-
20 programmable zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 Serial Port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility. Graphical display configurable for virtually any language. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13
-
Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
20 programmable zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 Serial Port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility. Graphical display configurable for virtually any language. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13
-
20 programmable zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 Serial Port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility. Graphical display configurable for virtually any language. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13
-
Vigilon’s advanced sensing technology and powerful software processing in the panel quickly identifies real fires PC based commissioning tools allow complex fire plans to be configured Advanced loop card technology allows system status monitoring and diagnostics The control panel has a simple user interface with LCD screen providing accurate information in an emergency Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required Supplied with batteries
-
Integral EN54-4 PSU and battery standby for 24 hours (4 loop panel only) Integral EN54-4 PSU for 72 hours with external batteries (6 loop panel only) Vigilon’s advanced sensing technology and powerful processing in the panel quickly and identifies real fires PC based commissioning tools allow complex fire plans to be configured Advanced loop card technology allows for system status monitoring and diagnostics The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Extended event log using flash memory card
-
PC Software:; Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dual flash-based microprocessor technology with real-time clock on-board. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facilities for ease of commissioning and fault finding. Graphical display configurable for virtually any language Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. Fully programmable via the on-board alphanumeric keypad, or PC configuration tools. Integral ‘P-Bus’ for system expansion via available option cards Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13
-
Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supporting industry leading protocols: Apollo, Hochiki ESP and System Sensor Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
Integral EN54-4 PSU and battery standby for 24 hours (4 loop panel only) Integral EN54-4 PSU for 72 hours with external batteries (6 loop panel only) Vigilon’s advanced sensing technology and powerful processing in the panel quickly and identifies real fires PC based commissioning tools allow complex fire plans to be configured Advanced loop card technology allows for system status monitoring and diagnostics The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Extended event log using flash memory card
-
Integral EN54-4 PSU and battery standby for 24 hours (4 loop panel only) Integral EN54-4 PSU for 72 hours with external batteries (6 loop panel only) Vigilon’s advanced sensing technology and powerful processing in the panel quickly and identifies real fires PC based commissioning tools allow complex fire plans to be configured Advanced loop card technology allows for system status monitoring and diagnostics The control panel has a simple user interface with LCD screen providing accurate information in an emergency Multiple panel networks can be programmed seamlessly as one system, allowing for flexible design and system management Flexible programming options are available at the panel All Vigilon devices connect onto the same two core loop, separate sounder or repeater panel wiring circuits are not required In the event of a fire or fault, Vigilon’s analogue addressable technology will provide a detailed log of events Extended event log using flash memory card
-
-
Key Features:; Single Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 260 x 390 x 147mm (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
Key Features:; Two Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
Key Features:; Four Loop Control Panel, 230Vac, 2 sounder circuits. Supports the Morley-IAS protocol Dims 391.5 x 390 x 147 (H x W x D) Network up to 16 loops (16x1 loop panels, 8x2 loop panels, 4x4 loop panels or any mix up to max 16 loops) True peer-to-peer and fault tolerant network for high system reliability BS5839 part 1 compliant network Disable all relays Easy 5 key-press set-ups Large blue LCD display Supports USB upload/download Alpha-numeric style keypad and navigation keys Option to upload a company logo 160 zone compact mimic support Panel buzzer ‘mute’ in engineering mode Up to 72-hour standby
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution* protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
20 programmable Zonal / 25 System LEDs. Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones Approved to BS EN54 part 2, 4 and 13.
-
With A compact enclosure (380mm x 365mm x 110mm) and a single PCB with on-board power supply (1.5A), the ID60 provides the user with an easy to install/maintain Fire Alarm System.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
-
All major device manufacturers devices supported Optional, local or remote printers Walk test facility Provide up to 72hr stand-by (subject to verification) Supporting a total of five industry leading protocols, Apollo, Hochiki ESP, Nittan, Morley-IAS and System Sensor Simple, robust design to EN54 Parts 2 & 4 Facility to print history and event logs Report & Control System - For multiple building sites where information is presented at the local and master panels only 99 panel network allows systems in excess of 60,000 devices to be managed
-
The ID61 is housed in a slightly larger enclosure (500mm x 400mm x 110mm) than the ID60 to accommodate for an internal mounted printer. A larger separate power supply (3A) is fitted in the ID61 to cater for the more power hungry applications.; LPCB approved to EN54 Parts 2 and 4 One loop capacity (99 sensors and 99 modules) 16 fire zones, 16 non fire zones Supports advanced detection such as VIEW™ HARSH™ OptiPlex HAZARD™ 64 CBE rules 10 Pre-alarm levels per sensor 9 Alarm levels per sensor Drift compensation Maintenance alert Automatic High Test Day / Night mode facility Time programs Class Change “Autolearn” facility One man “walk test” 2 x 40 character backlit LCD Active and passive repeaters Programmable from the panel keypad or PC Supports loop powered sounders & relays Two on board sounder circuits Two on board configurable outputs
-
Fully expandable from 2 - 8 loops via plug-in loop driver boards. 20 programmable Zonal / 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dual flash-based microprocessor technology with real-time clock on-board. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. Fully programmable via the on-board alphanumeric keypad, or PC configuration tools. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. 2 x 5 Amp power supply and charger to En54 part 4. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones.
-
Fully expandable from 2 - 8 loops via plug-in loop driver boards. 20 programmable Zonal / 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dual flash-based microprocessor technology with real-time clock on-board. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. Fully programmable via the on-board alphanumeric keypad, or PC configuration tools. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. 2 x 5 Amp power supply and charger to En54 part 4. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones.
-
Key Features:; Fully expandable from 2 - 8 loops via plug-in loop driver boards. 20 programmable Zonal / 25 System LEDs with slide-in labels. Dedicated loop driver for Apollo or Hochiki protocol support. Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware. Dual flash-based microprocessor technology with real-time clock on-board. Dedicated USB & RS232 serial port for direct PC or modem connection. Installer friendly Auto-learn, Loop Detection and On-board Scope facility for ease of commissioning and fault finding. Fully programmable via the on-board alphanumeric keypad, or PC configuration tools. The graphical display can be configured to operate with virtually any language or character set, and allow the installer's logo to be applied using the Logo application software. Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination. 2 x 5 Amp power supply and charger to En54 part 4. Integral P-Bus for system expansion via available option cards. Ad-NeT peer-to-peer network with up to 2000 zones.
-
Compatible with all Morley-IAS intelligent multiprotocol fire alarm control panels Connects to RS485 peripheral bus Active or Passive options Backlit adjustable alphanumeric display General status LEDs Controls for system reset, accept, mute, silence alarms, and self-test (active repeater only) “Access Enable” key-switch on active repeater