/Morley
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps; Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Direct and reflected sunlight Artificial light, such as fluorescent tubes and glass covered halogen lamps Arcs and electric discharges (static or from e.g. electric motors) The radiation from electric welding provided that the electric welding takes place at distance more than 10 feet from the flame detector (a welding rod contains organic compounds which may produce a small flame); Morley Flame Detector - Data Sheet Morley Flame Detector - Technical Handbook
    Details
  • Patented WideBand IR™ technology Patented Electronic Frequency Analysis™ Visible sensor for optimum false alarm rejection Selectable detection sensitivities Field-of-View: 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — pre-fire event data storage Event log with date and time stamp RS-485 ModBus communication Non-Isolated 4-20 mA Analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic optical path and electronic self-test Patented Electronics Module for components protection with easy plug-in terminations and field installation Two M25 conduit entries Low power consumption High RFI and EMI immunity; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° field of view Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two M25 conduit entries Low power consumption; Morley Flame Detector - Data Sheet Morley Flame Detector - Installation Guide
    Details
  • Patented WideBand IR™ Infrared combined with Ultraviolet Detection range greater than 60 m (200 feet) to 0.1 m2 (1 sq. ft.) heptane fire Patented Electronic Frequency Analysis Visible sensor for optimum false alarm rejection Selectable detection sensitivities Solar blind 90° cone-of-vision Dual microprocessors for reliable performance Real-time clock for accurate time dating of events FirePic™ — Up to 6 pre-fire event data storage Event log — Up to 200 events with date and time stamp Built-in RS-485 ModBus communication Built-in non-isolated 4-20 mA analog output (sink or source) Alarm, Fault and Fire Verification relays Automatic Optical Path and Electronic self-test Patented Electronics Module for component protection with plug-in terminations for easy field installation Two 25 mm conduit entries or two ¾” NPT Low power consumption High RFI and EMI immunity FM hazardous area approved Ex d ATEX approved CU-TR approved INMETRO approved Meets SIL 2 requirements Certified to EN54-10:2002 (option) FM 3260 performance; Refineries and oil production facilities Off-Shore platforms Turbine/Compressor enclosures Acetylene processing and storage Oil and Gas pipelines and pumping stations LNG/LPG loading and unloading facilities Natural Gas and CNG plants Ethanol, Methanol, and IPA production and storage Crude oil and gasoline storage and tank farms Aircraft hangars Hydrogen plants and storage Paint and solvent storage Chemical production, storage, and loading facilities Power plants Silane gas storage; Morley FS20X-211-24-6 - Data Sheet Morley FS20X-211-24-6 - Installation Manual
    Details
  • Morley Call Point - Data Sheet BS5839-2017 Call Point Covers Information Sheet
    Details