-
Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires PC based commissioning tools allow complex fire plans to be configured The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Vigilon allows full integration with Vigilon Voice alarm systems PC based Graphics user interface (GUI) available - Supervisor and WINMAG
-
Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires PC based commissioning tools allow complex fire plans to be configured The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Vigilon allows full integration with Vigilon Voice alarm systems PC based Graphics user interface (GUI) available - Supervisor and WINMAG
-
Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires PC based commissioning tools allow complex fire plans to be configured The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Vigilon allows full integration with Vigilon Voice alarm systems PC based Graphics user interface (GUI) available - Supervisor and WINMAG
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Key Features:; Easy to fit 65mm x Diameters x 1mm thick
-
-
-
-
-
-
Very low power consumption means more sounders and strobes per circuit The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power 32 sounder tones are available Voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard All sound and strobe signals are synchronised to better than +/-30mS over 20 minutes Sounders and strobes are compatible with 12V and 24V systems A third wired option allows the selection of 2 alternative sounds (ideal for class change applications) Products incorporate innovative design features for which multiple patents have been granted
-
-
Fully compliant with EN54, Part 11 Re-settable operating element option Weather proof IP67 Semi-flush or surface mounting 470 Ohm resistor and Normally Open contact complete with glass Resistive and clean contact connections
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Key Features:; Max Quantity per Loop – 100 Approx Weight – 0.34kg Operating Temperature – minus 10C to +50C Ingress Protection – IP40 Device Load Factor – 1
-
-
-
-
Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation
-
Very low power consumption means more sounders per loop e.g. 200 system sounders per loop compared to 40 The strobe option is equivalent to a standard 3w xenon strobe and uses 1/20th of the power The strobe element of the sounders is fully monitored for circuit failures The sounder tones are programmed in exactly the same way as the existing Vigilon sounders Loop powered voice enhanced sounders are available in the range 4 voice phrases and a bell sound are available as standard By using the bell sound in the voice sounder it is possible to have a loop powered bell The sound producing element in the voice sounders is monitored every hour using a VLF tone Voice and Tone mode can be freely mixed within the same sounder All messages and strobe signals are synchronised across loops in the same control panel Complements the S-Quad sensor with voice messages and complex sound signals A backwards compatible version of the system sounder is available for replacement or expansion to existing systems, avoiding the need to upgrade panel software The HandiLink remote control makes it much easier to adjust the sounders in situ Products incorporate innovative design features for which multiple patents are pending High intensity flashing strobe conforms to the Disability Discrimination Act (DDA) 1995 legislation
-
-
-
Key Features:; Ease of installation and a lot of space for wire connection Slide-easy base and elegant design with automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base One-way only fit
-
Gent Conventional Relay Detector Base 805591; Provides a voltage-free contact controlled by the remote output of a detector Draws negligible current A lot of space for wire connection Automatic closing of the loop bus wiring system for detector extraction Detector extraction locking is enclosed in the base
-
Key Features:; 3 continuously or pulsed LEDs Power-saving compact indicator
-
Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
-
Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
-
Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
-
Uniform response sensitivity of the detector for all different types of fire for the multi-sensor detectors Large distance between signal and interference magnitudes due to special sensor and electronics design for suppressing electromagnetic influences Automatic adaptation to varying environmental influences Electronic compensation of long-term influences of contamination or aging
-
Key Features:; Approved to EN54-3 Superior sound output and low current consumption 32 tones all approved to EN54-3 Adjustable volume settings Two stage sounders enable alert and alarm sequences to be set for phased evacuation Synchronised sound output
-
Key Features:; Approved to EN54-3 Superior sound output and low current consumption 32 tones all approved to EN54-3 Adjustable volume settings Two stage sounders enable alert and alarm sequences to be set for phased evacuation Synchronised sound output
-
Compatible with:; CRSO-WW-W1 CWSS-WR-W5 CWSS-WW-W5
-
Attention tones can be programmed either as a bell (on speech variants) or a choice of 12 standard tones Soft’ start option Uniform sound distribution Low current consumption Fully synchronised sound patterns via the panel Selectable speech messages available to suit most requirements – switched on/off by the Vigilon panel Rich harmonic sound output using patented technique Options for sound output: Standard mode = 90 dBA@1m (typical) Up to 98 dBA possible if required