-
Patented venturi pipe and duct housing One-pipe air sampling system Uniguard Superflow New cross-section (shape) of the venturi pipe gives an optimum of venturi effect Test hole on cover Simple installation Sensitive flow indicator Simple service and maintenance Installer-friendly connection of cables Foolproof installation of venturi pipe
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
-
Single & Dual channel versions with independent channels including fan, sensor and flow monitoring Multiple event logging up to 2240 events Ultrasonic airflow sensing PipeIQâ„¢LT software provides intuitive system layout and configuration all in one package User friendly air flow pendulum graph for verification of pipe network functionality Protected electronics from air flow and accidental damage during installation or maintenance Easily replaceable and reusable filter without affecting the rest of the device Designed for efficient wiring and installation: cable gland holes, easy access to the wiring area and no special tools required. Easy access to parts requiring routine maintenance: filter(s) or sensors(s). IP65 enclosure
-
1 sampling pipe / 1 detector EN 54-20 classes A, B, and C 4 alarm levels (1 fire alarm, 3 fixed pre-alarms 30 / 50 / 70% when using RIM36 Module) Response sensitivity settable from 0.006–10%/m Insensitive to dirt particles due to particle suppression Low noise level, compliant with ISO 11690-1 Perfected smoke detection with HD sensor (high-dynamic technology) Low power consumption Onboard Configuration ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
-
1 sampling pipe/1 detector EN 54-20 classes A, B, and C 5 alarm levels (3 pre-alarms and 2 alarms when using RIM36 Module) Response sensitivity settable from 0.002–10%/m Insensitive to dirt particles thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Perfected smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption ASD Config PC tool ASD PipeFlow calculation tool Individually Replaceable Components (Sensors, PCB’s etc)
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
6000PLUS/UG4DP for use with Protec Algo-Tecâ„¢ 6000 Interactive Digital Addressable Fire Detection Systems One-Pipe Air Sampling System Patented Venturi Pipe and Duct Housing Test Hole on Cover Simple Installation Sensitive Flow Indicator Filter for Dusty Environments Foolproof Installation of Venturi Pipe
-
Cloud Chamber’ aspirating fire detector For use with up to a total of 100mtrs of 25mm diameter sampling pipe. Single sampling pipe ‘inlet’ port, single sampling pipe ‘exhaust’ port LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button May be networked with other Cirrus Pro Series aspirating detectors
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. May be networked with other Cirrus Pro Series aspirating detectors
-
Cloud Chamber Detection Principle Up to 200 mtrs Sampling Pipe Programmable ‘Pre-Alarm’ warning condition 3 Programmable ‘Fire’ warning conditions Airflow Monitoring ‘Fault Diagnostic’ feature Immune to dust, humidity & temperature changes EN54-20 Approved