing Supported by a range of barriers Remote indicator output ATEX Classification to: II 1G EEx ia IIC T5 Tamb=55C Suitable for installation in areas at Category 1 (inc all lower categories) Also available in ivory Approved by LPCB & VdS; Hochiki - Smoke Detector - Installation Instructions Hochiki - Smoke Detector - Datasheet
    Details
  • Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° field of view Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two M25 conduit entries Low power consumption; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1 sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two 25 mm conduit entries or two ¾” NPT Low power consumption High RFI and EMI immunity FM hazardous area approved Ex d ATEX approved CU-TR approved INMETRO approved Meets SIL 2 requirements Certified to EN54-10:2002 (option) FM 3260 performance; Refineries and oil production facilities Off-Shore platforms Turbine/Compressor enclosures Acetylene processing and storage Oil and Gas pipelines and pumping stations LNG/LPG loading and unloading facilities Natural Gas and CNG plants Ethanol, Methanol, and IPA production and storage Crude oil and gasoline storage and tank farms Aircraft hangars Hydrogen plants and storage Paint and solvent storage Chemical production, storage, and loading facilities Power plants Silane gas storage; Morley FS20X-211-24-6 - Data Sheet Morley FS20X-211-24-6 - Installation Manual
    Details
  • Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps; Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Multi spectrum design - for long distance detection and high false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities; Spectrex 40/40I - Data Sheet Spectrex 40/40I - User Guide Spectrex 40/40I - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L - Data Sheet Spectrex 40/40L - User Guide Spectrex 40/40L - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 150m sec Response to Saturated Signal Solar blind 4040LB with Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) - Models 40/40LB and 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Ex approved for Zone 1 hazardous area location: ATEX – IECEx – FM/FMC – CSA 3rd party Performance Tested: EN54-10 (LPCB) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40LB - Data Sheet Spectrex 40/40LB - User Guide Spectrex 40/40LB - Accessories
    Details
  • Multi spectrum design - for long distance detection of hydrocarbons and hydrogen flames High false alarm immunity Sensitivity selection - to ensure no zone crossover detection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance tested: EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Explosives & Munitions Waste Disposal facilities Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging areas Refinery Hydrogenation Space Industry hydroxyl propellant Static fuel Cell systems; Spectrex 40/40M - Data Sheet Spectrex 40/40M - User Guide Spectrex 40/40M - Accessories
    Details
  • Sensitivity selection Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested - EN54-10 (VdS) - FM3260; Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities; Spectrex 40/40R - Data Sheet Spectrex 40/40R - User Guide Spectrex 40/40R - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40U - Data Sheet Spectrex 40/40U - User Guide Spectrex 40/40U - Accessories
    Details
  • UV spectrum design Automatic and Manual Built-In-Test (BIT) - to assure continued reliable operation (in 40/40UB only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) model 40/40UB only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Tested: EN54-10 (VdS) - FM3260; Chemical plants Petrochemicals plants Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Aerospace Explosives & Munitions Waste Disposal facilities Paint and solvent processes; Spectrex 40/40UB - Data Sheet Spectrex 40/40UB - User Guide Spectrex 40/40UB - Accessories
    Details
  • Multi Spectrum Design - for long distance detection and high false alarm immunity High Speed Response – 50m sec Sensitivity Selection - to ensure no zone crossover detection Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Safety Integrity Level SIL2 (TUV) 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapors present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance: EN54-10 (VdS) - FM3260 (FM); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Explosives & Munitions Waste Disposal facilities; Spectrex 40/40UFI - Data Sheet Spectrex 40/40UFI - User Guide Spectrex 40/40UFI - Accessories
    Details
  • UV/IR Dual-Sensor High-Speed Response - 20m sec to flash fire Solar blind Automatic Built-In-Test (BIT) - to assure continued reliable operation Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - Analogue output for fast detection - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) 5-Year warranty User programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party performance: EN54-10 (VdS) - FM3260; Explosives & munitions Offshore Oil & Gas Onshore Oil & Gas Petrochemical plants Storage tank farms Aircraft hangars Chemical plants Power generation facilities Pharmaceutical industry Printing industry Warehouses Automotive industry Waste disposal facilities Aerospace industry Hydrogen Fuel Cell Industry Hydrogen Vehicle Parking & Refuelling Battery Charging Areas Refinery Hydrogenation Space Industry Hydroxyl Propellant Static Fuel Cell Systems; Spectrex 40/40UFL - Data Sheet Spectrex 40/40UFL - User Guide Spectrex 40/40UFL - Accessories
    Details
  • Key Features:; High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling; Flame Detector - User Manual Flame Detector - EXD Installation Guide Flame Detector - IS Install Guide Flame Detector - Maintenance Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002 IR2 Flame Detector Range; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling These sensors have been approved by Baseefa (notified body no: 1180) to EN60079-0, EN60079-11 and EN60079-26. The requirements of Directive 94/9/EC, the ATmosphere EXplosives ATEX Directive have also been met. Apparatus Certificate Number: BAS02ATEX1001 System Certificate Number: Baseefa08Y0078 Certified to: ATEX: II 1 G CENELEC/IEC: Ga Ex ia IIC T4; Zones 0, 1, 2; Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Brochure Flame Detector - Maintenance Guide Flame Detector - IS Install Guide Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Talentum - 16289 - Datasheet
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA,Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Intrinsically safe (IS) for hazardous areas. Die cast zinc alloy housing Ideal for use on machinery protection applications; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Fast response time for enclosed and dark areas High Sensitivity to Embers Selectable Output Options; Conventional 2 wire, 4-20mA, Relay Contacts (Fire/Fault, Pre-alarm - Latching or Non-latching) Selectable Response Speed Remote Control Self-Test Low Power Consumption Die cast zinc alloy housing Ideal for use on machinery protection applications Continues operation at temperatures up to 55°C; Agriculture Bed Fillings Chipboard/MDF Manufacture Dryers Dust Collection/Filters Textiles Paper Production Woodworking; Talentum Spark Detector - Data Sheet Spark detection - Where, when and why? Talentum - One detector for every application
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangars Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can you Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist High ambient temperature applications Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: II 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 Zones 1, 21, 2 and 22; Talentum IR3 Exd - Data Sheet Talentum Exd IR3 - Product Brochure Talentum IR3 Exd - Installation Guide Talentum IR3 Exd - User Manual Talentum IR3 Exd - Maintenance Guide Talentum IR3 Exd - One detector for every application Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Key Features:; Excellent immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10: 2002; Atria Coal Handling Pharmaceuticals Printing Spray Booths Nuclear Industry Waste Tips Storage Tanks Tunnels; Flame Detector - Maintenance Guide Flame Detector - Wiring Diagram Flame Detector - IS Install Guide Flame Detector - EXD Installation Guide Flame Detector - User Manual Flame Detector - Data Sheet Flame Detector - Brochure Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect
    Details
  • Excellent immunity to false sources Increased environmental protection Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Waste Recycling Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production Coal Handling; ATEX & IECEx certified: I I 2GD Ex d IIC T4 Gb Ex tb IIIC T135°C Db IP66 A21 [Zones 1, 21, 2 and 22] SIL 2 rated; Talentum IR3 - Data Sheet Talentum IR3 - Product Brochure Talentum IR3 - Installation Guide Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Excellent immunity to false sources Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Refineries Compressor Stations Fuel Loading Racks Chemical Plants Tunnels Waste Recycling Nuclear Power Sites Storage Tanks Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Aircraft Hangers Coal Handling Printing Petrochemical Offshore/Onshore LNG/LPG Production Biomass Storage and Handling; Talentum IR3 - Data Sheet Talentum IR3 - User Manual Talentum IR3 - Maintenance Guide Talentum IR3 - Wiring Diagram Talentum One Detector for Every Application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What types of flames can Talentum detect?
    Details
  • Key Features:; Highest immunity to false sources Suitable for indoor and outdoor areas Detects invisible flames from fuels such as hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002; Aircraft hangars Engine rooms Engine test facilities Generators High voltage equipment Nuclear industry Power plants Storage tanks; Flame Detector - Maintenance Guide Flame Detector - User Manual Flame Detector - Wiring Diagram Flame Detector - Installation Guide Flame Detector - Brochure Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose? What type of flames can your Talentum detect?
    Details
  • Highest immunity to false sources Solar blind Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel loading racks Storage tanks Aircraft hangers Petrochemical onshore/offshore Biomass storage and handling LNG/LPG production; ATEX: II 2GD Ex d IIC T6 [Zones 1, 21, 2 and 22] Worldwide approvals include EN54:10, with VdS and LPCB; Talentum UV / IR2 - User Manual Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - Maintenance Guide Talentum UV / IR - One detector for every application Distance Sensitivity of the Talentum Flame Detector What flame detector should I choose What types of flames can Talentum detect?
    Details
  • Highest immunity to false sources Solar blind High ambient temperature applications Tolerant of fumes, vapours, dust and mist Suitable for indoor and outdoor areas Unaffected by convection currents, draughts or wind Proven response to multiple fuel types Multi-spectrum detection Selectable output options Selectable response speed Selectable sensitivity levels Built in auto and manual test Low current consumption Fast response to fire; Chemical Plants Nuclear Power Sites Engine Rooms Spray Booths Pharmaceutical Production Military Applications Marine Industry Printing Refineries Fuel Loading Racks Storage Tanks Aircraft Hangers Petrochemical Onshore/Offshore Biomass Storage and Handling LNG/LPG Production; ATEX: II 2GD Ex d IIC T6 Zones 1, 21, 2 and 22; Talentum UV / IR2 - Data Sheet Talentum UV / IR2 - Product Brochure Talentum UV / IR2 - Maintenance Guide Talentum UV / IR2 - Installation Guide Talentum UV / IR2 - User Manual Distance Sensitivity of the Talentum Flame Detectors What flame detector should I choose? What type of flames can your Talentum detect?
    Details