8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
8 Zone expandable control panels with a maximum of 16 zones 20 Zone expandable control panels with a maximum of 32 zones (Large Box version) Up to 32 conventional smoke and/or heat detectors per zone Zone expansion via 4 zone expansion module (GFE-EXP-MOD) Active or Resistive End of Line monitoring Programmable non-latching zones Programmable on/off delay timer per zone Programmable coincidence for adjacent zones One man test Supervised auxiliary 24 volt output 2 Supervised/ monitored sounder circuits 3 Programmable remote inputs. 2 Relay outputs 1 fire and 1 fault Fully EN54-2 and EN54-4 compliant Repeater output using RS232, RS485, Fibre Optic and TCP/IP
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
12, zonal, fire & fault indications 3 year warranty as standard Simple, colour coded buttons for controls Integral 1 amp switch mode PSU Class change & alert inputs Programmable outputs Test mode & disablement functions Fully functional or passive Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
16 - 32 zones 3 modes to manage false alarms Approved to EN54-2 & 4 3 year warranty Four monitored sounder circuits Class change & alert, programmable inputs Programmable relays & outputs Fire alarm routing output One man walk test Key-switch or code entry for activation of controls Fully functional LCD remote display units
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.
-
Haes 8 Zone Excel-EN Conventional / Twin Wire Control Panel with Standard Zone Card XLEN-8L; 2 - 12 zones 3 modes to manage false alarms Individually selectable Twin Wire zones Approved to EN54-2 & 4 3 year warranty Class change & alert, programmable inputs Programmable relays & outputs Modular expansion zone cards, including additional sounder circuits One man walk test Key-switch or code entry for activation of controls Fully functional repeater panels Two monitored sounder circuits fitted as standard.