/Apollo Fire Detectors
  • Key Features Allows multiple Interfaces to be housed together IP67 Rated
    Details
  • Key Features: Individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Tones can be used for other purposes in addition to warning of fire, making the device ideal for use in schools etc Soft start option, ideal for hospitals and nursing homes Group and global control for increased response time
    Details
  • Apollo Discovery Manual Call Point A seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated, the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.
    Details
  • Key Features: Flashing LED option to indicate polling (Discovery systems only) Plug and Play terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
    Details
  • Key Features: It is possible to set individual control of the sounder and visual indicator Volume and tone settings can be selected from the control panel Electronic bell tone IMO 1A tone included
    Details
  • Key Features: Resettable operating element Easy access, front reset mechanism Front facing accessible addressing for commissioning Ergonomic reset key and keyring hole Flashing Poling LED Option 170 viewable LED indicator
    Details
  • Key Features: Approved for use in the marine environment Five response modes for environmental adaptation Day/night switching for increased flexibility Drift compensation for false alarm reduction User programmability for data XPERT card addressing for increased security
    Details
  • Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
    Details
  • Key Features: Four pre-set message pairs Capable of up to 15 tone message pairs Low current and high volume Fully synchronised Set up and test at point of installation
    Details
  • Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb EE tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
    Details
  • Key Features: ATEX & IECEx certified: II2GD Ex d IIC T4 Gb Ex tb IIICT135 ?C Db IP66 A21 (Zones 1, 21, 2 and 22) Selectable output options: Conventional two-wire, 4-20mA, Latching or Non-latching, Relay Contacts - Fire/Fault, Pre alarm Class 1 sensitivity to EN54-10 detects 0.1m2 fire at 25m High optical interference immunity Selectable response speed Optical self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
    Details
  • Key Features: ATEX Certified: II 2 G D CENELEC/IEC Certified: EEx d - IIC T6- (Zones 1, 21, 2 and 22) Class 1 sensitivity to EN54-10 detects 0.1m2 fires at 25m Highest optical interference immunity Selectable output options: Conventional two-wire, 4-20mA, Relay Contacts - Fire/Fault, Pre alarm, Latching or Non-latching Selectable response speed Remote control self-test Low power consumption IP66 rated Supply voltage 14 to 30Vdc Operating temperature -10C to +55C
    Details