- Single Compact Housing
- Area coverage 50 metre or 100 metre model available
- 12-24 Vdc Operation
- Low current Consumption
- Robust Construction
- Conforms to: BS5839 Part 5 and EN54 part 12, UL and VdS
-
Key Benefits
-
Key Benefits:
- Integrated visible laser and auto-alignment for ultimate ease of alignment
- One standalone product – no specialist tools required
- Prevent nuisance alarms with Light Cancellation Technology™ which compensates for sunlight and artificial light sources
- One person installation – everything can be done by one person
- Contamination Compensation to correct for gradual build-up of dust on optics
-
Key Benefits
- Up to 2 optical beam detectors per system controller
- Easifit Fix System
- Ground Level Control
- Laser Assisted Alignment
- Auto-Optimise Beam Alignment
-
Approvals:
- II 2 GD
- Ex db op is IIC T6 Gb
- Ex tb IIIC T85°C Db
- Ta = 20°C to +55°C
- Self check and automatic compensation
- Robust metal construction
-
Key Benefits
- Allows for 2 Detectors per System Controller
- Range 5 to 120 metres, configurable per set of Detectors
- Integral Laser Alignment in Receiver
- 2-wire Interface between Controller and Receiver
- Seperate Fire and Fault Relays per Detector
-
Key Features:; Loop Powered and compatible with XP95, Discovery and CoreProtocol* Incorporates a bi directional short-circuit isolator Automatic drift compensation Automatic reset Ground level Controller Automatic alignment compensation for building movement Laser assisted alignment for quick installation Allows for 2 detector heads per controller Up to 100m range Pre-alarm threshold EN 54-12 and EN 54-17 certified
-
One Minute Auto-Alignment – The Fireray One’s one-minute auto-alignment feature not only saves time during installation, the quality of alignment is also guaranteed by the automation protocol. Using the Fireray One, a high level of protection is always achieved. One standalone product – The Fireray One is a standalone reflective beam detector that requires no specialist tools or prior knowledge or training to get it up and working. One personal installation – All of the internal and external features of the Fireray One ensure that anyone can align the beam detector perfectly, because the experience and expert knowledge of beam detection has been engineered into the product! Movement Tracker – The Fireray One contains Building Movement Tracking that maintains its own alignment once installed. Its optics are fully enclosed in an IP-rated casing with a flat surface for easy cleaning without affecting alignment. An integrated user-interface at the front of the product allows realignment and programming without having to dismount the detector.
-
commission the beam from ground level manually move the beam head view the air quality view the status of the beam change sensitivity thresholds change the time to fire and fault make the alarm latching or non-latching turn on and off the green flashing light see fire and fault counts see how much compensation has been made for dirt build up (you will only have to clean the head and reflector when it needs it) complete a self-test turn the beam on and off (it will reset itself after 8 hours) adjust output and receiver settings and even monitor the temperature at the beam head
-
New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place.
-
Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction Conforms to: BS5839 Part 5 and EN54 part 12, UL and Vd
-
Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction Conforms to: BS5839 Part 5 and EN54 part 12, UL and Vd
-
Auto-compensates for building movement and contamination Integral laser and auto-align enable quicker installation Low-level system controller with LCD display and user-friendly interface
-
Auto-compensates for building movement and contamination Integral laser and auto-align enable quicker installation Low-level system controller with LCD display and user-friendly interface
-
Full icon-based, easy-to-use LCD display on the low level controller for ease of commissioning, testing and maintenance Aesthetically pleasing to suit modern architectural buildings and heritage sites Range 5 to 120 metres Laser assisted alignment combined with easy to use alignment LED's enables installation by one operator Separate Fire/Fault Relays per Detector Selectable sensitivity/threshold levels Automatic Gain control (AGC) for drift compensation
-
Continually corrects itself against building movement Controlled and adjusted from ground level Use XP95 Switch Monitor to interface it to an addressable loop
-
Loop-powered Compatible with Discovery and XP95 protocols Incorporates a short-circuit isolator Automatic drift compensation Automatic reset following alarm or fault condition
-
Loop Powered 2000 series protocol Area coverage up to 600 m² Range from 5 - 50 m and 50 - 100 m Up to ceiling heights of 25 m Low current consumption 3 selectable alarm thresholds Self-check and automatic contamination compensation Automatic discrimination between fire and fault Vertical or horizontal mount Easy wiring and unique alignment Microprocessor controlled Conforms to BS5839 part 5 and EN54
-
Loop Powered 2000 series protocol Area coverage up to 600 m² Range from 5 - 50 m and 50 - 100 m Up to ceiling heights of 25 m Low current consumption 3 selectable alarm thresholds Self-check and automatic contamination compensation Automatic discrimination between fire and fault Vertical or horizontal mount Easy wiring and unique alignment Microprocessor controlled Conforms to BS5839 part 5 and EN54
-
Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction
-
-
Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Approved to EN54:12 and UL268
-
-
Allows for 2 Detectors per System Controller Each Detector configurable from 8m to 100m Separate Fire and Fault relays per Detector Integral LASER alignment Auto-Align Fast Automatic Beam Alignment Building Movement and Contamination Compensation Low Level System Controller Logs the 50 most recent events per detector Programmable Sensitivity and Fire Thresholds 20mm Cable Gland Knockouts on System Controller 2-wire interface from System Controller to Detector
-
Single Compact Housing Area coverage 50 metre or 100 metre model available 12-24 Vdc Operation Low current Consumption Robust Construction
-
Loop powered Soft addressed Integral short circuit Isolator Single address Reflective beam detection Quick and simple to setup Saves on both time and installation costs No power supply required Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance, especially in warehouses with racking; 1 x Detector Head Assembly 4 x Prism for the MAB100R 1 x Dual Test Filter 1 x 4-way Connector for in line wiring 1 x 4-way Connector for right angle wiring
-
Loop powered Soft addressed Integral short circuit Isolator Single address Reflective beam detection Quick and simple to setup Saves on both time and installation costs No power supply required Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance, especially in warehouses with racking; 1 x Detector Head Assembly 1 x Prism for the MAB50R 1 x Dual Test Filter 1 x 4-way Connector for in line wiring 1 x 4-way Connector for right angle wiring
-
Quick and simple to install Simple two wire connection No power supply required; Benefits; Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance
-
Quick and simple to install Simple two wire connection No power supply required; Benefits; Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance
-
Range of 10-100 metres Low current consumption Automatic self-check drift compensation Ground level control unit Complies with BS5839 part 5
-
Continually corrects itself against building movement Controlled and adjusted from ground level utilising included controller 5 to 40 m standard detection range Extensions kits available to enhance detection range up to 100 m Fully compatible with the Hochiki ESP analogue addressable protocol
-
New Revised Optics: This new design incorporates all the leading features we have honed over the years and with the latest advanced components we have produced a VdS approved fully compliant to EN 54-12:2015 beam detector that out performs all other beams in the market place. Five Times Faster: We have designed completely new linear stepper motors which have resulted in amazingly fast commissioning and routine maintenance. Under test conditions at 40 metres we recorded an auto-align time of 3m02s using the Fire Beam straight out of the box. Once aligned a routine re-alignment was timed at just 1m07s. This is class-leading performance not only in terms of speed but also in terms of advanced robust design built for precise purpose. Multi Language Support: The Fire Beam Xtra has the ability to display seven different languages: English, German, Spanish, French, Italian, Dutch, and Czech. A feature that is welcomed by our ever increasing international customers as we now sell to 62 countries around the world. Auto-Align On/Off: Although rarely needed, this facility allows you to turn off the auto-alignment in normal service, should the environment be liable to occasional contamination (such as theatres with fake smoke). As motorised beams work by seeing the reflector, if they are unable to because of unavoidable obscuration they can fall out of alignment when trying to find the obscured reflector. The Fire Beam Xtra will remain in perfect alignment in these environments simply by not trying to re-align itself. Auto-alignment will still continue to work in commissioning modes. This facility is best suited to beams that are mounted on solid surfaces that are not susceptible to building movement at all. For buildings that are liable to movement (such as metal warehouses) we have also built in a new delay function that can be used instead (see below). Auto-Align Time Delay: Again this facility is useful in environments that are liable to occasional short term obscuration. Adding a delay means that the beam will not check for alignment if the received signal drops for a predetermined time. Pre-set at 4 hours this can be altered to anywhere between 0 to 12 hours if required, to allow the environment to clear. Beam Phasing: It is possible that beams that face each other will cause problems as their sample rates could coincide and result in unreliable readings, meaning false auto-alignment and unreliably in service. With the introduction of phasing it is now possible to mount beams facing each other with reflectors in between. There are up to 7 different sampling rates to choose from, alleviating any cross talk problems. Hysteresis: Changing the hysteresis will change the delay in returning from a fire state back to a normal state. For example, the beam is factory set at 15% so if the beam falls into fire at 65% (35% threshold) it has to recover 15% to 80% before it returns to normal. This action prevents small fluctuations in returned signal causing the beam to fall in and out of a fire state. This can be adjusted to anywhere between 1% and 40%. The hysteresis can simply be adjusted from this new menu option. Up to 160 Metre Range: With new enhanced optics you can cover distances up to 160 metres, meaning for distances over 100 metres you no longer need to use two beams, saving both time and money. Very Low Power: using only 3.5mA any state opens up a whole world of options. In some cases you can loop power the beam, for instance using an Apollo xp95 mini switch monitor allows you do just that and turns the conventional Fire Beam into an addressable unit. IP65: means no ingress whatsoever making The Fire Beam ideal for environments, such as food processing halls, as it can be hosed down. IP65 also means nasty little creatures can't set up home inside and jeopardise the effectiveness of the detector. Easy Clean Lenses: The Fire Beam has been designed to be easily cleaned due to its flat surfaces. Unlike other beams all the moving optics are safely encased inside the waterproof enclosure so you won't accidentally knock the beam out of alignment. This means The Fire Beam can easily be cleaned from ground level using something like a no-climb pole and suitable attachment.
-
12 and 24V operation Explosion Proof Transmitter and Receiver Units. Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordnance stores.
-
II 2 GD Ex db op is IIC T6 Gb Ex tb IIIC T85°C Db Ta = 20°C to +55°C; 12 and 24V operation Explosion Proof Transmitter and Receiver Units Low level Safe Area electronics Selectable sensitivity levels Low current consumption Self-check and automatic compensation Robust metal construction Ideal for the protection of large enclosures within hazardous areas in petrochemical plants, oil rigs, ordance stores; The Fireray® 3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. The Fireray® 3000 Exd optical beam smoke detector, together with a battery backed power supply, can be connected to a zone of a conventional fire alarm control panel or interfaced to an analogue addressable system via an addressable input module or a zone monitor module.
-
Separate Transmitter and Receiver Heads Range 5 to 120 metres, configurable per set of Detectors Integral Laser Alignment in Receiver 2-wire Interface between Controller and Receiver Single and Twin Detector options Separate Fire and Fault Relays per Detector Low Level Controller with LCD display Programmable Sensitivity and Fire Threshold Automatic Gain Control (AGC) for drift compensation First Fix concept for Transmitter, Receiver and Controller Multiple cable gland knockouts for ease of wiring Optional Transmitter powering from Controller 5-year Warranty
-
Up to 2 optical beam detectors per system controller Easifit Fix System Ground Level Control Laser Assisted Alignment Auto-Optimise Beam Alignment Contamination Compensation Building Shift Compensation Approved to EN54:12 and UL268
-
Up to 2 optical beam detectors per system controller Easifit Fix System Ground Level Control Laser Assisted Alignment Auto-Optimise Beam Alignment Contamination Compensation Building Shift Compensation Approved to EN54:12 and UL268