Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Key Features:; Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Key Features:; Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
1 x Repeater Panel 1 x Back plane PCB including PSU 1 x Repeater CIE assembly 1 x Network card
-
2 or 4 loop versions as standard Larger enclosure available (fits 24A/H SLAs) Loopless panel option (repeater) 0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 64 panels/repeaters 4 programmable sounder circuits as standard 5.25 amp power supply to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Sensitivity adjustment and Drift Compensation Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility
-
Key Features:; Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
From 5-8 Loops LPCB approved to EN54 parts 2 & 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives 32 or 96 zonal fire and fault led indications
-
2 or 4 loop versions as standard Larger enclosure available (fits 24A/H SLAs) Loopless panel option (repeater) 0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 64 panels/repeaters 4 programmable sounder circuits as standard 5.25 amp power supply to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Sensitivity adjustment and Drift Compensation Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility
-
Key Features:; Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 2 x 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn and Loop Detection facility for trouble-free, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Ad-NeT network with up to 1000 zones.
-
2 or 4 loop versions as standard Larger enclosure available (fits 24A/H SLAs) Loopless panel option (repeater) 0, 16, 48, or 96 zone indicators Option for Enable Control keyswitch Fully supports Apollo, Argus Vega & Hochiki protocols Network up to 64 panels/repeaters 4 programmable sounder circuits as standard 5.25 amp power supply to EN54 part 4 Large graphic display In built help and alarm information screens Certified to EN54-2/ EN54-4 Real time clock Supports Apollo, Argus Vega and Hochiki loop powered sounders and beacons Sensitivity adjustment and Drift Compensation Stylish enclosure design Soft-touch tactile buttons 2 programmable function buttons 3 programmable front panel mounted LED’s Improved Front loading Printer (optional) Up to 512 programmable inputs/outputs per panel via 2 wire RS485 serial link (optional) Simple Windows® graphical configuration utility
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
From 5-8 Loops LPCB approved to EN54 parts 2 & 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives 32 or 96 zonal fire and fault led indications
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
From 5-8 Loops LPCB approved to EN54 parts 2 & 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives 32 or 96 zonal fire and fault led indications
-
Alarm Acknowledgement Sound Alarms Alarm Reset Alarm and Warning System Isolate Previous and Next – to scroll through faults and alarms; Key Features:; Up to 30 SmartTerminal’s can be connected to each FireFinder Fire Alarm Control Panel Large LCD with Backlight Internal Buzzer Flush or Surface Mountable Enclosure Control Enable Key Switch Controls have tactile and audible feedback Slimline version available
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
Key Features:; Fully expandable from 1 to 4 loops via common plug in loop driver boards. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 5 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Graphical display configurable for virtually any language When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full cross panel reporting, control functionality. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools.
-
From 5-8 Loops LPCB approved to EN54 parts 2 & 4 Full Apollo XP95 and Discovery compatibility Automatic recognition of Apollo or CEL outstations Extensive mode change options by day/night and special group allocation Windows based, full upload/download PC software package 500mA output per loop with highly stable voltage platform, even under mains failed conditions Fully networkable with other Discovery and Voyager panels, graphics package and Integra network repeaters Powerful processing and extensive panel and loop I/O capability User friendly controls and clear, unambiguous screen Membrane facia with tactile switches Complies with EMC and LVD Directives 32 or 96 zonal fire and fault led indications
-
1 x Repeater Panel Enclosure inc Back Box 1 x Back plane PCB including PSU 1 x Repeater CIE assembly 1 x Network card
-
Fully expandable from 1 to 2 loops via common plug in loop driver boards. Full support of Apollo (Discovery, Xplorer S90 & XP95), Hochiki ESP, Nittan Evolution and AV protocol. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 4 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Dual, flash based, microprocessor technology with on-board Real Time Clock. Optional on-board or remote printer. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Flash memory and the advanced graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full
-
Fully expandable from 1 to 2 loops via common plug in loop driver boards. Full support of Apollo (Discovery, Xplorer S90 & XP95), Hochiki ESP, Nittan Evolution and AV protocol. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 4 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Dual, flash based, microprocessor technology with on-board Real Time Clock. Optional on-board or remote printer. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Flash memory and the advanced graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full
-
Alarm Acknowledgement Sound Alarms Alarm Reset Alarm and Warning System Isolate Previous and Next – to scroll through faults and alarms; Key Features:; Up to 30 SmartTerminal’s can be connected to each FireFinder Fire Alarm Control Panel Large LCD with Backlight Internal Buzzer Flush or Surface Mountable Enclosure Control Enable Key Switch Controls have tactile and audible feedback Slimline version available
-
Fully expandable from 1 to 2 loops via common plug in loop driver boards. Full support of Apollo (Discovery, Xplorer S90 & XP95), Hochiki ESP, Nittan Evolution and AV protocol. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 4 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Dual, flash based, microprocessor technology with on-board Real Time Clock. Optional on-board or remote printer. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Flash memory and the advanced graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full
-
Fully expandable from 1 to 2 loops via common plug in loop driver boards. Full support of Apollo (Discovery, Xplorer S90 & XP95), Hochiki ESP, Nittan Evolution and AV protocol. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 4 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Dual, flash based, microprocessor technology with on-board Real Time Clock. Optional on-board or remote printer. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Flash memory and the advanced graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full
-
Key Features:; Fully expandable from 1 to 2 loops via common plug in loop driver boards. Full support of Apollo (Discovery, Xplorer S90 & XP95), Hochiki ESP, Nittan Evolution and AV protocol. Advanced graphical LCD user interface with up to 1000 fire zones as standard, allowing full EN54 compliance without additional hardware or LED indication. 4 Amp power supply and charger to EN54 part 4. Dedicated RS232 serial port for direct PC or modem connection. Dual, flash based, microprocessor technology with on-board Real Time Clock. Optional on-board or remote printer. Installer friendly Auto-learn and Loop Detection facility for troublefree, commissioning. Fully on-site programmable via on-board alphanumeric keypad or PC configuration tools. Flash memory and the advanced graphical display enables the panels to be configured to operate in virtually any language with any character set and allows the installer's logo and company details to be applied to the LCD display. Robust, removable equipment chassis with plug-in connectors for simple fixing and cable termination. When connected to the fault tolerant Ad-NeT network, the panel operates as a true peer-to-peer interface (with up to 1000 shared zones) with full