/Aspirating Smoke Detectors
  • High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
    Details
  • Photoelectric, integrated low-flow technology Air velocity rating from 1.5 m/s to 20.3 m/sec Versatile mounting options in square or rectangular configuration with modular construction Plug-in sensor Superb false alarm immunity with the latest sensor technology Broader ranges for operating temperature (-20ºC to 70ºC) and humidity (0% to 95% non-condensing) Patented sampling tube installs from front or back of the detector with no tools required A cover tamper feature to indicate a trouble condition for removed or improperly installed sensor cover Increased wiring space with 15mm and 20mm conduit knockout Improved LED status 24 VDC Backward compatibility with existing DH400 range, including remote accessories
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • High sensitivity LED Detection Chamber specially designed to cover Class C. Includes a high power output IR LED and high gain IR receiver amplifier Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Provides pre-alarm functionality for graduated alarm thresholds Ultrasonic airflow sensing with expanded monitoring range A single device covers up to 2,000m2 according to national design regulations Pipe-IQâ„¢ software provides intuitive system layout and configuration all in one package Whisper-quiet 26db(A) fan; ideal for discrete detection monitoring Multiple event logging up to 2244 events User friendly air flow pendulum graph for verification of pipe network functionality Easily replaceable and reusable filter without affecting the rest of the device Protected electronics from air flow and accidental damage during installation or maintenance Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required Easy access to parts requiring routine maintenance: filter(s) and sensor(s) IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Single & Dual channel versions with independent channels including fan, sensor, and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance IP65 enclosure
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes – each up to 50m in length Uses conventional or analogue addressable detectors (not supplied) Detection element can be serviced or replaced Rugged IP65 enclosure
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details
  • Economical, single or dual area aspirated ‘fire’ detection 1 or 2 sampling pipes - each up to 100m in length Coverage up to 1,500m at class C 3 users configurable alarm levels per channel Integral Display and Programmer Rugged IP65 enclosure Single, redundant or coincidence detection strategies
    Details