Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Designed to bring the benefits of laser based aspirating smoke detection to applications where cost would previously have limited installations to ‘point detector in a fan box’ type systems High sensitivity provided by laser based light scatter for reliable early warning Laser smoke sensor chamber specially designed for aspirating detection avoids the airflow problem associated with ‘point-in-a-box’ type solutions Up to 50m of sampling pipe with 10 sampling holes Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laser dust discrimination and elimination system Easy commissioning without the need for a PC
-
Latest generation of universal aspiration smoke detectors 1 or 2 sampling lines with separate sensors and air flow monitoring EN54-20 classes A, B and C Vds certified calculation software; ASD PipeFlow enables efficient, asymmetrical pipe layout 4 alarm levels (3 pre-alarms and 2 alarms) Resolution <0.001%/m Insensitive to pollutants thanks to particle suppression Auto-learning function Low noise level, compliant with ISO 11690-1 Refined smoke detection thanks to HD sensor (high-dynamic technology) Low power consumption High performance suction (>400 Pa vacuum) Individually replaceable
-
Small, low cost aspirating smoke detector for easy and discreet installation High sensitive provided by laser based forward light scatter for reliable early warning Two sampling pipes (100m aggregate) for flexibility Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detector’s operating parameters allowing for day to day changes in the protected environment and the system contamination Unwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system
-
Ultra small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provide by laser based forward light scatter for reliable early warning Signal sampling pipe up to 50m in length Unique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protect environment and dust separation system contamination Unwanted alarm from dust are avoided using patented Dual Technology LDD 3D Laser Dust Discrimination and elimination system
-
Small, low cost aspirating smoke detector for easy and discreet installation High sensitive provided by laser based forward light scatter for reliable early warning Two sampling pipes (100m aggregate) for flexibility Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detector’s operating parameters allowing for day to day changes in the protected environment and the system contamination Unwanted alarms from dust are avoided using patented dual technology LDD 3D laser dust discrimination and elimination system
-
High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
-
Ultra small, low cost aspirating smoke detector for easy and discreet installation High sensitivity provide by laser based forward light scatter for reliable early warning Signal sampling pipe up to 50m in length Unique ClassiFire perceptive artificial intelligent system that dynamically adjusts the detector’s operating parameters, allowing for day to day changes in the protect environment and dust separation system contamination Unwanted alarm from dust are avoided using patented Dual Technology LDD 3D Laser Dust Discrimination and elimination system
-
A fully integrated and compact system, designed for larger pipe networks Designed for use in Honeywell Aspiration Smoke Detection ( ASD) systems Patented design without air resistance (as defined by EN 54-20) 6 user selectable preventive or event-triggered purging programs Internal clock or external clock timer can be connected Several systems can be coupled in Master-Slave mode Manual control via external push-button Automatic initiation if a fault message is received from the ASD system (activating through FACP only) Easy commissioning without software tools Multi-coloured LED indicates the system condition
-
Approved to EN 54-20 in Class A, B and C Provides Very Early Warning Fire Detection, as precise as 0,00095 %/m Five alarm levels and three sensitivity modes provide application flexibility User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption Ultrasonic flow sensing for each pipe inlet and chamber airflow monitoring for precise system health information Dual source optical detection chamber with enhanced algorithms provide high sensitivity with greater immunity to nuisance conditions Easy configuration via USB interface, no external power needed Onboard Ethernet interface enables remote monitoring, configuration, web server and e-mail notifications
-
High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
-
Detection as precise as 0.0015%/m obscuration Integral Ethernet interface enables remote monitoring and e-mail status updates Patented particle separator and field-replaceable filter remove contaminants from the system Five alarm levels & two sensitivity modes Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement Protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions PipeIQâ„¢ software provides intuitive system layout, configuration, and monitoring all in one package Fault indictors covering a broad spectrum of events Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications
-
Approved for use in Class A, B and C, according to EN54-20 Provides Very Early Warning Fire Detection, as precise as 0.00095%/m obscuration Three alarm levels and three sensitivity modes provide application flexibility User configurable 3-speed fan, allowing for maximum coverage area or minimizing on current consumption Patented particle separator removes large, non-fire particulate, ensuring chamber health and extending the life of the field-replaceable filter Easy configuration via USB interface, no external power needed Configurable air flow fault thresholds and verification period Convenient wiring compartment
-
High sensitivity provided by laser based forward light scatter for reliable early warning Unique ClassiFire perceptive artificial intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and system contamination Unwanted alarms from dust are avoided using patented Dual Technology LDD 3D laster dust discrimination and elimination system 4 sampling pipes, up to 250m maximum total length RS485 communications built in as standard for networking and remote communications
-
Photoelectric, integrated low-flow technology Air velocity rating from 1.5m/s to 20.3/sec Versatile mounting options: square or rectangular configuration Broad ranges for operating temperature – 20 to 70 degree and humidity 0-95% (non-condensing) Patented sampling tube installs from front or back of the detector with no tools required New cover temper signal Increased wiring space with a newly added 20mm conduit knockout Available space within housing to accommodate mounting of relay module Easily accessible code wheels on sensor head (sold separately) Clear cover for convenient visual inspection
-
DPK6 for use with Generation6 multi-sensor detectors 850PH and 830PH with built-in 4B-C 4†Continuity Base Designed to comply with EN 54-27 One-pipe air sampling system Patented venturi pipe and duct housing Test hole on cover Simple installation Simple service and maintenance
-
-
Cirrus Pro Series Remote Display Programmer. Multifunction Quarter VGA back lit LCD and programmer. Remote detector ‘Silence’ and ‘Reset’ buttons. May be networked with other Cirrus Pro Series aspirating detectors.
-
1 - 4 Individual detectors per aspirator (providing up to 4 separately identifiable areas) High performance optical ‘Scatter Chamber Detectors’ (SCD) or High performance optical ‘Scatter Chamber Detectors’ (SCD) and enhanced CO detection Multiple language, multi-function LCD display Simple install and commission process without the need for a laptop connection Simple Class A, Class B, Class C and Prison sensitivity configuration set up Inbuilt algorithm to avoid unwanted alarms Airflow monitoring per pipe; Class A - High Sensitivity Applications include: Small Computer Rooms, Cleanrooms, Data Centres, Control Rooms, Archive Storage & EDP areas Class B - Enhanced Sensitivity Applications include: Small Historic Buildings, Museums, Theatres, Galleries, High Ceiling Areas, Small Clean Warehouses & Small Atria Areas Class C - Normal Sensitivity and Harsh Environment Applications include: Lift/Elevator Shafts, Small Cold Storage Facilities, Clean Warehouses, Atria, Inaccessible Voids & Up to 4 x separately identifiable Prison Cells per aspirator.
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four ‘individually identifiable’ sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. Multifunction Quarter VGA back lit LCD and programmer. May be networked with other Cirrus Pro Series aspirating detectors
-
Unique Cloud Chamber Detection Principle Easy to Operate Completely Self Contained Locate potential fire threats from early warning alarms May be used in conjunction with any fixed air sampling system Multi-function LCD Display 10 Sensitivity Settings 4 Alarm Levels Fault diagnostic feature Includes sample probe and battery charger Immune to dust, humidity and temperature changes
-
‘Cloud Chamber’ aspirating fire detector For use with up to a total of 200mtrs of 25mm diameter sampling pipe. Four sampling pipe ‘inlet’ ports, single sampling pipe ‘exhaust’ port. LED status indication of Common Fault, Power, Pre-alarm, Fire 1, Fire 2, Fire 3 alarm conditions Internal buzzer ‘Silence’ button, detector alarm ‘Reset’ Button. Multifunction Quarter VGA back lit LCD and programmer. May be networked with other Cirrus Pro Series aspirating detectors