/Conventional Fire Alarm Ancillaries
Conventional Fire Alarm Ancillaries2020-04-05T06:31:45+01:00

Conventional Ancillaries Device From Reputable Brands

IWe have the very latest ancillary devices that are compatible with a huge range of Addressable Fire Alarm Systems products can all be found here at J K Fire.
  • Certified by UL to EN54-4:1997 +A1 +A2. Up to 1.2A current to load at 27.6V dc nominal regulated output. Charging capability to support 1.2 to 7Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection or circuit impedance (Ri) in excess of 500mW, caused by connector or wiring problem/corrosion, within 4 hours. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 2.0A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details
  • Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 2A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 17Ah 'E' Box Power Supply: 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 5A current to load at 27.6V dc nominal regulated output. Charging capability to support 7 or 17Ah batteries. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls below 21 V. Diagnostic indicator LED (Orange) (Internal). Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present Indicators check at start-up. Optional RS232 serial interface for fault reporting and diagnostics. Suitable to fit batteries up to 2 x 7Ah 'C' Box Power Supply - 275h x 330w x 80d (mm) Hinged Lid
    Details
  • Certified by VdS to EN54-4:1997 +A1: 2002 + A2: 2006 5A current to load at 27.6V dc nominal regulated output Electronic overload protection shuts down output until overload or short circuit is removed Battery Monitor detects battery missing, low battery, short-circuit or reverse connection Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14V No loss of output during automatic connection of battery to load on loss of mains Deep discharge protection disconnects battery from load when battery voltage falls to 21V Automatic start-up on battery only Fault indicator LED (Red) flashes on detection of output fault, battery fault, charger fault and mains failure Mains indicator LED (green) showing mains present Suitable to fit batteries up to 2 x 38Ah 'E' Box Power Supply - 420h x 400w x 80d (mm) Hinged Lid
    Details
  • Certified by UL to EN54-4:1997 +A1: 2002 + A2: 2006. Up to 10 A current to load at 27.6V dc nominal regulated output. Charging capability to support 18, 38 or 65Ah batteries with intelligent load enhancement. Electronic overload protection shuts down output until overload or short circuit is removed. Battery Monitor detects battery missing, low battery, short-circuit or reverse connection. Battery charging circuit is energised only when a battery is correctly connected and the battery voltage is greater than 14 V. No loss of output during automatic connection of battery to load on loss of mains. Deep discharge protection disconnects battery from load when battery voltage falls to 21 V. Fault indicator LED (Yellow) flashes on detection of output fault, battery fault, charger fault and mains failure. Mains indicator LED (Green) showing mains present. RS232 serial interface for fault reporting and diagnostics interface to OEM equipment. Suitable to fit batteries up to 2 x 38Ah 'H' Box Power Supply - 420h x 420w x 180d Hinged Lid
    Details
  • Fike Ocelus Conventional Standard Detector Base – 200-0014
    Details
  • Key Features:; Aesthetically discreet Superior performance and reliability Designed for rapid installation Remote LED connection
    Details
  • General Features:; 4 x 20mm gland entries. IP55 with supplied gasket.
    Details
  • Key Features:; Robust metal housing. Twin fused outputs. Temperature compensated charging. Deep discharge protection of batteries. Fault relay output. Size 383mm wide x 408mm high x 97mm deep. Weight 4.3 Kg (excluding batteries). Supply voltage 230VAC 50/60Hz. Comprehensive LED status indication.
    Details