Nittan RP-RS1-01/NTN Surface Mounting Reset Call Point IP24; EN54-11 approved (Cert No. 653a/01) Glass appearance maintains operator deterrence Positive activation that mimics the feel of breaking glass Visible warning flag confirms activation Simple key to reset operating element – no broken glass No glass elements to break lose or incorrectly fit during installation Complete functional test with every activation Extremely attractive, high value look and feel Low profile, heavy-duty terminations – Two built-in resistor values
-
Waterproof tested to IP67 Glass appearance maintains operator deterrence Positive activation that mimics the feel of breaking glass Visible warning flag confirms activation Simple key to reset operating element – no broken glass No glass elements to break, lose or incorrectly fit during installation Complete functional test with every activation Extremely attractive, high value look and feel Low profile, heavy-duty terminations – two built in resistor values
-
Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics Fully approved to the latest standards Backward compatibility CPD Approved
-
Key Features:; Unique ‘Plug & Play’ installation concept Total ‘Flex-Ability’ in the choice of operating element Anti-Tamper facility Enhanced aesthetics Fully approved to the latest standards Backward compatibility CPD Approved
-
-
-
Apollo Series 65 Conventional Manual Call Point – 55200-001APO; Resettable element for testing Selectable 470 or 680 resistors Easy access, front reset mechanism EN54-11 Approved (Red version only)
-
-
-
Key Features; Resettable operating element Easy access, front reset mechanism Ergonomic reset key Double pole change-over contacts Suitable for semi flush or surface mounting Optional transparent hinged cover
-
Operation; 'Plug and play' terminal connections for fast wiring Resettable element
-
Apollo Series 65 Outdoor Manual Call Point without LED - 55200-003; APO; Resettable element for testing Selectable 470? or 680? resistors Easy access, front reset mechanism EN 54-11 Approved
-
Key Features:; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch Fully approved to the latest standards
-
Key Features:; Easy to install With break glass or resettable element Easy to replace glass High quality micro switch IP67 rated EN54-11 & CPD approved
-
Key Features:; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch Fully approved to the latest standards
-
Key Features:; Easy to install With break glass or resettable element Easy to replace glass High quality micro switch IP67 rated EN54-11 & CPD approved
-
-
Certified to EN54 Part 11 (LPCB/VdS). Unique ‘Plug & Play’ installation concept. Supplied with a non-breaking plastic resettable element. Includes a 470? resistor, test key and red back box. Anti-Tamper facility. Flush version (without a red back box) also available (order code BF370MFR).; Technical Specification; Approvals/certifications - Certified to EN54 Part 11 by the LPCB & VdS. Supply/operating voltage - 30Vdc max. Product dimensions (mm) - 93 W x 89 H x D 60mm (includes back box). 28mm D without back box. Construction & finish - Red ABS. Plastic element. IP Rating - IP24D. Weight -180g (130g without back box). Properties - Supplied with a 470? resistor. Operating conditions/temperature - -10ºC to +55ºC.
-
Key Features; For use with ceiling mounted ActiV or CAST devices on retrofit installations. Helps cover the decorating marks left by older Grade D domestic type systems. Includes multiple mounting holes and large cable entry section.; Compatibility - Compatible with C-TEC's ceiling mounted ActiV and CAST range of fire alarm devices. Construction & finish - Durable white polycarbonate, Width - 152mm diameter.
-
Certified to EN54 Parts 11 (LPCB) and 13 (BSI). Smooth-action resettable element mimics the feel of breaking glass. Supplied with a red back box, reset key and ‘Not in Use’ label. Red LED ‘alarm ring’ illuminates call point face upon activation. Photoluminescent operating window remains visible for up to 5 minutes. Note an additional BF370SFP white flush mounting plate is required if you wish to flush mount the BF370S/W Waterproof/ Weatherproof; Technical Specifications; Approvals/certifications - Certified to EN54 Parts 11by the LPCB and 13 by the BSI. Supply/operating voltage - 4.5-30Vdc Product dimensions (mm) - 87 W x 88 H x D 62mm (includes back box). Construction & finish - Red ABS. IP Rating - IP42. Properties - Supplied with a 470? & 680? resistor (value selected by wiring connection) Operating conditions/temperature -30ºC to +70ºC.
-
Certified to EN54 Part 11 (LPCB/VdS). Unique ‘Plug & Play’ installation concept. Supplied with a glass element. Includes a 470? resistor, test key. Anti-Tamper facility.
-
Certified to EN54 Part 11 (LPCB/VdS). Weather resistant and sealed to IP67. Ideal for use in external environments where water and dirt are likely to be present. Unique ‘Plug & Play’ installation concept. Supplied with a glass element. Includes a 470? resistor and test key. Anti-Tamper facility. Wide -25ºC to +70ºC operating range.; Technical Specifications; Approvals/certifications - Certified to EN54 Part 11 by the LPCB & VdS. Supply/operating voltage - 30Vdc max. Product dimensions (mm) - 93 W x 97.5 H x D 71mm. Construction & finish - Red PC/ABS. Ral 3001. Glass element. IP Rating - IP67. Weight - 350g (130g without back box). Properties - Supplied with a 470? resistor. Operating conditions/temperature -25ºC to +70ºC.
-
Benefits and Features:; Approved to EN54 -11 Convenient clip fixed front cover One key for test and cover removal Available as weather proofed
-
Key Features:; Proven design, approved and certified to EN54-11 Secure & convenient clip fit cover Use of glass or plastic resettable element without modification Superior LED alarm indication Back box WP version suitable for outdoor use MED certification