DPK6 for use with Generation6 multi-sensor detectors 850PH and 830PH with built-in 4B-C 4†Continuity Base Designed to comply with EN 54-27 One-pipe air sampling system Patented venturi pipe and duct housing Test hole on cover Simple installation Simple service and maintenance
-
Photoelectric, integrated low-flow technology Air velocity rating from 1.5m/s to 20.3/sec Versatile mounting options: square or rectangular configuration Broad ranges for operating temperature – 20 to 70 degree and humidity 0-95% (non-condensing) Patented sampling tube installs from front or back of the detector with no tools required New cover temper signal Increased wiring space with a newly added 20mm conduit knockout Available space within housing to accommodate mounting of relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection
-
-
1 - 4 Individual detectors per aspirator (providing up to 4 separately identifiable areas) High performance optical ‘Scatter Chamber Detectors’ (SCD) or High performance optical ‘Scatter Chamber Detectors’ (SCD) and enhanced CO detection Multiple language, multi-function LCD display Simple install and commission process without the need for a laptop connection Simple Class A, Class B, Class C and Prison sensitivity configuration set up Inbuilt algorithm to avoid unwanted alarms Airflow monitoring per pipe; Class A - High Sensitivity Applications include: Small Computer Rooms, Cleanrooms, Data Centres, Control Rooms, Archive Storage & EDP areas Class B - Enhanced Sensitivity Applications include: Small Historic Buildings, Museums, Theatres, Galleries, High Ceiling Areas, Small Clean Warehouses & Small Atria Areas Class C - Normal Sensitivity and Harsh Environment Applications include: Lift/Elevator Shafts, Small Cold Storage Facilities, Clean Warehouses, Atria, Inaccessible Voids & Up to 4 x separately identifiable Prison Cells per aspirator.
-
Cirrus Pro Series Remote Display Programmer. Multifunction Quarter VGA back lit LCD and programmer. Remote detector ‘Silence’ and ‘Reset’ buttons. May be networked with other Cirrus Pro Series aspirating detectors.
-
Unique Cloud Chamber Detection Principle Easy to Operate Completely Self Contained Locate potential fire threats from early warning alarms May be used in conjunction with any fixed air sampling system Multi-function LCD Display 10 Sensitivity Settings 4 Alarm Levels Fault diagnostic feature Includes sample probe and battery charger Immune to dust, humidity and temperature changes
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four ‘individually identifiable’ sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. Multifunction Quarter VGA back lit LCD and programmer. May be networked with other Cirrus Pro Series aspirating detectors
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. Multifunction Quarter VGA back lit LCD and programmer. May be networked with other Cirrus Pro Series aspirating detectors
-
Cloud Chamber Detection Principle Up to 200 mtrs Sampling Pipe Programmable ‘Pre-Alarm’ warning condition 3 Programmable ‘Fire’ warning conditions Airflow Monitoring ‘Fault Diagnostic’ feature Immune to dust, humidity & temperature changes EN54-20 Approved
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. May be networked with other Cirrus Pro Series aspirating detectors
-
Cloud Chamber’ aspirating fire detector For use with up to a total of 100mtrs of 25mm diameter sampling pipe. Single sampling pipe ‘inlet’ port, single sampling pipe ‘exhaust’ port LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button May be networked with other Cirrus Pro Series aspirating detectors
-
The first and only ‘Combined Fire & Smoke’ Aspirating Detector Unique ‘Cloud Chamber Detection’ (CCD) - primary detection technology Optical ‘Scatter Chamber Detectors’ (SCD) - secondary detection technology Independent and integrated intelligent alarm signal decision making The largest sensitivity range aspirating detector Zero% obs/m to 20% obs/m HYBRID ‘Smart Signal‘ to verify alarms and discriminate false alarms 7†full colour multi-function touch screen LCD display Live camera stream from up to 6 IP colour cameras On-board animated fault diagnosis feature
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
1 sampling pipe/1 detector EN 54-20 classes A, B, and C 5 alarm levels (3 pre-alarms and 2 alarms when using RIM36 Module) Response sensitivity settable from 0.002–10%/m Insensitive to dirt particles thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Perfected smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption ASD Config PC tool ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
-
1 sampling pipe / 1 detector EN 54-20 classes A, B, and C 4 alarm levels (1 fire alarm, 3 fixed pre-alarms 30 / 50 / 70% when using RIM36 Module) Response sensitivity settable from 0.006–10%/m Insensitive to dirt particles due to particle suppression Low noise level, compliant with ISO 11690-1 Perfected smoke detection with HD sensor (high-dynamic technology) Low power consumption Onboard Configuration ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure