/Aspirating Smoke Detection (ASD) System
Aspirating Smoke Detection (ASD) System2020-04-08T08:29:32+01:00
Aspirating smoke detection System (ASD) are much more advantageous than passive smoke detectors as they are not reliant on room airflow.
This means that they are able to detect smoke before it is even visible which is crucial when it comes to alerting building occupants, saving lives and closely protecting valuable equipment and data storage.
By law, all workplaces must have some sort of smoke detection system in place. There are various detectors available to buy on the market and we have tested and hand-picked only the best to safeguard your premises.
  • 1 sampling pipe/1 detector EN 54-20 classes A, B, and C 5 alarm levels (3 pre-alarms and 2 alarms when using RIM36 Module) Response sensitivity settable from 0.002–10%/m Insensitive to dirt particles thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Perfected smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption ASD Config PC tool ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
    Details
  • 1 sampling pipe / 1 detector EN 54-20 classes A, B, and C 4 alarm levels (1 fire alarm, 3 fixed pre-alarms 30 / 50 / 70% when using RIM36 Module) Response sensitivity settable from 0.006–10%/m Insensitive to dirt particles due to particle suppression Low noise level, compliant with ISO 11690-1 Perfected smoke detection with HD sensor (high-dynamic technology) Low power consumption Onboard Configuration ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
    Details
  • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
    Details
  • Patented venturi pipe and duct housing One-pipe air sampling system Uniguard Superflow New cross-section (shape) of the venturi pipe gives an optimum of venturi effect Test hole on cover Simple installation Sensitive flow indicator Simple service and maintenance Installer-friendly connection of cables Foolproof installation of venturi pipe
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure