/Addressable Fire Alarm Panel
  • Remote control and indication Up to 32 remote units connected to each main panel 4 rows 160-character LCD Replicates main panel fascia Restore disabled sounders facility
    Details
  • Single panel - stand alone concept Full ZP analogue addressable technology Complies fully with EN 54 parts 2 and 4 Advanced sensing techniques Loop powered sounders and beacons Radio/wireless detection interface
    Details
  • ZP analogue addressable system Complies fully with EN 54 parts 2 and 4 Advanced sensing techniques Extensive networking ability Loop powered sounders
    Details
  • Local or global repeater with or without global control functionality Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Comes standard fitted with network board
    Details
  • Local or global repeater with or without global control functionality Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Comes standard fitted with network board
    Details
  • Local or global repeater with Fire Brigade and Fire Protection controls with or without global control functionality Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Comes standard fitted with network board
    Details
  • Local or global repeater with Fire Brigade and Fire Protection controls with or without global control functionality Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Comes standard fitted with network board
    Details
  • Local or global repeater with or without global control functionality Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable cover and chassis for quick and clean installation All pluggable connectors 2 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Redundant 24VDC supply 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events DIN-rail mounting
    Details
  • Local or global repeater with Fire Brigade and Fire Protection controls with or without global control functionality Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable cover and chassis for quick and clean installation All pluggable connectors 2 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Redundant 24VDC supply 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events DIN-rail mounting
    Details
  • 2 loops with up to 128 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 2 loops expandable to 4 with up to 256 zones Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure with username and password History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 2 loops with up to 128 with Fire Brigade & Fire Protection controls zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 2 loops expandable to 4 with up to 256 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 1 loop with up to 64 zones Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure with username and password History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Key Features:; 1 loops with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • 1 loop with up to 64 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration and default EN54 setup modes Ethernet port with TCP/IP for remote maintenance and programming EN54 compliant graphical LCD with icons and symbols for easy recognition of events Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 user names and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the Ziton loop powered sounders/beacons and base sounders and Ziton series detectors
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizards and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Build-in thermal printer with paper replacement from the front 2 loops expandable to 4 with up to 512 zones with Fire Brigade & Fire Protection controls and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration, setup wizard and default regional setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 72 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
    Details
  • Remote control and indication Up to 32 remote units connected to each main panel 4 row 160 character LCD Replicates main panel fascia Restore disabled sounders facility
    Details
  • Key Features:; One or Two loop addressable fire alarm panel (64, 126 or 252 device capacity) Certified to EN54 parts 2 & 4 User definable zones Option for zonal or common alarm operation Options for I/O operation Alarm verification (help prevent false alarms) User selectable languages Set of changeover relay contacts for fault condition Set of changeover relay contacts for fire condition 2,048 event log (fire & fault) Zone or device disablement One-man test mode Plug & play, no need for any special tools or laptop for commissioning Fully integrated keypad All associated devices are loop powered
    Details
  • 1-4 loop, expandable by loop cards 20 zone LEDs 250 programmable zones Multi-language support (English, Spanish, Portuguese, French, Hungarian, Italian, Lithuanian & Dutch) Day/night mode delays 4 x 40-character LCD display Real Time Clock 4096 entry event logs 20-character device text 18-character zone text Zone or Device Disablement 2 x conventional sounder circuits Aux 24V supply 1 x fire relay 1 x fault relay Outputs programmable by zones Can be configured via PC or via Panel
    Details
  • From 1-2 Loops Compliant with EN54 parts 2 & 4, BS EN 60950 & BS EN 50130 part 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Voyager and Discovery panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives
    Details
  • From 1-2 Loops Compliant with EN54 parts 2 & 4, BS EN 60950 & BS EN 50130 part 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Voyager and Discovery panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives
    Details
  • Long term service and support Two way IR communications with Generation 6 Detectors reduces commissioning and service costs. Supports 1 MZX Digital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with “Front Panel Controls” to reduce lifetime cost of ownership Wide range of multi-sensor detectors including the 3oTec triple sensing detections. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 "Critical" Matching 16 Zone Fully Functional Mains powered Repeater Approved to EN54 the system is designed to be installed to BS5839
    Details
  • FIM800 field interface PCB incorporating one or two MZX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers LPCB, BV, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
    Details
  • EN54 Compliant MXDigital system Integral power supply Optional integral eighty way zonal LED’s Two to eight loops or network up to 396 loops 250 addresses per loop Full range of MZX virtual multi-sensor detectors MZX FASTLOGIC fuzzy logic smoke detection algorithms Fully functional repeater Powerful MXConsys & MXConsys Express configuration software Easy to install Space for 17Ah or 38Ah batteries
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
    Details
  • Long term service and support Supports 1 MXDigital loop with 250 addresses 2 KM loop length 32 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 32 Zone Fully Functional Mains powered repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839
    Details
  • Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool.
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details