/Addressable Fire Alarm Panel
  • An EN54 approved networkable panel which can be configured with up to two detection loops, accommodating up to 200 devices per detection loop, this panel is an ideal solution for medium to large sites and campuses. 8 x 40 character LCD display Lockable outer door prevents tampering with controls Password protection of engineering functions LED indication of zones on fire
    Details
  • An EN54 approved single loop analogue addressable panel managing up to 127 devices. Ideal for small to medium sized businesses. Flush or surface mounted Configurations can be designed by using the offline function in the commissioning tool All detection and alarm devices connected to the same 2 core loop
    Details
  • Spare Key for SenTRI 2 and SenTRI 4 Outer Door (Pack of 10) Model: VS-KEY Shipping Weight: 200gms
    Details
  • Product Details; Model: SENTRI2-PSU-N Shipping Weight: 2000gms
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating two MX DIGITAL loops CPU800 32 bit processor and memory card Optional network card, additional loop card(s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists firefighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster FIM801CV field interface PCB incorporating one MX DIGITAL loop CPU800 32 bit processor and memory Card XLM800 loop expansion card containing two MX Digital loops Optional remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • Enhances fire detection and eliminates unwanted alarms using “fuzzy logic” Assists fire fighting and training by providing on-screen risk management information Helps fire crews by giving smoke density and temperature readings in the affected areas Simplifies maintenance by pin-pointing faults Enables remote fault finding to be carried out Flexible interfacing with graphic management systems
    Details
  • Long term service and support Supports 1 MXDigital loop with125 addresses 2 KM loop length 16 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 16 Zone Fully Functional Mains powered Repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839 Easy programming when using MXConsys Express configuration tool.
    Details
  • Long term service and support Supports 1 MXDigital loop with 250 addresses 2 KM loop length 32 way zonal LED display High level User Interface with "Front Panel Controls" to reduce lifetime cost of ownership Wide range of detectors including the 3oTec triple sensing detection. Early detection without false alarms. Wide range of ancillaries including door control to BS7273 category A Matching 32 Zone Fully Functional Mains powered repeater DDA compliance using the advanced 3000 series AV Base and loop powered sounder beacons. Approved to EN54 the system is designed to be installed to BS5839
    Details
  • PSB800 5A 24Vd.c. battery backed power supply and loop booster to EN54:pt.4 FIM800 field interface PCB incorporating one MZX DIGITAL loop CPU800 32 bit processor and memory card Optional network card, additional loop card (s) and remote diagnostic modem Optional IOB800 input/output expansion card mounted on the PSB800; Long term service and support Reliable, modular fire controllers BV, UL, VdS approved controllers, network, detectors and ancillaries Expandable from one 1 zone controller to multiple 240 zone, 1000 point controllers Easy to use with flexible and powerful configuration functions
    Details