/Apollo Fire Detectors
  • Key Features: modern styling loop-powered interface operating on 868MHz wireless addresses seen by control panel as normal addresses radio base with wireless circuitry and battery compartment chamber designed to inhibit dirt penetration and thus reduce false alarms automatic drift compensation with DirtAlert warning algorithms for transient alarm rejection FasTest reduces time taken to test detectors remote test facility 3-5 years battery life
    Details
  • Key Features: Indicates the suitability of proposed device location
    Details
  • Protocol Translators are installed in the safe area ensuring integrity of communication between control equipment and field devices and safety within the limits of BASEEFA approvals
    Details
  • Key Features: XP95, Discovery and CoreProtocol compatible Responds well to slowburning, smouldering fires Well-suited to bedrooms and escape routes Unaffected by wind or atmospheric pressure Other part codes include: AD-2000
    Details
  • Key Features: Plug and Play terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
    Details
  • Key Features: Sensitive to a wide range of fires Well suited for environments such as hotel bedrooms Unaffected by wind or atmospheric pressure Other part codes include: AD-2004
    Details
  • Key Features: Provides a set of voltage free contacts controlled by the remote output of a detector. Draws negligible current Capable of switching up to 30V at 1A
    Details
  • Key Features: High intensity LEDs More reliable than xenon visual indicators Automatic LED check Lockable Wide angle of visibility Enables DDA compliance Synchronised flash Can be used with Discovery or XP95
    Details
  • Key Features: Robust design Waterproof Reports an alarm in under 0.2 seconds
    Details
  • Key Features: Operates in air speeds of 0.5m/s to 20m/s Transparent cover to view detector head LED Integral smoke test port
    Details
  • Key Features: Detects a wide range of fires. Insensitive to wind. Transient voltage protection. Fine gauze insect protection. Simple construction allows detection chamber to be cleaned. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator. Responds well to slowburning, smouldering fires Well-suited to escape routes Unaffected by wind or atmospheric pressure
    Details
  • Key Features: Reports an alarm in under 0.2 seconds Waterproof / weatherproof IP67 Designed for ?explosive mixture atmosphere
    Details
  • Key Features: Plug and Play terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
    Details
  • Key Features: Detects super heating and flaming combustibles. Dual chamber technology. Wind resistant smoke inlets. Transient voltage protection. Fine gauze insect protection. Lockable security fitting. Must be connected to a suitable safety barrier and protocol translator.
    Details
  • Key Features: Rate of rise and fixed temperature alarm point. Single thermistor technology. Transient voltage protection. Resettable operation. Lockable security fitting. Please Note: Must be connected to a suitable safety barrier and protocol translator
    Details
  • Key Features: Ideal in environments that are dirty or smoky under normal conditions Well-suited to warehouses, loading bays and car parks Unaffected by wind or atmospheric pressure Other part codes include: AD-2002
    Details
  • Key Features: Robust design Waterproof Reports an alarm in under 0.2 seconds
    Details
  • Key Features: Ideal in environments that are dirty or smoky under natural conditions Well suited for warehouses, loading bays and car-parks Unaffected by wind or atmospheric pressure
    Details
  • Key Features: Visual indicator flash rate of once per second Synchronisation of visual indicator flash Individual and group addressing Unique visual indicator self-test Loop-powered Built-in Isolator
    Details
  • Key Features: For use on an XP95 / Discovery system Sound output of 85dB(A) at 1 metre Current consumption of only 3mA Loop-powered Responds to signals from the associated detector ? does not have an address of its own Adjustable volume control IP23D rated
    Details
  • Key Features: Choice of tones on standard device: Apollo, Slow Whoop, and DIN IP66 rated Two Volume settings 92dB(A) and 100dB(A) Synchronisation of 'alert' and 'evacuate' tones Individual and group addressing Built in isolator
    Details
  • Key Features: Choice of tones on standard device: Apollo, Slow Whoop and DIN Two volume settings 92dB(A) and 100dB(A) Synchronisation of 'alert' and 'evacuate' tones Individual and group addressing Built in isolator IP21C
    Details
  • Key Features: Updated to include choice of tones: Apollo, slow whoop and DIN Two volume settings 92dB(A) and 100dB(A) Synchronisation of tones Individual and group addressing Loop Powered Red or White options IP21C rated
    Details
  • Key Features: Choice of tones on standard device: Apollo, Slow Whoop, and DIN IP66 rated Two Volume settings 92dB(A) and 100dB(A) Synchronisation of 'alert' and 'evacuate' tones Individual and group addressing
    Details
  • Key Features IP 67 rated 'Plug and play' terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
    Details
  • Key Features IP 67 rated 'Plug and play' terminal connections for fast wiring Continuity link for wiring test before commissioning Reports an alarm in under 0.2 seconds Resettable element
    Details
  • Key Features: Uses high intensity LED (white flash only) EN 54-23 Compliant Category W. VAD Coverage W-2.5-7 Automatic LED check when VAD activated Flash rate 0.5Hz Fault signal if LED check failed Locking mechanism (grub screw) Wide angle of visibility Synchronised with the Apollo Protocol
    Details
  • Universal Bracket for the Auto-Aligning Beam Detector. Auto-Aligning Beam Detector Description: The high-performance Auto-Aligning Beam Detector comprises of a ground level controller, detector head with auto-aligning feature, integral laser for rapid initial alignment and single prism. An additional detector head can be added to the controller.  
    Details
  • Key Features: Uses high intensity LED (white flash only) EN 54-23 Compliant Category W. VAD Coverage W-2.5-7 Automatic LED check when VAD activated Flash rate 0.5Hz Fault signal if LED check failed Locking mechanism (grub screw) Wide angle of visibility Synchronised with the Apollo Protocol
    Details
  • The base mounted flame detector bracket combines a bracket and Deckhead Mounting Box.
    Details
  •   Key Features: PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
    Details
  • Key Features: PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Drift compensation Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-7 standard FasTest? for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
    Details
  • Key Features: Dual heat sensors PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
    Details
  • Key Features: Dual heat sensors PureLight optical technology reduces false alarms and enhances smoke recognition Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA devices are connected to an XP95 or Discovery fire control panel.
    Details
  •   Key Features: Dual heat sensors Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
    Details
  •   Key Features: Dual heat sensors Utilises digital CoreProtocol communications Compatible with XP95 and Discovery systems Compatible with existing fire control panels Mechanically compatible with existing bases Available with or without integrated switchable isolator Tri-coloured LED status indicator Polycarbonate moulding for colour stability and strength Comprehensively tested to exceed EN 54-5 standard FasTest for quicker testing of detectors XPERT card addressing or auto addressing Locking mechanism (grub screw) Please Note: Not all features are available when SOTERIA? devices are connected to an XP95 or Discovery fire control panel.
    Details