Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
-
Simple, user friendly design Simple to install Intuitive to use 2, 4 or 8 Zones Walk test Enhanced feature set Multilingual text inserts Designed to comply with EN54 part 2 and part 4
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
2 or 4 zone Twin Wire selection by DIL switch Approved to EN54-2 & 4 3 year warranty as standard Simple colour coded buttons for controls and programming Integral 1 amp switch mode PSU Class change & alert inputs Fire & fault relays 2 monitored sounder circuits Test mode Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
-
2 or 4 zone Twin Wire selection by DIL switch Approved to EN54-2 & 4 3 year warranty as standard Simple colour coded buttons for controls and programming Integral 1 amp switch mode PSU Class change & alert inputs Fire & fault relays 2 monitored sounder circuits Test mode Space for up to 3.2Ah batteries Key-switch or code entry for activation of controls
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable Device options include a full range of smoke detectors (optical, beam and duct types), heat detectors (fixed Temperature or rate of rise types), sounders, strobes and bells Sounder options include shallow base, deep base and bedhead sounder types For installations where a high degree of weather proofing is required, IP55 rated sounders, sirens and bells are available Common accessories such as manual call points (standard IP54 rated or key operated anti-vandal types, available as either surface mounted or flush-fitted models), door release units and Xenon flashers can all be accommodated Spare test keys (for testing manual call points without breaking the glass), spare glasses (packs of 10) and False alarm verification feature to filter out false alarms is selectable through software
-
Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
-
Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
-
Can be used with 2, 4 and 8 zone control panels Internal Power supply Simple unit cabling Up to 3 repeaters per control panel Same modern enclosure as control panels Repeater panel not out of place in public areas
-
2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard Batteries not included; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
-
2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard No batteries included; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
-
Key Features:; Zonal relay card as standard One-man test facility Non-latching zone feature Class change input Fire and fault relays Discreet enclosure; Stylish and compact panel with 6 touch button keypad control of all functions and LED indication Simple one-shot weekly test with auto-reset facility Comprehensive power, fire, and fault LED indicators and integral piezo buzzer for on-board fire or fault indication Battery high/low voltage alarm facility Log book storage facility in front panel
-
Configure zone wiring to work as either a conventional or two-wire system Available in 2, 4 and 8 zone variants Allows the connection of an existing conventional system to a BiWire system Compatible with two-wire and conventional EN 54-23 certified visual alarm devices (VADs) Reduces stock-holding and enables the fire system to adapt to the demands of the customer or application Simple to sell and specify, Flexi can be used in a wide variety of applications and is very simple to install Save time, money and effort when undertaking system extensions and upgrades Up-to-date with latest regulations
-
Facility for signalling to repeater panel provided as standard on 8 zone panel Surface or semi-flush mounting Displays essential information at other key locations in a large building/site Displays zone fire and fault conditions; Repeater matches the style and appearance of the control panel Requires only a single pair of wires to receive signals from control panel reducing cost of installation
-
Cooper FX2208CFCPD Conventional 8 Zone Control Panel; 2, 4 or 8 zones panels Flexible, high specification system Surface or semi-flush mounting Simple "one-shot" auto-reset user test facility Maintenance free poly switch circuit protection, with auto reset Class change and programmable fire/fault relay as standard; Suitable for a large range of projects No fuses required Discreet panel design for incorporation in to any decor Numerical access code (no lost keys) Easy to maintain/service
-
2,4 & 8 Zone 2 wire versions available in an aesthetically pleasing design. Uses Fulleon 2 wire sounder (models: Squashni sounder & sounder/beacon base, Symphoni sounder) Uses resistor & zener diode EOL device, (no resistor only option as with standard panel) Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access (no ‘user confuser’ codes!) Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 standard sounder circuits 4 & 8 zone, 2 on 2 zone panel (as well as zone sounders) Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only)
-
Fike Ocelus Conventional 2 Zone Fire Panel – 500-0002; Access via password – removes the problem of lost keys One man walk test facility Disablement facility for zones & sounders Space for up to 3Ah batteries Sounder delay option 4 sounder circuits Sounder circuits 3 and/or 4 can be configured as Aux 24V supplies
-
-
2,4 & 8 Zone versions available in an aesthetically pleasing design. Sturdy, flame retardant, ABS plastic enclosure with controls, zone text insert and indications overlay Easy to install, program and use. Key operated controls access Panels can be surface or semi flush mounted and have 20mm cable gland breakouts Comprehensive LED indications and user/engineer controls Low standby power consumption 4 Sounder circuits 4 & 8 zone, 2 on 2 zone panel. Zonal & Alert sounder options configurable 1.5A switched mode power supply with temperature compensated battery charging Enclosure houses 3.4Ah SLA batteries as standard 8 Zone repeaters available with 24V or mains operation (suitable for 4 & 8 zone panels only) Short circuit zone activation option (Global) End of Line zone resistor option for retrofitting (Global)
-
Fully approved. Optional extinguishment module EN12094-1 approved. 8 zones mainboard. Supports 2 J400-EXP8 expander modules, total 24 zones. Up to 32 devices can be connected to each zone. Gas zone compatible with 4 – 20 mA gas detectors. One alarm-repeat output for each input zone. Manual call point recognition. Signals missing detectors. 2 supervised, silence able, bypass able 24 V alarm output for sirens and activation. Silence able fault warning output for the activation of signalling and auxiliary devices. Supervised fire output for telephone dialler activation. Programmable open-collector output. Dry contact alarm-relay for the activation of auxiliary devices. Day/Night mode. Alarm verification time. Programmable restoral and reset times. Programmable from PC or keypad. 50 event log viewed via PC. Alarm/fault memory activated until next reset. Command for silencing sirens. Keypad commands require key or pin code. Repeater available. Optional backlit display.
-
EN54 approved Optional extinguishing module EN12094-1 approved 8 zones mainboard Supports 2 J400-EXP8 expander modules, for total 24 zones Up to 32 devices can be connected to each zone Gas zone compatible with 4-20 mA gas detectors One alarm-repeat output (open collector) for each input zone Manual call point recognition Signals missing detectors 2 supervised, silence able, by passable 24 V alarm output for sounders Silence able fault-warning output for the activation of signalling and auxiliary devices Supervised fire output for telephone dialler activation Programmable open-collector output Dry contact alarm-relay for the activation of auxiliary devices Day/Night mode Alarm verification time Programmable restoral and reset times Programmable from PC or keypad 50 event log viewed via PC Alarm/fault memory activated until next reset Command for silencing sirens Keypad commands require key or pin code Repeater available Optional backlit display