/Addressable Audio Visual
  • Features; Manufactured to EN54 part 3 Integral sounder and detector base Volume and tone adjustable after installation Low Power Synchronisation Do not require use of a standard base (maybe installed directly onto a standard besa box)
    Details
  • MX LPAV3000 Loop Powered Sounder/Beacon - Addressable Base; High output programmable sounder base and sounder beacon base One point of installation for detector, isolator, sounder & beacon Loop powered from the MX Technology® Digital Loop High brightness Multi-LED Beacon Software programmable 15 Tones and 2 Flash Rates Integral line isolator RSM (Reflective Sound Monitoring) Can be used as a standalone device using the sounder blanking cap
    Details
  • Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time
    Details
  • Loop Powered - Reduced installation costs High Output / Low consumption - Lower lifetime costs Indoor and Outdoor models - Same sounder tones in all areas Sounder / LED Beacon Version - DDA Compliant 16 Tones and 2 Flash rates - Suites individual requirements Reflective Sound Monitoring RSM - Reassurance that ALL sounders are working Integral Line Isolator - Saves cost and installation time
    Details
  • A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic conventional bell tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Replace legacy LPSB3000 and LPAV3000
    Details
  • A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for pre alarm and class change Aesthetically pleasing rectangle wall mount option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • A compact and discrete solution VAD approved to EN54-23 with two ranges, standard power and high power available High power option provides a larger VAD coverage volume compared to standard Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Optimise the system design for lowest power requirements and lowest cost installation Triple light source One point of installation for detector, sounder and visual indicator with no additional wiring Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar. Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VADs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Provides an EN54-23 approved upgrade path for legacy systems
    Details
  • Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Reflective Light Monitoring (RLM) Automatic self-test Shorter light pulse for faster response Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box for use with suitable IP-rated glands and cabling Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • A compact and discrete solution One point of installation for detector, sounder and visual indicator with no additional wiring Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Independent addressable control of the sounder and beacon Built-in line isolator Select the tone, volume and flash rate using panel configuration software 15 selectable tones. Allows users to select the tone with which they are most familiar Realistic conventional bell tone 4 selectable volumes 2 selectable flash rates Different tones can be used for fire alarm and class change VIDs and sounders are synchronised over the entire loop A locking pin supplied with the base which prevents the unauthorized removal of the detector Replace legacy LPSB3000 and LPAV3000
    Details
  • Key Features:; A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes Select the tone volume using panel configuration software Different tones can be used for fire alarm and class change Rectangle wall mount for an aesthetically pleasing option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • A compact and unobtrusive sounder solution Reflective Sound Monitoring (RSM) Light is electronically monitored by the control panel Automatic self-test Indoor and outdoor versions Indoor models can be semi-flush or surface mounted including a choice of shallow or deep back box IP rated option has a deep surface back box Power and data from the loop. No additional wiring or power supplies required Built-in line isolator 16 selectable tones Realistic conventional bell tone 2 selectable volumes 2 selectable flash rates Select the tone volume and flash rate using panel configuration software Independent addressable control of the sounder and beacon Different tones can be used for pre alarm and class change Aesthetically pleasing rectangle wall mount option A locking pin/screw supplied which prevents unauthorized removal
    Details
  • Allows the 801/802/812/901 & 912 Sounder Base to become Addressable without the need to fit a Detector, thus creating an Addressable Loop Powered Sounder Suitable for wall or ceiling mounting Sounder Selection Tones as per 801/802/812/901 & 912 Sounder Base Fits the 801RB Relay Base to provide an Addressable Relay Base without the need to fit a Detector Colour matched to Sounder Bases Locked into Sounder Base using Detector Locking Pin SAM 800 is configurable in CONSYS SAB800 / SAB801 may be used with 5B or MUB bases SAB800 / SAB801 adds a Flashing Red Beacon facility to the 801/802/812/901 & 912 Sounder Base SAB801 Low current consumption (loop powered) SAB800 has two Modes of Operation - continuous or 2Hz flash, configurable in CONSYS SAB801 has two Modes of Operation - continuous or 1Hz flash , configurable in CONSYS
    Details
  • Key Features:; Very bright VID beacon Ideal for many general signalling applications Can be grid mounted for industrial applications Five different lens colours available
    Details
  • Enhanced sounder circuit integrity and reliability Compliant with EN 54 and BS 5839-1 Certified by LPCB to EN 54 Part 17 and 18 Potential cable savings 45 Sounders per loop System includes BansheeMT and FlashToneMT Can also be used with other sounder and strobe units Multiple interfaces can be installed dependent on size of system Isolator fits into standard base or deep base Signalling device is monitored Incorporates double switch short circuit isolator in sounder base and interface modules Interface module has fail safe operation
    Details
  • Key Features:; Complies to EN54 parts 3 100dB @ 1m sound output 16 tones can be selected from control panel Hard addressed via 8-way dip switch Can also be soft addressed via MKII handheld programmer Flush or surface fixing Housed in UL VO flame retardant ABS 4 x 20mm cable entries (2 top, 2 bottom) First fix, wire to back box technology
    Details
  • Key Features:; 101dB @ 1m sound output 16 tones can be selected from control panel White Flash rates between 0.33Hz and 1.5Hz Hard addressed via 8 way dip-switch Can also be soft addressed via MKII Handheld Programmer Flush or surface fixing Housed in UL V0 flame retardant ABS 4 x 20mm cable entries (2 top, 2 bottom) First fix, wire to back box technology
    Details
  • Wide 'all around' sound distribution Microphone self test facility Plug in base – no internal connections Up to 40 sounders directly on the loop wiring High efficiency sound gun transducer Synchronised outputs
    Details
  • Cost effective compliance with disability legislation Powered directly from the ZP loop Up to 20 devices directly on the loop wiring Low current LED based visual element High efficiency sound gun transducer Plug in base – no internal connections Minimises installation points
    Details
  • Key Features:; Detector and sounder from a single wiring point – minimising installation costs Powered directly from the ZP loop Up to 60 detectors with sounders directly on the loop Separate addresses selectable for detector and sounder High efficiency sound gun transducer Compatible with all ZP loop devices Wide range of international sound types and frequencies
    Details
  • Ziton ZP755B-2W Addressable Sounder Base (White); Sensor and sounder from a single wiring point - minimising installation costs Powered directly from the ZP loop Up to 60 sensor/sounders directly on the loop Separate addresses selectable for sensor and sounder High efficiency sound gun transducer Compatible with all ZP loop devices Wide range of international sound types and frequencies
    Details