1 loop with up to 512 zones and 300 output groups Up to 24 LED Zone indicators for Fire and Fault with space for a 4 digit number Auto configuration, setup wizards and default EN54 setup modes Ethernet port with TCP/IP for remote diagnostics, maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Jog Dail with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with special paintable synthetic door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support Email notification for events directly from the panel (4 user accounts) Auxiliary 24VDC supply output with reset support 3 operator level menu structure (20 usernames and passwords) History log memory for 9999 events Up to 24 hours standby time and 30 minutes alarm Compatible with the new loop powered sounders/beacons and base sounders and the 2000 series detectors with replaceable optical chamber
-
7-Segment display Remote test capabilities Remote signalling capabilities Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Polarity insensitive Full range including optical and multi sensors Full range of I/O units and accessories Isolator base EN54 and CPD certified VdS approved
-
Key Features:; Remote test capabilities Remote signalling capabilities Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Polarity insensitive Full range including optical and multi sensors Full range of I/O units and accessories Isolator base EN54, VdS and CPD approved
-
Optical smoke and heat detection Five modes of operation Independent control of detector modes Optical sensor with field exchangeable optical chamber Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Remote test capabilities Remote signalling capabilities Full range of sensors: optical and heat Full range of I/O units, MCPs and accessories
-
Remote test capabilities Remote signalling capabilities Field exchangeable optical chamber Easy numeric addressing (1-128) Enhanced communication protocol Full diagnostic self-testing Full range of detectors available Full range of I/O units and accessories Isolator base EN54:7 and CPD certified
-
Type B (double action) manual call point Includes dual isolator Complies to DIN14655 RED (alarm) and YELLOW (Isolated) LEDs
-
Addressable manual call point LED alarm indicator Tamper resistant break glass design Easy to test with auto reset Fast response IP67 waterproof model available
-
Type B (double action) manual call point Includes dual isolator Complies to DIN14655 RED (alarm) and YELLOW (Isolated) LEDs VdS Approved
-
Addressable manual call point LED alarm indicator Tamper resistant break glass design Easy to test with auto reset Fast response English, Dutch and French functional descriptions included
-
Addressable manual call point LED alarm indicator Tamper resistant break glass design Easy to test with self-reset Fast response IP67 (waterproof) Enhanced aesthetics and compact design Fully approved to the latest standards
-
Key Features:; Loop powered High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation CPD certified VdS Approved
-
Key Features:; Loop powered High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation CPD certified VdS Approved
-
Key Features:; Loop powered High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and beacons IP65 rated CPD certified
-
Key Features:; Loop powered High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation IP65 rated CPD certified
-
Key Features:; Loop powered High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation IP65 rated CPD certified
-
Key Features:; Loop powered Integrated isolator High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation CPD certified
-
Key Features:; Loop powered Integrated isolator High sound output with low current consumption Multiple tone selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation CPD certified
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs CPR certified to EN54:3 and EN54:23
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs IP65 rated CPR certified to EN54:3 and EN54:23
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs IP65 rated CPR certified to EN54:3 and EN54:23
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs CPR certified to EN54:3 and EN54:23
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs IP65 rated CPR certified to EN54:3 and EN54:23
-
Loop powered High sound output with low current consumption Multiple tone, output volume and varying flash frequency selection Suitable for multiple stage evacuation with up to 3 pre-set tones Automatic synchronisation for sounders and VADs IP65 rated CPR certified to EN54:3 and EN54:23
-
Key Features:; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch Fully approved to the latest standards
-
Key Features:; Easy to install With break glass or resettable element Easy to replace glass High quality micro switch IP67 rated EN54-11 & CPD approved
-
Key Features:; Enhanced aesthetics Easy to install (plug and play) Surface mount options Protection hinged cover with Anti-Tamper facility Backward compatible Key test facility May be used with glass or resettable element Easy to replace glass High quality micro switch Fully approved to the latest standards
-
Key Features:; Easy to install With break glass or resettable element Easy to replace glass High quality micro switch IP67 rated EN54-11 & CPD approved
-
Key Features:; Suitable for outdoor use Slim profile Low current consumption - 20mA Quick and easy installation Diode polarised Low maintenance Very reliable EN54-3 Approved CPD compliant
-
Key Features:; High sound output Low current consumption 32 Tones user selectable Automatic synchronisation Volume control Anti-Tamper locking mechanism Deep mounting base Wiring directly to base Two stage alarm VdS Approved
-
Key Features:; Universal fixing platform for detector bases Low current consumption Blank cover for use as a stand-alone sounder Reduced installation costs Two large cable entries High sound output Automatic synchronisation 32 Tones user selectable
-
Aritech 24V 2A + 0.8A EN54-4 Power Supply - PM702C; Approved to EN54-4 & VdS certified Self-contained box houses 17 Ah batteries Electronic overload protection Deep battery discharge protection Mains & Fault LED indicators Fault diagnostics led, inside of unit 2 x Relay outputs: Fault & Mains Fault Temperature compensated charging Wide input voltage range Start-up from batteries
-
Aritech 24V 5A + 1.6A EN54-4 Power Supply - PM705C; Approved to EN54-4 & VdS certified Self-contained box houses 17 Ah batteries Optional battery box houses 38 Ah batteries Electronic overload protection Deep discharge protection Mains & Fault LED indicators Fault diagnostics LED, inside of the unit 2 x Relay outputs: Fault & Mains Fault Temperature compensated charging Wide input voltage range Start-up from batteries
-
Key Features:; Wide operating voltage Low current consumption Universal mounting plate Low profile Clearly visible, large LEDs Protected against polarity reversal Connects up to 4 detectors Blinking or fixed LEDs High sound output With and without sounder
-
Key Features:; Wide operating voltage Low current consumption Universal mounting plate Low profile Clearly visible, large LEDs Protected against polarity reversal Connects up to 4 detectors Blinking or fixed LEDs High sound output With and without sounder
-
Key Features:; Easy to install Allows base sounder to be used as a normal sounder
-
Aritech External Battery Box for use with PM705C - PM700BAT; Approved to EN54-4 & VdS certified Support for 38 Ah batteries Temperature compensated charging