/All Products
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4B - Data Sheet Spectrex 40/40L4B - User Guide Spectrex 40/40L4B - Accessories
    Details
  • High immunity to false sources For applications with visible light present Detects invisible flames from fuels such as Hydrogen and other inorganic fuels Selectable response speed Optical self-test Low power consumption Approved to EN54-10:2002 IR2 Flame Detector Range; Churches Coal Handling Fume Cupboards Printing Spray Booths Textiles Waste Handling; Flame Detector - Brochure Flame Detector - User Manual Flame Detector - EXD Installation Guide Flame Detector - Maintenance Guide Flame Detector - IS Install Guide Flame Detector - Data Sheet Distance Sensitivity of the Talentum Flame Detectors What types of flames can Talentum detect? What flame detector should I choose?
    Details
  • UV/IR Dual-Sensor Solar blind Automatic Built-In-Test (BIT) and Manual - to assure continued reliable operation (in 40/40L4B only) Heated window - for operation in harsh weather conditions (snow, ice, condensation) Multiple output options for maximum flexibility and compatibility: Relays (3) for Alarm, Fault and Auxiliary - 0-20mA (stepped) - HART Protocol for maintenance and asset management - RS-485, Modbus Compatible High Reliability - MTBF - minimum 150,000 hours Approved to Safety Integrity Level 2 (SIL2 – TUV) Model 40/40L4B only 5-Year Warranty User Programmable via HART or RS-485 Hazardous area zones: Zones 1 & 2 with IIC gas group vapours present - Zones 21 & 22 with IIIC dust type present Ex approved to: ATEX & IECEx - FM/FMC/CSA - TR CU (EAC) 3rd party Performance Approved - EN54-10 (VdS) - FM3260 Marine Approval - MED ‘Wheelmark’ approval (DNV); Offshore Oil & Gas installations Onshore Oil & Gas installations and pipelines Chemical plants Petrochemicals plants Storage Tank farms Aircraft hangars Power Generation facilities Pharmaceutical Industry Printing Industry Warehouses Automotive Industry Waste Disposal facilities Aerospace Industry Paint, Polymer and Glue processes; Spectrex 40/40L4 - Data Sheet Spectrex 40/40L4 - User Guide Spectrex 40/40L4 - Accessories
    Details
  • Installer and maintenance friendly; Triple IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) EN54-10 & CPD approved; Ziton - FF762 Datasheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Installer and maintenance friendly; Dual IR detector High specification units for critical applications IP65 Housing Low current consumption 2 Wire, 4 - 20 mA and relay operation Latching and non-latching operation High / Low sensitivity setting Tolerance to detector window contamination Remote self-test facility Microprocessor controlled Immunity to false sources (arc welding, lightning and static) Conforms to EN54: Part 10; Ziton - FF742 Datasheet
    Details
  • Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Key Features:; Fixed temperature alarm level ATEX compliance (6295 and 6296) Waterproof (IP67); Specialist Heat Detector - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details
  • Key Features:; Operating Voltage: 32VAC to 32Vdc Switching Current: 5 to 200mA Contact Resistance: <1 ohm Actuating Temp.:(preset) 60 to 240°C Fixed Temp. Only: Type E Accuracy: + or - 5% Ambient Temp.: -40 to +280°C Relative Humidity: 100% RH Thread Size M20x1.5mm Protection Category: IP67 CSIRO ActivFire Listed afp-1612 FPANZ Listed VF/214; T54B - Data Sheet
    Details